1     General Safety & Care Information

1.   General Safety Instructions

1.1  Before using for the first time, please read the following carefully:

• 

In general, the vCamLSR can be used indoors and outdoors. (

Do not

 operate with a mains input in wet conditions.)

• 

To ensure safety and reliable operation – 

do not

 subject this unit to extreme temperatures, shock or impact.

• 

Avoid getting moisture/water inside the enclosure.

• 

To avoid the risk of electric shock, 

do not

 open the sealed enclosure.

• 

Nickel metal hydride (Ni-MH) rechargeable batteries pack.

 

Do not

 remove or attempt to access the rechargeable batteries.

 

Use only specified charger for the rechargeable batteries. Use of an incorrect charger could result in damage to the 
vCamLSR control module or excessive over-heating.

 

Do not

 damage, crush or puncture batteries or subject to extreme heat or fire.

 

Dispose of these batteries in accordance with your company’s or organization’s procedures.

• 

Storage temperature: -20

to +70

 (-4

o

F to 158

o

F).

• 

Operating temperature: -10

 to +50

 (14

o

F to 122

o

F).

1.2  Care of Equipment 

• 

Use the camera system to inspect pipes and not to clear obstructions. If the camera head is underwater or its view     
obstructed by debris, stop and clean out the pipe first.

• 

Use equipment only as directed in this user handbook.

• 

 

Do not

 immerse any part of this equipment in water.

• 

Store in a dry place.

• 

Keep equipment in the case provided when not in use.

• 

If left for prolonged period of time – remove alkaline batteries.

• 

Keep unit clean and free of dust and dirt.

• 

Protect against excessive heat.

• 

Protect the pushrod, camera head and termination parts by cleaning often and not letting dirt and debris dry on it.

• 

Keep the control module or viewer a safe distance from the point of entry to avoid splash back.

• 

Use the provided “insertion sleeve” to prevent chafing and scraping of the pushrod jacket when deploying the pushrod  
in pipes and ducts.

• 

Use caution when cleaning the LCD cover to avoid scratching it.

• 

Use low-pressure water to rinse off the termination parts after use and user air to blow off excess water.

• 

 

Do not

 let dirt dry on the pushrod, termination parts or camera head.

• 

Use only the correct size and voltage fuse.

• 

 

Do not

 use power washers to clean the equipment. Use low-pressure water on the pushrod or termination parts.

• 

If the pushrod conductors are exposed, stop using the pushrod immediately.

• 

When the control module is mounted on top of the reel, 

do not

 use the control module as a handle to move the reel.

1.3  Health and Safety

This equipment is primarily used for the inspection of sewer pipes, by professionals operating in the sewer and plumbing 
industry, and maintained by professionals familiar with the health risks of maintaining equipment that has been in a sewer.

Such professionals will be protected by their own company’s recommendations and work practices. If for any reason they are 
not, or are not familiar with such practices, please check our website or email [email protected] for a copy of the Health and 
Safety Document used by Vivax-Metrotech for employees involved in the demonstration, maintenance and handing of sewer 
camera systems.

Page 1 of 15

Содержание vCamLSR

Страница 1: ...vCamLSR User Handbook English Edition Version 1 4 P N 4 04 000066...

Страница 2: ......

Страница 3: ...nd Held Viewer Overview 5 3 5 Reel Overview 6 4 Setup 7 4 1 Installing Batteries in the Viewer 7 4 2 Connecting the Viewer to the Reel 7 4 3 Installing and Removing the Pushrod Camera Heads 8 5 Using...

Страница 4: ...6 Using a vCam 5 Control Module...

Страница 5: ...Keep unit clean and free of dust and dirt Protect against excessive heat Protect the pushrod camera head and termination parts by cleaning often and not letting dirt and debris dry on it Keep the con...

Страница 6: ...ow traffic control regulations Use personal protection such as eyewear rubber gloves and non skid safety shoes Do not use the control module as a handle to move the reel Remove the control module or u...

Страница 7: ...ott Street Santa Clara CA 95054 USA Website www vivax metrotech com T Free 800 624 6210 Tel 1 408 734 1400 Fax 1 408 743 5597 Email VentasparaAmericaLatina vxmt com China Leidi Utility Supply Shanghai...

Страница 8: ...sual inspection of small pipes ducts cabling systems process plants machinery behind dry walls in ceilings and any other similar structures 3 2 System Components The basic system is supplied with Page...

Страница 9: ...vCamLSR system has its own model and serial numbers at the back of the hand held and also one on the cable reel assembly 3 4 Hand Held Viewer Overview The features functions and controls of the hand...

Страница 10: ...3 Introduction 3 5 Reel Overview Page 6 of 15 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 11: ...batteries into the battery compartment 3 Close the lid and tighten the thumb screw by turning it clockwise until tight 4 2 Connecting the Viewer to the Reel To bring the video to the hand held viewer...

Страница 12: ...r in the field Both camera heads are screw on types so no tools are needed To remove a camera head Hold the spring assembly firmly just behind the camera head Screw the camera head counter clockwise u...

Страница 13: ...r s display can be adjusted for use in different lighting situations Camera LED Light Setting Aftermarket Flexible Rod Camera Only Press pushbutton once to bring up the Video Light setting menu Press...

Страница 14: ...setting menu Press the left right buttons as needed to raise and lower the screen saturation on a scale of 0 to 100 5 3 Focus the Camera The D25 D camera is a manual focusing camera The D25 D camera...

Страница 15: ...f the pushrod is back in the drum remove the rod from the cable guide 3 Position the camera and spring assembly back into the drum 4 Return the drum brake to the locked position 5 5 Locating the Posit...

Страница 16: ...change when the Sonde or unit is turned off Press and hold the Sonde button while in Sonde mode to change the frequency again The best practice for locating the camera Sonde is to push the camera into...

Страница 17: ...Insert the plug into the control module socket and release the knurled ring Check that the connection is secure by giving a slight wiggle and tug To remove the interconnect cable pull back the knurle...

Страница 18: ...e Reel Settings Update About File Type CP Type M M2 Type C Type P Type S Setup NOTE The distance counter is for reference only It is important that you verify the actual position and depth with a Sond...

Страница 19: ...etrotech com Illustrations used in the preparation of this manual will inevitably show some resemblance to similar illustrations from other Manufacturers some manufacturers have given permission for t...

Отзывы: