(c) Keep holding down the page button for approx. 10 sec until a “Beep” tone is heard, which 
indicates that all previously registered handsets are erased from that base unit and the base 
registration entry is now empty 

To selectively de-register a handset at the base-station 

1.

 

Handset unit is in standby mode 

2.

 

Enter the code HOLD 

 “ # # # 7” 

 HOLD on the handset 

3.

 

A long “beep” tone indicates that the handset has de-registered itself at the base-station 

J.

 

DECT Handset Setup Menu 

We provide an interface for technicians to enter parameters on the handset such as clock display info, 

ringer tone, and to active DECT registration and de-registration. Details below.  

(I)

 

To acceess the setup menu on the DECT handset 

1.

 

Enter the code, “# 0 8 8 HOLD” in idle state / standby mode. 

2.

 

Hear a short “beep” tone 

3.

 

See that you are in the first level of the setup menu 

(II)

 

To navigate the setup menu on the DECT handset 

Use the “VOL+“ and “VOL-” buttons for going up and down the menu, respectively. 
Press “HOLD” key for confirmation of selection or changes made. 

Press “On-hook” key, 

  to exit the menu. 

(III)

 

Content of the setup menu on the Handset 

First Level 

Second Level 

Third Level 

Definition / Description of Setting 

Date & Time 

 

 

Date and Time settings 

Time Format   

 

12hr / 24hr display format setting 

C. Log Timer 

 

 

Set the time lapse for the call log to be 
automatically erased – 10 mins / 30 mins / 24 
hours / off 

Show Clock 

 

 

Enable/ disable the real time clock display during 
standby mode 

HS setup 

Contrast 

 

Adjust the 6 levels of LCD contrast 

 

Handset Tone 

Ring Volume 

Customize 3 levels ringing volume 

 

 

Ring Melody 

Choose any of the 16 ringing melody 

 

 

Key Tone 

Choose to play tone or melody or no tone at all 

Содержание V656IPW

Страница 1: ...Hot Keys WAN port and LAN port Headset connectivity check with your distributor for this option before order PoE check with your distributor for this option before order Server Compliance Asterisk Broadsoft Alcatel NEC Avaya basic call features supported Codecs and Voice Features Wideband codec G 722 Narrowband codec G 711μ A ILBC G 729 VAD CNG AEC PLC AJB AGC Full duplex speakerphone with AEC ...

Страница 2: ...2 16 A Handset Key Mapping and Description Diagram above shows the keypad mapping on the wireless handset of V656IPW ...

Страница 3: ...Description PAGE To page to locate the wireless handset R Call Flash VOL To decrease loudspeaker volume on the base station VOL To increase Loudspeaker volume on the base station HOLD To put a call on hold REDIAL Last Number Redial SPK Speakerphone ON OFF Toggle H0 M3 Hidden Keys for Technician M0 M9 Pre programmable Memory Keys ...

Страница 4: ...te the hands free function i e speakerphone mode 6 To drop the call temporarily and make another call press the flash button 7 To end the call place the handset back on the cradle or press the On hook button Using the base unit speakerphone 1 Press speaker button SPK The red LED indicates that the speaker is active 2 Listen to the dial tone 3 Press the desired number or press a memory button for a...

Страница 5: ...off IV Direct Memory Dialling Using the wireless handset 1 Lift the handset Press the M1 button to dial the pre stored number from the direct memory 2 To end the call place the handset back on the cradle or press the On hook button Using the base unit speakerphone 1 Press the desired memory button one of the ten memories on the base unit The red LED indicates that the speakerphone goes active auto...

Страница 6: ...a single key press action In the event of a new incoming message the MSG button lights up to alert users Simply press the MSG button on the base unit or the handset The base unit goes off hook and dial to retrieve the message from the mail box automatically Please see section for memory programming guide G WebPortal Phone Setting Guide The Web Portal of V656IPW can be accessed by Google Chrome Int...

Страница 7: ...ss When prompt for login enter admin for user name admin for password Adminstrators enjoy full access to all configurations and actions important to phone settings Firmware upgrade SIP registry settings are only available to administrators II To Logout When done remember to logout completely Clear the cache cookie of your web browser so that the previous login is not re cycled by the next user III...

Страница 8: ...link and press on it 3 Enter username for login name 4 Enter password and re enter for confirmation purpose 5 When the mask password box is checked both password entries are masked To un mask simply un checked the mask password box Figure 2 Set Password for the Web Portal ...

Страница 9: ...lways preserve the changes and decide to restart the phone at a later time Figure 3 Network Settings page on Web Portal V SIP Account Settings Parameters for Session initiation protocol SIP such as registrar address proxy address port etc can be found in the SIP Accounts section on the Configuration page 1 Go to Configuration page 2 On the left panel click Register 3 A dropdown menu appears Click ...

Страница 10: ...eactivation Auto Answer activation deactivation Parameters for network environment such as Network Address Traversal NAT can be found under SIP NAT Settings Parameters for Audio settings for each account can be found under the title Audio Settings on the left panel Such parameters include DTMF mode in band RFC2833 SIP INFO Audio Codec preference PCMU PCMA G 722 G 729 iLBC ToS Jitter When done with...

Страница 11: ...ry to store M1 and MSG The 10 memory keys can be pre programmed in the Configuration page Memory Key 9 is reserved for MSG See Section B Base Unit Key Mapping Figure 5 Memory key and MSG button settings page on Web Portal ...

Страница 12: ...s the HOLD button again v A long Beep tone indicates that the handset has entered the registration mode and it s searching for the base unit vi An audible tone can be heard upon successfully registration vii Press the On button to get a line and hear the dial tone I DECT Handset De registration Each base unit is capable of registering a maximum of 4 handsets When the base registration entry is ful...

Страница 13: ...8 HOLD in idle state standby mode 2 Hear a short beep tone 3 See that you are in the first level of the setup menu II To navigate the setup menu on the DECT handset Use the VOL and VOL buttons for going up and down the menu respectively Press HOLD key for confirmation of selection or changes made Press On hook key to exit the menu III Content of the setup menu on the Handset First Level Second Lev...

Страница 14: ...ture Auto Answer refers to the action taken by the handset to enter the dialing state as soon as it leaves the charging cradle Handset Name Set the name to be displayed on the idle screen Language Default display language is English Register Enable the DECT registration mode Default Restore to factory default settings ...

Страница 15: ...ECT REASSEMBLE CAN CAUSE ELECTRIC SHOCK WHEN THE APPLIANCE IS SUBSEQUENTLY USED 9 UNPLUG THIS PRODUCT FROM THE WALL OUTLET AND REFER SERVICING TO QUALIFIED SERVICE PERSONNEL UNDER THE FOLLOWINGCONDITIONS WHEN THE POWER SUPPLY CORD OR PLUG IS DAMAGED OR FRAYED LIQUID HAS BEEN SPILLED INTO THE PRODUCT IF THE PRODUCT HAS BEEN EXPOSED TO RAIN OR WATER 10 IF THE PRODUCT DOES NOT OPERATE NORMALLY BY FOL...

Страница 16: ...16 16 HTI PRODUCT SUPPORT Should you need any technical assistance for this product please contact Hotel Technology International Limited Telephone 44 0 203 405 1200 Email support hotel tech com ...

Отзывы: