7URXEOHVKRRWLQJ
code
malfunction
Error display
Repair method
code
malfunction
Error display
Repair method
Dual 8
display
LED
Dual 8
display
LED
1
Storage slug
EE
Heating
LED-pause 3s
and blink 15
times
Replace indoor main board
15
Sync failure
H7
Heating
LED-pause 3s
and blink 7
times
Check if the resistance of compressor
and resistance to ground is normal. If
the
compressor is normal, the outdoor
main boar d may be wrong.
2
Indoor PCB
malfunction
EE
Heating
LED-pause 3s
and blink 15
times
Replace indoor main board
16
Current diction
malfunction of
complete unit
U5
Cooling
LED-pause 3s
and blink 13
times
Replace outdoor main board
3
Anti-freezing
protection
E2
Running LEDpause
3s and
blink 2 times
Outdoor ambient temperature is
too low
17
Outdoor ambient
temperature sensor
malfunction
F3
Cooling
LED-pause 3s
and blink 3
times
Is it loose? Measure the resistance
value
with universal meter
4
Overload of
system
H4
Heating
LED-pause 3s
and blink 4
times
System is abnormal, check if the
evaporator and condenser is
dirty and blocked
18
Discharge
protection of
compressor
E4
Running
LED-pause 3s
and blink 4
times
Is it loose? Measure the resistance
value with universal meter
5
No motor of
indoor unit
feedback
H6
Running LEDpause
3s and
blink 11 times
Is electromotor mounted normally?
19
Break-circuit and
short-circuit of
outdoor discharge
temperature sensor
F5
cooling LEDpause
3s and
blink 5 times
Is it loose? Measure the resistance
value
with universal meter
6
Indoor pipe
temperature
sensor
malfunction
F2
cooling LEDpause
3s and
blink 2 times
Is it loose? Measure the resistance
value with
universal meter
20
Break-circuit and
short-circuit of
outdoor condenser
temperature sensor
F4
cooling LEDpause
3s and
blink 18 times
Is it loose? Measure the resistance
value with universal meter
7
Internal ambient
temperature
sensor
malfunction
F1
Cooling LEDpause
3s and
blink 1 times
Is it loose? Measure the resistance
value with
universal meter
21
Overheat of carbon
P8
heating LEDpause
3s and
blink 19 times
Is outdoor ambient temperature is too
high? Is radiator mounted correctly?
8
Zero passage
abnormal
UF
Heating and
cooling LED
blinks 7 times
at the same
time
Replace indoor main board
22
DC overcurrent
H5
Heating LED blink 5
times
9
Overload of
compressor
H3
heating LEDpause
3s and
blink 3 times
Inspect connection state of the
overload wire.
23
Temperature
sensor malfunction
P7
heating LEDpause
3s and
blink 18 times
Replace outdoor main board.
10
Startup failure
Lc
heating LEDpause
3s and
blink 11 times
Check if the resistance of
compressor and resistance
to ground is normal. If the
compressor is normal, the
outdoor main boar d may be
wrong.
24
Lack of Freon or
block protection
F0
cooling LEDpause
3s and
blink 10 times
11
No motor of
outdoor unit
feedback
UH
Heating and
cooling LED
blink 8 times
at the same
time
This malfunction may happen
when outdoor DC electromotor is
used.
25
DC input voltage is
too high
PH
cooling LEDpause
3s and
blink 11 times
Is voltage of AC power supply normal?
12
Over current
protection
E5
Running LEDpause
3s and
blink 5 times
Is electric network
variable?
26
DC input voltage is
too low
PL
Heating LEDpause
3s and
blink 21 times
Is voltage of AC power supply normal?
13
4-way valve
conversion
abnormal
U7
cooling LEDpause
3s and
blink 20 times
Replace 4-way valve.
27
Communication
malfunction
E6
Running LEDpause
3s and
blink 6 times
Is outdoor connecting wire reliably
connected?
14
Phase current
detection
malfunction of
compressor
U1
Heating LEDpause
3s and
blink 13 times
Replace outdoor main board.
28
Setting error, indoor
and outdoor unit
abnormal
UA
Heating and
cooling LED
blink 12 times
at the same
time
Outdoor unit is not matched with
indoor unit.
remar
ks
4min after protection stop of compressor, the malfunction is shown in error code. In other situation, the malfunction will be displayed by press the light button for 6 times within 4s.
Содержание ACP-12CH35GECI
Страница 1: ...ACP 12CH35GECI ACP 18CH50GECI Service manual ENG RoHS NNO 1 09 ...
Страница 2: ......
Страница 46: ... SORGHG 9LHZV DQG 3DUWV LVW 3 2 26 28 22 21 20 19 17 18 14 13 12 11 10 9 8 7 6 5 4 3 2 1 24 23 27 16 15 25 ...
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......