1.  Every user must read and un-

derstand this operating manual 
before operation.

2.  Observe general instructions 

for hazard prevention and 
safety instructions; e.g., wear 
protective clothing, eye protec-
tion and gloves.

3.  Carefully observe the operating 

manual and information from 
reagent manufacturers.

4.  Use the instrument only for 

pipetting liquids, with strict 
regard to the defined limita-
tions of use. Observe operating 
exclusions (s. page 21)! If in 
doubt, contact the manufac-
turer or supplier.

5.  Always use the instrument in 

such a way that neither the 
user nor any other person is 
endangered. Avoid splashes. 
Only use suitable vessels.

6.  Never use force on the instru-

ment!

7.  Use only original manufactur-

er’s accessories and spare parts. 
Do not attempt to make any 
technical alterations. Do not 
dismantle the instrument any 
further than is described in the 
operating manual!

8.  Always check the instrument 

for visible damage before use. 
If there is a sign of a poten-
tial malfunction, immediately 
stop pipetting. Consult the 
‘Troubleshooting’ section of 
this manual (see page 32), and 
contact the manufacturer if 
needed.

1. Safety Instructions

This instrument may sometimes be used with hazardous materials, 
operations and equipment. This Manual does not purport to address 
every safety issue which may arise during use. It is the responsibility of 
the user of this instrument to consult and establish appropriate safety 
and health practices and determine the applicability of regulatory limita-
tions prior to use.

20

Содержание maneus

Страница 1: ...e Auxiliar de pipeteado maneus Gebrauchsanleitung Operating Manual Mode d emploi Instrucciones de manejo VITLAB GmbH Linus Pauling Str 1 63762 Grossostheim Germany Telefon 49 6026 97799 0 Fax 49 6026...

Страница 2: ...the suction bellows 23 7 2 Attach the pipet 23 7 3 Fill the pipet 24 7 4 Adjust the meniscus 24 7 5 Discharge the pipet 25 7 6 After pipetting 25 8 Maintenance Cleaning 26 9 Replacing the membrane fil...

Страница 3: ...n the instru ment 7 Use only original manufactur er s accessories and spare parts Do not attempt to make any technical alterations Do not dismantle the instrument any further than is described in the...

Страница 4: ...00 mbar in order to prevent the liquid from boiling Density up to 2 4 g cm3 5 Storage conditions Store the instrument and accessories only in cleaned con dition in a cool and dry place Storage tempera...

Страница 5: ...1 3 4 5 6 2 3a 7 1 suction bellows 2 blow out button 3 valve unit 3a filteradapter 4 pipetting knob 5 membrane filter 6 adapter 7 adapter support 6 Components 22...

Страница 6: ...insert into the adapter 6 until it fits tightly Once the pipette has been attached always hold the instrument in a vertical position tip pointing downwards 7 2 Attaching the pipet 7 1 Compress the suc...

Страница 7: ...exchange the membrane filter 5 pages 27 29 Note The fill delivery rate is continuously variable with the upward downward pressure on the pipetting lever In the case of large pipettes 50 ml the vacuum...

Страница 8: ...moving start the necessary waiting time e g 15 sec Wipe the pipet tip along the wall of the vessel by sliding upwards a few millime ters 7 6 After pipetting To remove the pipet gently grasp near the...

Страница 9: ...is mainte nance free The exterior may be wiped with a damp cloth The complete instrument is au toclavable at 121 C 250 F 2 bar absolute 30 psi with a holding time of at least 15 minutes according to D...

Страница 10: ...t over a suitable vessel to allow all liquid to drain from the pipette 2 Grip the pipet as near the top as possible and carefully pull it out while turning 3 Unscrew the adapter support 7 4 Pull out t...

Страница 11: ...Not every membrane filter is suitable Use only genuine manufacturer s recom mended accessories Membrane filters of a pore size of 3 m are a standard equip ment of the instrument Up to 5 times the memb...

Страница 12: ...ntion for that the pipetting lever is loosely hanging Then place the pipetting lever scheduledly between the valves and close the housing s figure Does the pipetting lever not hang loosely but has twi...

Страница 13: ...pper part of the housing Carefully pull out the valve system and replace it 3 Reassemble the instrument in reverse order and carry out leak test Attention When cleaning and or exchanging the valve uni...

Страница 14: ...illed no liquid should drip unless the pipetting lever is de pressed If leaking occurs carefully pull out the pipet while turning and dismantle the instrument again If necessary replace mem brane filt...

Страница 15: ...rly positioned or valve unit 3 damaged carefully push pipet further into securing sleeve or insert membrane filter 5 or replace valve unit 3 Pipette not held properly adapter 6 damaged replace adapter...

Страница 16: ...s 1630500 complete with membrane filter Spare Parts Spare membrane filter 5 3 m sterile hydrophobic PTFE 10 per pack 1670650 Suction bellows 1 complet red 1670201 Adapter 6 silicone 1670301 Valve unit...

Страница 17: ...your supplier or the manufacturer for forms The forms can also be downloaded on www vitlab com Attention Only cleaned and decontaminated instru ments can be evaluated repaired 14 Repair service 15 War...

Отзывы: