System Setting
52
-
nORMAL : The disk is in a normal state.
-
CHECK : The disk has an error; check the disk and/or the connection cables.
If you leave the problem unresolved, it may affect the recording; it is recommended that you replace the disk
immediately.
-
ERROR : The disk has failed, and should be replaced immediately. Contact the retailer or service technician.
i
S.M.A.R.T CHECK InTERVAL : Specify the S.M.A.R.T check interval.
Click <CHECK nOw> to start checking.
3.
To apply the change, click <APPLy> in the bottom of the screen.
4.
when done, press the [EXIT] button on the remote control or click <CLOSE> in the lower screen. The confirmation
message appears and you will return to the previous menu.
Event Setup
Define various events, and specify the conditions to notify the user.
\
\
Alarm Out
Specify the alarm output conditions with the work schedule.
Alarm Out
1.
From <SySTEM SETUP> - <EVEnT>, select <ALARM OUT>.
2.
Use the [
▲▼◀▶
/EnTER] buttons on the remote control
or use the mouse to select <ALARM OUT> and
configure the related settings.
i
nAME : you can rename the alarm.
i
OPERATIOn : Set the alarm output mode.
-
n/O (normal Open) : It normally stays Open.
However, if an event occurs, it will switch to
Closed.
-
n/C (normal Closed) : It normally stays Closed.
However, if an event occurs, it will switch to
Open.
i
DURATIOn : Specify the duration of the alarm output.
-
TRAnSPAREnT : Keep the alarm out for as long as the event occurs.
-
UnTIL KEy : Keep the alarm out until a mouse or remote control button is pressed.
-
5 ~ 300 SEC : Keep the alarm out for a specified time.
i
TEST : Forcibly output the alarm testing purposes.
3.
To apply the change, click <APPLy> in the bottom of the screen.
4.
when done, press the [EXIT] button on the remote control or click <CLOSE> in the lower screen. The confirmation
message appears and you will return to the previous menu.