background image

11 

Warning 

The product is intended to 

transport by car 

Catalog number 

The product is intended to the 

transport by plane 

Serial number 

 

The  product  is  compliant  with  standards  on  electrical  and  electronic  equipment.  It 

should  not  be  disposed  with  other  waste  from  households.  The  user  is  responsible  for  providing  the 
equipment at the end of its service life to the appropriate collection points, under penalty of sanctions 
provided  by  the  law  applicable  in  the  matter  of  waste  disposal.  For  further  information  on  the 
collection schemes available can be obtained from the local waste disposal center. 

Contact deta

ils

mdh 

S

p. z o.o.

ul. Maratońska 104, 94-007,

 Łód

ź

Polska

tel. +48 42 674 83 84 
fax. +48 42 636 52 21 
www.mdh.pl www.viteacare.com 

Medical device

Содержание Tube Light

Страница 1: ...1 Use r manual Tube Light Anti bedsore alternating pressure mattress of tubular structure VCM502F Edition EJ 01 2022...

Страница 2: ...Description of product 3 3 Use 4 4 Contrandications 5 5 Operation 5 6 Safety of use 7 7 Everyday use and maintenance 8 8 Technical parametres 11 9 Symbols 11 10 Contact details 12 PLEASE READ CAREFUL...

Страница 3: ...with a cover Made of PCV which enable fast and easy cleaning Smooth manual pressure regulation adjusted individually to patient s weight 2 Description of product Illustration 1 1 The air chamber 2 Ma...

Страница 4: ...diversion The air insulation provides an optimal temperature and comfort of use All of the above mentioned factors play crucial role for bedsore prophylaxis and treatment The variable pressure mattres...

Страница 5: ...ly takes 20 30 minutes After inflating the mattress you should choose the pressure according to the doctor s recommendation Then place the cover included in the pockege of the antibedsore mattress usi...

Страница 6: ...tion if the pump is used in the presence of children or people witch disabilities m The pump can be used according to its purpose only n Do not use it with other unauthorized devices o Never use the p...

Страница 7: ...of body suport points Patient s body rests on the same invariable height regardless of the phase of pump functioning PHASES OF PUMP FUNCTIONING 1 phase Inflating all the cells 2 phase Deflating the fi...

Страница 8: ...p REPLACING THE AIR CHAMBER In a situation when one air chamber is damaged replace it with a spare attached in the box To do this turn off the pump unplug the cable from the wall outlet Deflate the ma...

Страница 9: ...the reparation kit Please check if the pump works correctly if you can hear some strange sounds like hissing etc you should submit it to the reparation CARE AND MAINTENANCE Disconnect the pump from e...

Страница 10: ...rial Nylon PVC Fuse 1 A Description of the environment in which the product will be used temperature of storage and use from 10 C to 40 C The humidity for the storage and use from 10 to 95 Pressure ra...

Страница 11: ...The user is responsible for providing the equipment at the end of its service life to the appropriate collection points under penalty of sanctions provided by the law applicable in the matter of wast...