2 - INSTALLATION OF YOUR OVEN
Electrical Connection and Security
1.
Your oven is adjusted in compliance with 230 Volt 16 Ampere electric supplies. (For 3 phase 230V/400V
32 Ampere) If the mains is different from these values, contact your authorized service.
2.
Electrical connection of the oven should only be made by the sockets with earth system installed in
compliance with the regulations. If there is no proper socket with earth system in the place where the oven
will be placed, immediately contact a qualified electrician. Manufacturer shall never be responsible from the
damages that will arise because of the sockets connected to the appliance with no earth system.
3.
Electrical cable should not touch the hot parts of the appliance.
4.
Some models are supplied without a plug-an-lead set. In this case please use a flexible cable to suitable for
connection to mono phase: H05 VV-F 3 G 4 mm2 or for 3 phase: H05 VV-F 5 G 1.5 mm2
Gas Connection and Security
1.
Before your appliance is connected to the gas supply, ensure that the gas category and pressure
specifications shown in the data plate corresponds with your gas supply. If necessary call authorized service
for adjusting to gas category.
2.
This appliance shall be installed in accordance with the regulations in force and only used in a well
ventilated space. Read the instructions before installing or using this appliance. In the interest of safety this
appliances must be installed and / or serviced by a competent person as stated in the gas safety regulations
current editions.