PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE TURNING ON THE STERILISER FOR THE FIRST TIME
Specifically developed for sterilising grooming instruments, the
Vivog ES018 represents the latest generation of UV light
sterilisers. The steriliser sterilises grooming instruments to
99.9%.
It is composed of a high quality body in plastic injected and of
an interior aluminium box with high thermal efficiency thus
improving the output of thermo-electric resistance and the
reflexion-refraction of the ultraviolet ray lamp.
Important: please follow the guidelines for use
SAFETY PRECAUTIONS
- Make sure that the steriliser is placed on a strong, solid, flat surface.
- The power cable of the steriliser should be unplugged from the wall
socket whenever the machine is not in use.
- Check that the voltage indicated on the plate corresponds to your
electrical supply. Your electrical supply should meet current safety
standards and be fitted with a 30 mA circuit breaker.
- The steriliser should be installed in a dry and well ventilated site.
- Never submerge the steriliser in water and never use in wet places.
- If the steriliser falls into water, unplug it from the power supply
before touching it.
- Never use the steriliser if it is dropped into water: take it to the
VIVOG technical assistance centre for inspection and repair if
necessary:
VIVOG SAS
2 Rue de la Briaudière
- BP 4000
1
37515 BALLAN-MIRÉ CEDEX - FRANCE.
Tel.: +33 (0)2 47 73 38 38 – Fax. +33 (0)2 47 73 38 48
E-mail: [email protected]
- If the steriliser stops working or does not work correctly, turn it off
and do not open it. Repairs should only be performed at the VIVOG
technical assistance centre.
- If the power cable is damaged, it should be replaced with an identical
model.
- Never use the steriliser if it is damaged or if there are missing parts.
- Never use the steriliser with wet hands or feet.
- Never use the steriliser barefoot.
- Never use the extension lead in rooms that are destined for bathing or
showering.
- Never pull the power cable or the steriliser to unplug it from the
power socket.
- Never allow children or unskilled persons to use the steriliser without
supervision.
- Never open the door of the steriliser without making sure that it is
turned off.
- Never use the steriliser for anything other than the purpose for which
it is designed.
- This machine is not designed to be used by people (including children)
whose physical, sensory, or mental capacities are reduced, or by anyone
without the necessary skills or knowledge, unless they are specifically
monitored or have been instructed in the use of the machine by
somebody responsible for their safety"
- Children should be monitored to ensure that they do not play with the
machine.
NEVER OPEN THE MACHINE
Use:
- Make sure that the steriliser is stable before operation. The steriliser
should be turned off before opening the door.
- Only use the cable supplied and plug it into an electric socket that
complies with current regulations.
- Instruments should be cleaned and dried before being placed in the
steriliser.
- The “4-in-1” OPTIMUM spray is ideal for cleaning the instruments
prior to sterilisation (optional extra).
All optional extras are available from your reseller or on request by e-
mail from [email protected].
- Place the cutting instruments on the steriliser making sure that they
are not overlapping one another, and making sure that all scissors are
opened.- Close the door
- Press the ON/OFF button to start the steriliser. The light comes on,
indicating the start of the programme.
- Sterilisation only begins once the door is closed. It stops
automatically as soon as the door is opened.
- The programme takes 25 minutes. At the end of the cycle, turn the
steriliser off.
- Press the ON/OFF button to turn off the power supply and remove the
cutting instruments.
Cleaning and maintenance:
- Before cleaning or replacing the light bulb, turn off the steriliser and
remove the plug from the power socket.
- Use a soft damp cloth to clean the inside of the steriliser.
- Do not use inappropriate cleaning products (creams, solvents,
abrasive products, etc.).
Technical specifications:
- External dimensions (Lxhxdepth):
35 x 22 x 21 cm
- Net weight:
6 Kg - 220V - 50 Hz – 185 W - Capacity : 13 L
- Inner temperature : 40°C +/- 10°C
Guarantee;
The steriliser is guaranteed for a period of 12 months from the date of
purchase, the guarantee terminates at this time even if the steriliser has
not been used. It is therefore advisable to keep the proof of purchase
(receipt and original packaging).
The guarantee is applicable for normal conditions of use and not
intensive, on clean materials with regular maintenance of the steriliser.
The guarantee covers all mechanical and electrical manufacturing
defects.
The replacement or repair of parts subjected to normal wear, such as
the UV light, are therefore excluded.
Any repairs made during the guarantee period do not result in a
prolongation of the latter.
The guarantee is not valid if the steriliser has been opened or damaged
as a result of negligence, inexperience, or during transport.
The replacements or repairs covered by the guarantee are free of charge
by sending the steriliser directly, in its original packaging, with proof
of purchase to:
VIVOG SAS
2 Rue de la Briaudière
- BP 40001
37515 BALLAN-MIRÉ CEDEX - FRANCE.
Tel.: +33 (0)2 47 73 38 38 – Fax. +33 (0)2 47 73 38 48
E-mail: [email protected]
Shipping costs are at the expense of the purchaser.
Use: worktop
VIVOG SAS
2 Rue de la Briaudière – CS 40001
37515 BALLAN-MIRE CEDEX – FRANCE
tel. +33 (0)2 47 73 38 38 - fax. +33 (0)2 47 73 38 48
email : [email protected]