3. Scope of supply / system solutions

 

 

4. Technical data / Information

 

5. Additional information

4.4 Information 

Basic information on the instrument design

• 

The instrument is designed according to state-of-the-art technology and recognized safety standards.

• 

However, inappropriate use may endanger the health and safety of the user or third parties and lead to a risk of damage to 
the instrument and other material property.

Unauthorized modes of operation

• 

Do not operate the control unit with sharp-edged or hot objects. This causes damage to the touch screen.

• 

The operation of the instrument with power sources, products, etc., which are subject to hazardous materials regulations or 
could have any negative impact on the health of the operating personnel when using equipment modified by the user, are not 
permitted.

• 

The unit may not be used without the sintering stand. The sintering stand must always be inserted in its designated recess 
on the bottom of the sintering unit. The unit may not be used with a flammable narcotic agent with air or nitrous oxide.

• 

The device is equipped with a fan. The fan is temperature-controlled. Activation, deactivation and speed of the fan are 
controlled automatically. The fan prevents excessive heating of the unit and contributes to the overall operational safety. The 
openings in the top cover of the sintering chamber, as well as the opening in the back cover, must not be covered or closed. 
The unit may not be used without the fan.

Authorized modes of operation

• 

The insulation of the sintering chamber contains ceramic mineral fibers (Index No. 650-017-00-08), which are classified as a 
Cat. 2 carcinogen (Annex VI, EC 1272/2008). When working with the sintering chamber or exchanging the heating element, 
fiber dust may be discharged.

• 

Dust may be harmful if inhaled and cause irritation to the skin, eyes and respiratory system. When replacing parts of the 
sintering chamber, please observe the following instructions:

 Wear long-sleeved protective clothing.

 Wear safety goggles, as well as protective gloves.

 Use a dust vacuum system or wear an FFP-2 respirator.

 Once work has been completed, rinse the dust from unprotected skin using cold water.

 Wash workwear separately from everyday clothing.

• 

The operation of the device is only permitted if this operating manual has been completely read and understood and the 
procedures described in it have been observed. Any other or additional use, e.g., processing of products other than those 
intended is considered misuse, as is the handling of hazardous materials or substances that are dangerous to personal 
health.

• 

Repairs and servicing of any kind may only be carried out by specially trained personnel.

Please note: 

• 

The manufacturer/supplier will not be liable for any damage resulting from such unauthorized use. The risk of such use is borne 
exclusively by the user.

Содержание ZYRCOMAT 6100 MS

Страница 1: ...COMAT 6100 MS VITA perfect match Operating manual Date of issue 02 19 VITA Farbkommunikation VITA Farbkommunikation VITA shade control VITA shade reproduction VITA shade communication VITA shade deter...

Страница 2: ...d safe operation To be able to use the sintering furnace safely and effectively please read these operating instructions completely before use This operating manual must always be kept close to the de...

Страница 3: ...Sintering chamber insulation 16 5 Additional information 5 1 VITA warranty and consumer protection 17 5 2 Update messenger 17 5 3 Spare parts 17 5 4 Patents and trademarks 17 5 5 Hotline and support...

Страница 4: ...4...

Страница 5: ...ntrolling two or more VITA furnaces using the VITA vPad excellence you will need a VITA SWITCHBOX with connecting cable The VITA SWITCHBOX is an adapter for connecting two to four firing devices to th...

Страница 6: ...nd two part Lift plate Connection for VITA vPad comfort VITA vPad excellence VITA SWITCHBOX Cooling table Mains power supply connection Main switch Status display Note What High quality sintering furn...

Страница 7: ...sintering dish is set at a maximum of 40 units Whenever you open the furnace always ensure that all doors and windows are closed so that the sintering dish is not exposed to a cold air draft 1 2 Acces...

Страница 8: ...8...

Страница 9: ...am for the first time please set the status display insert the metal ring turn it clockwise and let it engage Then insert the two part sintering base Please note Please start the program only if the s...

Страница 10: ...inimum distance of 50 cm Avoid direct sunlight on the device Do not place flammable objects near the device Do not place the control unit directly in the area of heat radiation of the sintering chambe...

Страница 11: ...ply system solutions 4 Technical data Information Article Scope of supply VITA ZYRCOMAT 6100 MS 1x Sintering stand 2x Sintering dish 1x Tongs 1x 150g ZrO2 spheres 1x Status display light bar 1x Connec...

Страница 12: ...n the VITA Linearguide 3D MASTER for example Various geometries translucency and chroma levels of VITA YZ blanks are available for CAD CAM fabrication For manual coloring of the milling results use th...

Страница 13: ...t always disconnect it from the mains current by unplugging the power plug Residual voltage After the back plate has been removed a residual voltage of up to 400 V may still be present in components i...

Страница 14: ...top cover of the sintering chamber as well as the opening in the back cover must not be covered or closed The unit may not be used without the fan Authorized modes of operation The insulation of the s...

Страница 15: ...tes An error message is displayed once power is restored Obstruction sensor The vertical movement of the lift plate is controlled by computer Any trapped objects are detected and the drive is switched...

Страница 16: ...he gray oxide layer of the heating elements is discovered during this visual inspection it is imperative to carry out a cleaning firing The cleaning firing builds up the oxide layer and gives the surf...

Страница 17: ...es e mailed to you an option to register is provided at www vita zahnfabrik com update messenger 5 3 Spare parts Spare parts must comply with the technical requirements specified by the manufacturer T...

Страница 18: ...18 NOTES...

Страница 19: ...VITA product solutions you can contact our technical specialists Mr Ralf Mehlin or Mr Daniel Schneider Phone 49 0 7761 56 22 22 Fax 49 0 7761 56 24 46 8 00 a m to 5 00 p m CET Email info vita zahnfab...

Страница 20: ...e use with regard to its suitability for the intended area of applications We cannot accept any liability if the product is used in conjunction with materials and equipment from other manufacturers th...

Отзывы: