Vitamix Vitamix XL Скачать руководство пользователя страница 10

Motor Base/Control Panel

1. 

Unplug the power cord.

2.  Gently wash the outside surface with a damp soft cotton cloth moistened  

with a mild solution of warm water and nonabrasive detergent or nonabrasive  

liquid spray cleaner. 

Never immerse motor base in water or other liquid.

3.  Thoroughly clean switches so that they work freely. They may become sticky from 

use. Unplug the machine and use a wet cloth, moistened with water* and a mild 

detergent, to clean around the edges of the switch paddles until they function freely. 

Work the switches back and forth a few times to loosen any dried residue under 

switch. Leaving switches sticky will damage or burn out the switches. Clean carefully, 

using caution not to allow water or other liquids to infiltrate the switch. 

4.  Dry with a soft cotton cloth.

Container and Lid

Separate the lid and plug. Wash in warm soapy water. Rinse clean under  

running water and dry. Reassemble before use. (See page 13.)
1. 

To Clean:

 Fill container 1⁄4 full with warm (110˚F / 43˚C) water and add 

a couple drops of liquid dishwashing detergent.** Return container to motor  

base and firmly position the two-piece lid. Run machine for 30 seconds.  

Empty container. Repeat this step.

2. 

To Rinse:

 Fill container 3⁄4 full with warm (110˚F / 43˚C) water, do not 

add soap. Return container to motor base and firmly position the  

two-piece lid. Run machine for 30 seconds. Empty container.

3. 

If any solid residue remains, remove the blade assembly (see page 15)  

and wash all container parts in warm soapy water. Rinse and drain.  

Reassemble before next step. Do not soak the blade assembly.

4. 

To Sanitize: 

If all solid residue is gone after step 2 or after completion of 

step 3, fill container 3⁄4 full with a sanitizing solution mix.*** Return container  

to motor base and firmly position the two-piece lid. Run machine on a high  

speed for 30 seconds. Turn machine off and allow mixture to stand in the  

container for an additional 1 1⁄2 minutes. Pour out sanitizing solution.  

Return container to motor base and run machine empty for an additional  

5 seconds. Do not rinse after sanitizing. Allow container to air dry.

CARING FOR YOUR MACHINE

18

Safety Interlock Lid (select machines)

Clean with a damp cloth while in place on the machine or for a more thorough 
cleaning lift the safety lid out of the slots on the side of the machine and wash with 
mild dish detergent. Reassemble before use. Do not wash in dishwasher.

19

IMPORTANT NOTES!

*

   Be sure to wring excess water out of cloth or sponge when 

cleaning around the controls or any electrical part.

**

   To prolong container life, Vitamix® recommends using soaps with a 

low Ph balance, such as a liquid dishwashing detergent (Ivory Liquid®). 

***

  Recommended sanitizing solution: 1.5 tsp. / 7,4 ml institutional or 

household bleach in 2 qt. / 2,0 L water.

Cover:

 Do not wash cover door, handle or back cover in dishwasher. It is

recommended that the handle not be disassembled during cleaning. However, if
you choose to disassemble the handle from the cover, make sure to not
over-tighten it when reattaching it to the cover. Doing so will cause damage.

Container:

 Do not let mixtures, liquids or food products dry in the container.

Rinse after use. Dry product may lock around the blade and weaken/tear the
bearings seal when restarted. Do not place containers in the freezer.
Extremely low temperature combined with hot ingredients and/or the
immediate rapid action of the blade may crack the container. Due to the nature
of polycarbonates used in the Advance containers and the sound cover assembly,
microwaving and automatic dishwashing are not recommended.

WARNINGS!

Содержание Vitamix XL

Страница 1: ...Vitamix XL Use and Care Manual Read and save these instructions Large Capacity Blender ALL MODELS ENGLISH I ESPAÑOL I FRANÇAIS ...

Страница 2: ...el All Models Maintenance Tips Blending Tips Control Panel 10 Programming 12 Programming Custom Chip Resetting Pre Set Buttons Machine Assembly 13 Lid Assembly Safety Interlock Blade Assembly Accelerator Tool Caring for your Machine 17 Troubleshooting 20 Warranty 22 Parts List 24 Product Specifications 26 ...

Страница 3: ...e container and is substantially less with thick mixtures 14 Container should not be more than 2 3 full when the accelerator tool is left in place while blending Do not exceed 30 seconds of continuous blending while accelerator tool is in place 15 CAUTION Cooling problems resulting in thermal shut off and eventual motor damage may result if machine is operated in sound chambers other than those ap...

Страница 4: ...art Stop switch To prevent possible splashing lightly rest your hand on the lid while turning the machine on except when processing hot liquids or mixtures Until you become accustomed to the speed watch your mixture carefully to avoid over blending If during blending the mixture seems too thick remove the lid plug and slowly add liquid through the lid opening while processing Vitamix XL Variable S...

Страница 5: ...achine run without the container This will circulate air around the motor housing cooling the motor 9 IMPORTANT NOTES The automatic overload protection shuts the motor off to protect the motor The motor may stop working if it is overloaded or overheated If the motor shuts off it could be due to Recipe being too thick Recipe having too many ingredients in it Recipe was being processed too long at t...

Страница 6: ... Stop Switch Program Dial Pulse Switch Vitamix XL Programmable OFF ON 16 A FIGURE A OFF ON 16 A FIGURE B IMPORTANT NOTES Vitamix machines come with several different control options Please be sure you are following the instructions for your model Vitamix XL Programmable On Off Power Switch Located on the side of the machine Figure A the On Off switch controls the power to the machine While plugged...

Страница 7: ...l Lid 64 oz 2 0 L Advance Container To secure lid place on top of container and gently press down until lid snaps into place making sure the latches are secured around the top of the container rim To remove a fully latched lid lift one of the two tabs and pull upward and off Twist the center lid plug to fasten or remove The lid plug can be removed when using the accelerator tool or adding ingredie...

Страница 8: ...elow to remove or replace Drive Spline Inserts into drive socket on the motor base to turn the blade Note Removing and replacing your container while the coupling is still rotating will strip the drive spline teeth This part is NOT removable Retainer Nut Must be snug Order the available Retainer Nut Wrench for best results Refer to the information below to remove or replace Blade Assembly Removal ...

Страница 9: ...S Cleaning Products Do not use abrasive cleaning agents or concentrated bleach when cleaning Do not use any cleaners containing quanitary sanitizers on polycarbonate components i e Advance containers covers Do not use any of the following cleaning products automatic dishwashing detergents oven cleaners steel wool or other abrasive pads Splash Disk Splash Disk WARNINGS Do not force the accelerator ...

Страница 10: ...ll with a sanitizing solution mix Return container to motor base and firmly position the two piece lid Run machine on a high speed for 30 seconds Turn machine off and allow mixture to stand in the container for an additional 1 1 2 minutes Pour out sanitizing solution Return container to motor base and run machine empty for an additional 5 seconds Do not rinse after sanitizing Allow container to ai...

Страница 11: ...rned on but there is no power Machine did not work right out of the box Setting selected starts the wrong program Programmable model only Possible Actions a Try plugging the machine into a new outlet b Reset the machine to its original factory settings See page 12 Programmable model only c Machine may stop working if it is overloaded on low speed To cool the motor reset by turning power off for up...

Страница 12: ...nd enclosure or exposure to extreme conditions and is only valid if the Equipment is used in accordance with the accompanying instruction booklet which may also be accessed at www vitamix com foodservice If applicable improper installation or ventilation in the case of the in counter model of the Equipment or placing the Equipment in a sound enclosure not manufactured by Vita Mix will void this wa...

Страница 13: ...lade agitator assembly for Advance container 15942 Retainer nut for Advance container for Vitamix XL only 15902 Drive socket 15895 Vitamix XL centering pad 755 Lid plug for 1 5 gal 5 6 L container and Advance container 760 Accelerator tool 102035 Accelerator tool for machines with the safety interlock only PARTS LIST IMPORTANT NOTES Outside the U S A and Canada your machine may come with a differe...

Отзывы: