10. Keeping the null indicator on the vertical line, walk toward the arrow. 
11. A Sonde icon will soon appear (Note that the arrow is not shown when the sonde icon appears). Keeping the locator vertical, carry on 

walking toward the Sonde until it is positioned on the crosshairs. The locator is now directly over the Sonde. Note that the depth of 

the sonde is also displayed. 

 

 

12. The diagram below provides an overview of the process: 

 

Overview 

 

13. Note that when directly over the Sonde, it may be necessary to confirm the position of the Sonde, left to right. Do this by moving the 

locator left to right to identify the location of the strongest signal, as indicated on the bar graph. At this time, the depth to the Sonde 

will be displayed at the top of the display. 

14. Having pinpointed the position of the Sonde/camera head, it can now be pushed into a new location, and the process repeated. It is 

advisable to keep the survey intervals too short distances such as six feet (two meters) as this makes the process of locating easier. 

 
 
 
 
 
 

Vivax-Metrotech Corp. (Headquarters) 

3251 Olcott Street, Santa Clara, CA 95054, USA 

 

T/Free: 800-446-3392 

Tel: +1-408-734-1400 

Email: [email protected] 

Website: www.vivax-metrotech.com 

 

Visit us at

 

www.vivax-metrotech.com

 

to view our full product line and worldwide locations. 

 

Содержание VM-550FF

Страница 1: ...used The locate frequency is applied by direct connection or induction For this application the direct connection method must be used VM 550FF What s in the box 1 VM 550FF Transmitter 2 Ground stake...

Страница 2: ...cell alkaline batteries 5 Alkaline battery tray 6 Mini USB lead Loc3 5Tx Connections Block 1 Connection lead socket 2 Fuse 1 6A 250V Fuse 3 Loudspeaker 4 Battery charging socket DC input Loc3 5Tx Keyp...

Страница 3: ...ood choice of a transmitter providing 83kHz at 1 watt of power However any transmitter with a high direct connection frequency over 65kHz is suitable for the task Peak Response Mode The Line mode used...

Страница 4: ...n the transmitter If 83 1kHz is not available on the transmitter select 65kHz or 32 8kHz 4 Insert the pushrod into the pipe and push in at least 5m 15ft of the pushrod cable less than this may not pro...

Страница 5: ...the pushrod cable until a maximum Peak signal is obtained It may be necessary to reduce or increase the sensitivity to keep the bar graph on the scale This is normal and should be expected Try to kee...

Страница 6: ...key to enter the sonde mode The sonde and omni peak icons will appear in the upper left corner of the LCD 3 Use the f key to select the sonde frequency matching frequency of the control module Tip Us...

Страница 7: ...ition of the Sonde left to right Do this by moving the locator left to right to identify the location of the strongest signal as indicated on the bar graph At this time the depth to the Sonde will be...

Отзывы: