VitBest M-0404SE Скачать руководство пользователя страница 2

 

 
 
 
VitBest M-0404SE User Manual

                              

 

 

2

Double click the PC 

tool software

.It will automatically 

connect to the matrix via COM port. 
3

If the connection is 

successful

, the corresponding display 

will be blue 

4) If the connection is

 failed

, please 

check 

the causes and 

retry

 again according to the software’s hint.Usually,the 

causes may be as follows: No COM port connected to the 
computer,the COM port is used by other programmes ,the 
matrix is not working well,and so on. 

6) The C

omboBox

 on the right of Port shows the COM ports 

that connected to the computer. If there’s no COM port 
connected,it will shows COM0,COM1

COM9. 

7) The 

button

 on the right of Status indicates the current 

status of connection.You can switch the connection status 
by pressing this button. 

 

 

 
 
 
 
 
 
 
 
 
 
 
Instruction of control operation of matrix: 

 
1) Click the 

rectangle

 which is on the right of output port and 

on the bottom of the input port can switch output port’s input 
source.And the rectangle’s color will change to 

blue

 if the 

Содержание M-0404SE

Страница 1: ...Act Shows if the corresponding input signal is active Link Shows if the sink device is connected SEL EDID EDID option Auto Auto parse EDID Manual User can configure the EDID with PC Tool 2D EDID opti...

Страница 2: ...is used by other programmes the matrix is not working well and so on 6 The ComboBox on the right of Port shows the COM ports that connected to the computer If there s no COM port connected it will sho...

Страница 3: ...r close the IDID control window by clicking this button The instruction of operation of EDID control is as below EDID Read Port Output Select a output port which will do EDID operation EDID Write Port...

Страница 4: ...k Jitter 0 15 Tbit 1080p 60 RiseTime 0 3Tbit 20 80 RiseTime 0 3Tbit 20 80 Transmission Delay 5ns Amplitude T M D S 0 4Vpp Differential impedance 100 15ohm RS232 control Baud rate and protocol Baud rat...

Страница 5: ...r flash point on the screen please check if the connection is reliable whether the source is a standby or replace the HDMI cable 2 When user can t control matrix with PC please check if com port No is...

Страница 6: ...nd body CMD_LENGTH bytes Check sum 1 byte Command tail 2 byte CMD_HEAD CMD_INDEX CMD_LENGHT CMD_BODY CMD_CHECKSUM CMD_TAIL 0x7b 0x7b 0x7d 0x7d Note Check sum is the low 8bits of the sum of CMD_HEAD CM...

Страница 7: ...7 of the Outputs byte represent HDMI output port 1 8 3 The input byte represent the input port index 0 7 represent HDMI input port 1 8 Example Switch the input 2 to output 1 Switch the input 4 to all...

Страница 8: ...xample Save the current routing configuration to index 1 Save the current routing configuration to index 8 Command 7B 7B 02 01 00 F3 7D 7D Command 7B 7B 02 01 07 FA 7D 7D 7b 7b Command head 02 Command...

Страница 9: ...g configuration index 8 Command 7B 7B 03 01 00 F4 7D 7D Command 7B 7B 03 01 07 FB 7D 7D 7b 7b Command head 03 Command index 01 Command length 00 Command body 00 Means 1 routing configuration index 1 0...

Страница 10: ...trix The current routing information is 1 1 2 2 3 3 4 4 HDMI 4x4 Matrix The current routing information is 1 1 1 2 1 3 1 4 Command 7B 7B 11 04 00 01 02 03 0B 7D 7D Command 7B 7B 11 04 00 00 00 00 05 7...

Страница 11: ...have picture display well otherwise will failed Example Read the EDID data from the device that connected to HDMI output 1 Receive With respect to the HDMI device Send With respect to the HDMI device...

Страница 12: ...7D 7D 7B 7B 15 12 00 B0 20 B8 28 55 40 C4 8E 21 00 00 1E 01 1D 80 D0 72 CD 7D 7D 7B 7B 15 02 00 C0 07 7D 7D 7B 7B 15 12 00 C0 1C 16 20 10 2C 25 80 C4 8E 21 00 00 9E 8C 0A D0 81 7D 7D 7B 7B 15 02 00 D...

Страница 13: ...r device received this command will write the 16 bytes EDID data from the EDID data index that set by the command If write successes will return the same command as that the device received Please mak...

Страница 14: ...1 00 00 6D 03 0C 00 10 13 7D 7D 7B 7B 18 12 00 90 26 09 7F 03 11 7F 18 83 01 00 00 6D 03 0C 00 10 13 7D 7D 7B 7B 18 12 00 A0 00 B8 3C 2F 80 60 01 02 03 01 1D 00 BC 52 D0 1E DD 7D 7D 7B 7B 18 12 00 A0...

Страница 15: ...to obtains IP address 7B 7B 13 01 01 05 7D 7D Command head 2byte Comman d Index 1byte Command length 1byte Command body CMD_LENGTH byte Check su m 1byte Command tail 2byte 0x13 0x01 0x01 0x05 0x7b 0x7...

Страница 16: ...VitBest M 0404SE User Manual 05 Command length 00 Manual C0 A8 01 01 The Hex of 192 168 1 1 72 check sum 7d 7d Command tail...