MountingSet Inwall zero square
Incl. MountingSet flush mount frame with reinforcing grid
REV20180809
Installation in brick walls and concrete walls (shell)
Make an angular opening in the wall: Measurements for portrait: 271mm length, 344mm height. Measurements for
landscape: 344mm length, 271mm length. The depth should be approximately 76mm. Place the power cable.
Apply subsoil / substrate plaster to the wall and fix the flush mount frame - pay attention that the flush mount box is
fastened parallel to the surface and is not shifted or offset in the wall.
! Important: The subsoil / substrate plaster must provide a very smooth, surface adhesion for the flush mount frame,
stress- and distortion-free!
Incorporate the flush mount frame with approved embedding material (see above). To do this, prepare the surface
according to VOB, Section C, DIN 18363, DIN 18350 or BFS notices. Then apply the embedding material evenly to the
gypsum fibreboard according to the manufacturer's instructions. Embed the reinforcement fabric of the frame in the wet
coating without any creases. After that apply embedding material again evenly, so that the grid is no longer visible.
Depending on the design ideas the flush mount frame can be plastered up to the upper edge.
After the embedding material has perfectly dried out, please clean the inner surfaces of the frame. Insert the wall case /
flush mount box and fix it with fastening material such as plaster or mortar or cement – Please follow the installation
guide for the MountingSet Inwall.
! Attention: Install the flush box so deep that it rests firmly on the inner ring of the frame.
! Attention: Screw the wall case / flush mount box so tight that it stabilizes the frame.
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von