![Vitek VT-PTZ40WH Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vitek/vt-ptz40wh/vt-ptz40wh_user-manual_1036408019.webp)
VT-PTZ Series
18
INSTALLATION AND CONFIGURATION
Setting Protocols
A
Speed Dome
camera is capable of negotiating with multiple protocols if the
communication speed is matched (same baud rate i.e., 9600 bps). See Figure 13 for the
appropriate protocol switch settings.
Note
: Consult service personnel if a dome camera is installed with a device other than a
recommended Speed Dome Controller.
DIP S/W
FUNCTION
S5
Protocol
S5
D1
Protocol
D1
D2
D3
D4
D2
Off
Off
Off
Off
AUTO(No Parity)
D3
On
Off
Off
Off
AUTO(Even Parity)
D4
Off
On
Off
Off
PP
S6
D1
Extend ID
On
On
Off
Off
EZ
D2
Baud rate
Off
Off
On
Off
S2
D3
On
Off
On
Off
PD
D4
Off
On
On
Off
VC
On
On
On
Off
SN
Off
Off
Off
On
DC
Off
On
Off
On
PS
On
Off
On
On
VL
Off
On
On
On
DI
On
On
On
On
Factory Reset
S6
Baud rate
D2
D3
D4
Off
Off
Off
2400 bps
Off
Off
On
4800 bps
Off
On
Off
9600 bps
Off
On
On
19200 bps
On
Off
Off
38400 bps
Figure 13 - Protocol Selection Tables