background image

19

Appendix: WDR Mighty Dome

 

 

                                                                                                         

 

6)  ZONE  ADJ.  Menu

 

 
 

Adjusts  the  size  and  the  location  of  the  metering  zone  for  the  dynamic  range  control. 
Dynamic  range  control  is  very  sensitive  to  the  size  and  the  location  of  the  zone. 
The  default  window  size  is  SAFE  AREA. 

 

To  enter  ZONE  ADJ  menu,  press 

  button  at  <ZONE  ADJ  .  .  .>  of  WDR  CUSTOM  menu. 

 
 

 

 
 
 
 
 
 
 
 
 
 
 

In  ZONE  ADJ  menu,  'NEXT:MENU-'  stands  for  'press 

  button  short  for  next  menu'   

and  'RETURN:MENU---'  means  'press 

  button  longer  than  2  sec  for  return  or  exit'. 

,

,

,

  buttons  are  used  for  move,  enlarge  or  reduce  the  zone. 

 

White  zone  boundary

  moves  the  zone  to  locate  it  at  the  optimal  position. 

Green  zone  boundary

  enlarges  the  zone. 

Red  zone  boundary

  reduces  the  zone. 

 
 
 

7)  BLC  ZONE  SELECT  menu 

 

To  enter  BLC  ZONE  SELECT  menu,  press 

  button  at  <BLC  .  .  .            >  of  EXPOSURE  menu. 

 
 
 

 

 
 
 
 

Metering  of  the  back  lit  compensation  control  is  weighted  to  the  selected  window  from  CTR 

SPOT(1/9  of   

entire  screen),  UPPER  1/3,  MIDDLE  1/3  and  LOWER  1/3. 

 

Содержание Mighty DomeColor Dome Camera Series

Страница 1: ...Day Night function available Flush or Surface Mount UTP interfaceand Heater Blower Options Available Dual Voltage 12VDC 24VAC Infinity Ball Mount for Any Viewing Angle Indoor and Vandal Proof IP 68 Rated Models Available Lens options include 2 9 10mm 9 22mm or 18 50mm Available in ivory or black ...

Страница 2: ...the dome cover to the flush housing Type Phillips head M4x10 Length 10mm Diameter 4mm Qty 4 Self Tapping Screws For attaching the surface mount housing or the the flush mount base to a solid surface Type Phillips St4x30 Length 30mm Diameter 4mm Qty 4 Self Tapping Screws Indoor Version Only For attaching the dome cover to the flush housing Type Phillips St4x12 Length 12mm Diameter 4mm Qty 4 Dowels ...

Страница 3: ...N True Day Night Vandal Proof Color Dome Camera w 2 9 10mm or 9 22mm Varifocal Lens 480TVL VTD MVX2910 MVX922 MVX1850 Vandal Proof Color Dome Camera w 2 9 10mm 9 22mm or 18 50mm Varifocal Lens 550TVL VTD MVX2910DN MVX922DN MVX1850DN True Day Night Vandal Proof Color Dome Camera w 2 9 10mm 9 22mm or 18 50mm Varifocal Lens 550TVL WDR Mighty Dome Configurations VTD MX922 WDR MX2910 WDR Indoor Color D...

Страница 4: ...Camera Holder and 2nd Video output 5 Ball with the Camera Assembly 6 Safety Wire 7 Bubble 8 Dome Cover Ring 9 Flush Mount Base 10 Surface Mount Plate 11 Assembly Screws Torx M4x9 Vandalproof 12 Assembly Screws Phillips ST4x12 Indoor Phillips M4x10 Vandalproof IR 13 Mounting Screws Phillips ST4x30 ...

Страница 5: ...ome cover 2 Flush Mount Installation Using four St4x30 screws attach the flush mount base to a sturdy surface 3 Surface Mount Installation Drill pilot holes at the mounting location using the provided mounting template Using four St4x30 screws mount the surface mount housing to a sturdy surface Using four ST4x12 Indoor screws or M4x10 Vandal proof screws attach the flush mount base to the surface ...

Страница 6: ...ION BOX INSTALLATION Mighty Domes can easily be flush or surface mounted to an electrical junction box J Box using the pre drilled mounting holes on either the surface mount housing or the the flush mount base ...

Страница 7: ...om its base 1 Remove the ball gimbal from its socket and hold the base firmly with one hand 2 Gently squeeze Point A and B and pull away from the base until the gimbal is removed from the base 3 Replace the Gimbal cover by aligning the cover to the base and pressing down until it snaps back onto the base ...

Страница 8: ...7 CONNECTIONS Power connection 12VDC and 24VAC dual input All Mighty Dome cameras come standard with a secondary video output The secondary video cable VT MD 2VOC is included in the box ...

Страница 9: ... base 2 Loosen Zoom Focus screws and make necessary adjustments as shown Field of view Telephoto T to Wide W Focus Near N to infinity 3 DC Level Adjust left or right if the picture is too dark 4 Dip Switches See Page 9 5 Reattach the gimbal cover to the gimbal base 8 ...

Страница 10: ...Control BLC Auto Gain Control AGC Flickerless Sharpness Day Night IR Mode IR Model Only ALC Off Normal Off Normal Day Off ELC On Turbo On Sharp Auto On 1 2 3 4 5 6 7 8 Function OFF ON N A ELC ALC Back Light Control BLC Auto Gain Control AGC ALC Off Normal ELC On Turbo 1 2 3 4 Indoor Vandal Proof Mighty domes non day night ...

Страница 11: ...black 10 3 AXIS GIMBAL ADJUSTMENT The Gimbal mechanism yields maximum rotation and placement as shown below ...

Страница 12: ...11 DIMENSIONS ...

Страница 13: ...e Pixels Electronic Shutter White Balance Operating Temperature Operating Humidity Power Consumption Power Requirement Dimensions H x Dia 1 3 Super HAD CCD Internal 2 1 Interlace 2 9 10mm 9 22mm or 18 50mm 480 TV Lines 550 TV Lines 0 2Lux F1 2 40IRE More than 52dB AGC OFF at 50IRE 1 0Vp p composite 75 Ohms 768 H x 494 V 1 60 1 100 000 2000 8000 K Automatic Tracking 14F 122F 10C 50C Within 85 RH 3 ...

Страница 14: ...uirement Dimensions H x Dia 1 3 Super HAD CCD 1 3 True Day Night Super HAD CCD Internal 2 1 Interlace 2 9 10mm 9 22mm or 18 50mm 480 TV Lines 550 TV Lines 480 TV Lines 550 TV Lines Day Night 0 02Lux F1 2 40IRE Standard 0 2Lux F1 2 40IRE More than 50dB AGC OFF at 50IRE 1 0Vp p composite 75 Ohms 768 H x 494 V 1 60 1 100 000 2000 8000 K Automatic Tracking IP68 14F 122F 10C 50C Within 85 RH 3 Watts 12...

Страница 15: ...n Power Requirement Dimensions H x Dia 1 3 Super HAD CCD Internal 2 1 Interlace 2 9 10mm 9 22mm or 18 50mm 480 TV Lines 550 TV Lines Day Night 0 02Lux F1 2 40IRE Standard 0 2Lux F1 2 40IRE More than 50dB AGC OFF at 50IRE 1 0Vp p composite 75 Ohms 768 H x 494 V 1 60 1 100 000 2000 8000 K Automatic Tracking 35 LED s with up to 90 Range IP68 14F 122F 10C 50C Within 85 RH 3 Watts IR LEDs Off 6 Watts I...

Страница 16: ...500 series 0 45 Internal 2 1 Interlace 2 9 10mm 9 22mm 550 TV Lines 0 0002Lux with DSS ICR Modes ON F1 2 40IRE More than 50dB AGC OFF at 50IRE 1 0Vp p composite 75 Ohms 768 H 494 V 1 60 1 30 720sec fully automatic global electronic shutter 2000 11000ºK Automatic tracking 4 presets Low Middle High Custom DC drive iris control Level control is fixed internally 2X 4X 8X 16X 32X ESS 4 areas CTR SPOT U...

Страница 17: ...or rolling of the NTSC system by line lock synchronization AC24V version Offers on screen menu With ICR mechanism Enhances sensitivity about 10x at night time Can accept infrared light With 24VAC 12VDC dual power design Offers flexibility in installation Ensures reliability Main features are 1 3 RGB Color DPS SENSOR Pixim Orca D1500series All adjustments by OSD menu Resolution of 540 Horizontal Li...

Страница 18: ...ESET Descriptions NORMAL Produces an image that has average contrast and suitable for normal indoor or low contrast outdoor scenes INDOOR Provides better leveling of image for in the darker areas of the scene Suitable for indoor scenes that have higher contrast lighting OUTDOOR Optimized for outdoor sunlit applications and provides better leveling for the brighter areas Suitable for outdoor scenes...

Страница 19: ... dynamic range control for each PRESET WDR HIGH Increases the dynamic range control Some highlight area may be washed out CUSTOM Provides more flexible compensation other than WDR MID WDR LOW WDR HIGH BLC Compensates the brightness of main object against the bright back light A zone out of CTR SPOT UPPER1 3 MIDDLE1 3 LOWER1 3 can be set Dynamic range control is inoperative if EXPOSURE is set to BL...

Страница 20: ... for press button short for next menu and RETURN MENU means press button longer than 2 sec for return or exit buttons are used for move enlarge or reduce the zone White zone boundary moves the zone to locate it at the optimal position Green zone boundary enlarges the zone Red zone boundary reduces the zone 7 BLC ZONE SELECT menu To enter BLC ZONE SELECT menu press button at BLC of EXPOSURE menu Me...

Страница 21: ...nd verified at the final step of the installation because they may be affected by the settings such as the size or location of the metering window Block the lens for a few seconds for NIGHT mode and release it to be returned to DAY mode If camera stay at NIGHT mode more than 10sec increase EXIT THRES and repeat the fore mentioned steps If the scene is too dim it may not be returned to DAY EXIT DEL...

Страница 22: ...e longest shutter is limited to 4X 32X of 1 60 NTSC 1 50 PAL sec when the scene illumination becomes dim The higher integration increases the sensitivity but decreases the video refresh rate WHITE BALANCE Descriptions ATW NORMAL White balance is compensated automatically in range of 2800K 7500K ATW Desat White balance is compensated automatically in range of 2000K 11000K In the range of 2000 2800K...

Страница 23: ...ROL Descriptions BRIGHTNESS BRIGHTNESS level is a kind of video output gain and is different from the iris level control It can be set to MID LOW MIDDLE MID HIGH HIGH and LOW If it is set too high the dynamic range is decreased DNR ON reduces the dynamic noise but effects video SHARPNESS SHARPNESS MIDDLE HIGH MAX LOW FLIP OFF provides the normal video H FLIP V FLIP provides the horizontally vertic...

Страница 24: ...ther presets when the scene is very bright 15 VIDEO SYNC menu VIDEO SYNC Descriptions INT Synchronization is INTERNAL regardless of the power source INT2 Synchronization is INTERNAL but sync frequency is modified to simulate line lock It is not actually synchronized to the line frequency AUTO Synchronization mode is decided automatically by the power source Line lock for AC24V and Internal for DC1...

Страница 25: ... Exits menu with discarding any changes RESTORE FACTORY SETTINGS Restores and saves all parameters of factory settings Camera resets and restarts automatically LANGUAGE English is available only Language does NOT change by RESTORE FACTORY SETTINGS VIDEO STANDARD NTSC and PAL can be switched VIDEO STANDARD does NOT change by RESTORE FACTORY SETTINGS ...

Страница 26: ...25 Appendix WDR Mighty Dome 17 Setup Menu Tree ...

Страница 27: ...u with discarding any changes RESTORE FACTORY SETTINGS Restores and saves all parameters of factory settings Camera resets and restarts automatically LANGUAGE English is available only Language does NOT change by RESTORE FACTORY SETTINGS VIDEO STANDARD NTSC and PAL can be switched VIDEO STANDARD does NOT change by RESTORE FACTORY SETTINGS ...

Страница 28: ...om the date of purchase The product must have been used only for its intended purpose and not been subjected to damage by misuse willful or accidental damage caused by excessive voltage or lightning The product must not have been tampered with in any way then the guarantee will be considered null and void This guarantee does not affect your statutory rights Contact VITEK directly for all servicing...