background image

 

TO CHANGE TO 
INDIVIDUAL DAYS 
OF THE WEEK: 
7 – Saturday 
6 – Friday 
5 – Thursday 
4 – Wednesday 
3 – Tuesday 
2 – Monday 

1 – Sunday 

continues on next page

USE ARROWS TO 

CHANGE TEMPERATURE 

3s 

USE ARROWS TO 

CHANGE ºF to ºC 

USE ARROWS 

TO CHANGE 

*

*

 If the display shows AH or ECO 

instead of hd=A, the swim controller is 

programmed incorrectly. Call a service 

technician for instruction on 

reprogramming. 

 

SWIM PROGRAMMING INSTRUCTIONS 

REFER TO PROGRAMMING INSTRUCTIONS ON PAGE 22 FOR QUICK PROGRAMMING STEPS 

 

 

A. PROGRAMMING MENU  .....................................................  

Note: All programming functions are shown sequentially. To access any 
specific programming step, you have to enter programming as explained 
here. 

Press and hold 

 

for three (3) seconds until 

“dISC”

  is  on  the  screen  to 

enter the programming menu.  

To exit programming mode at any point in the sequence, press any button 
other than 

 or 

, or wait for 10 seconds (without pressing any 

button).  

B.  HEAT DAYS & TEMPERATURE ............................................  

Your spa is pre-programmed from factory to heat “All” days, 

“hd=A”

. It has 

however the ability to be programmed for different temperatures on different 
days of the week. To do so, follow these steps:  

Example: Let's assume that you don’t normally use the spa between Mondays 
and Thursdays and you want to save on your electric bill by reducing the 
spa’s energy consumption. 

1.

 

While the display shows “hd=A”, press 

. The 

display will show the heat day. Press 

 

again until 

the desired heat day is selected  ..............................  

2.

 

Press 

 to display temperature for the day 

selected. Press and hold 

 

to lower temperature 

to, for instance, to 80ºF (27ºC). Press 

 to increase the temperature. 

3.

 

To check or adjust the temperature on another day, press 

 

to cycle through the 

program until the display shows 

“hd=A”

 again. Then repeat steps 1 through 3 to do 

the same for Wednesday (hd=4), Tuesday (hd=3) and Monday (hd=2). 

NOTE

: If you programmed different temperatures at different days, DO NOT alter the 

temperature setting after the display shows 

“hd=A”

. If you do so, “All” days will revert 

to the newly set temperature. 

C.  TEMPERATURE – ºF or ºC..................................................  

Your spa is pre-programmed from factory to display temperature in degrees 
Fahrenheit (ºF). Use the arrow keys to change between degrees Celcius (ºC) 
and degrees Fahrenheit (ºF). 

D. FILTRATION (CIRCULATION) CYCLE ................................  

Your spa is pre-programmed from factory to run the filtration cycle for 12 
hours a day. You may change this setting to 6 hours or 24 hours a day. It is 
recommended that filtration hours be set to the minimum necessary to 
maintain water quality. 

Notes:  During filtration, the water temperature may slightly rise, therefore to 

prevent overheating during the warmer months of the year, do not 
program filtration for more than 4 hours a day. 
Keeping your set temperature a few degrees below your desired 
temperature will aid in controlling water temperature

a.

 

hd=7 Saturday 

b.

 

hd=6 Friday 

c.

 

hd=5 Thursday 

d.

 

hd=4 Wednesday 

e.

 

hd=3 Tuesday 

f.

 

hd=2 Monday 

g.

 

hd=1 Sunday 

PAGE 13

Содержание xStream

Страница 1: ...mi Florida 33054 www dmindustries com h e a l t h a n d r e l a x a t i o n f o r l i f e IMPORTANT SAFETY INSTRUCTIONS READ ENTIRE MANUAL BEFORE INSTALLING SPA PLEASE SAVE THIS MANUAL OWNER S MANUAL...

Страница 2: ...TO CAN CSA C22 2 STD NO 218 1 DM Industries LTD 2350 N W 147 Street Miami FL 33021 305 685 5739 www dmindustries com Serial Number Model Number ID PLATES ARE LOCATED IN THE FRONT OF THE SPA A SMALL I...

Страница 3: ...____ ADDRESS ________________________________________________ ___________________________________________________________ TELEPHONE ______________________________________________ SERIAL ______________...

Страница 4: ......

Страница 5: ...or the Day 11 Badu Stream Jets II 11 V Stream Jets 11 Operating the Lights 12 Programming AquaBrite Chromatherapy 12 Operating the Stereo 12 SWIM OPERATION continued Swim Programming Instructions 13 S...

Страница 6: ......

Страница 7: ...nded for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibl...

Страница 8: ...e cover on Extended hi speed pump operation will cause a slow heat build up due to water friction which could trip the spa s hi limit thermostat DO NOT DIVE INTO SPA SAVE THESE INSTRUCTIONS SITE SELEC...

Страница 9: ...t all times when not in use DANGER RISK OF INJURY To reduce the risk of potential injury 1 Never leave a spa uncovered or unattended 2 Never leave a spa cover unlocked 3 Do not stand sit or lie on the...

Страница 10: ...817G2 817G1 817G3 2 ea 0212318 2 ea 0532064 Cascade Cover Plate 0663005 1 ea 0212305 TRB 2 ea 0532064 1 ea 0212318 2 ea 0212318 DRAIN DRAIN DRAIN DRAIN PAGE 4 NO DIVING TILES...

Страница 11: ...tened water Never fill the spa entirely with softened water GFCI The GFCI is a very important safety device and the National Electric Code requires that all spas are GFCI protected The GFCI shuts off...

Страница 12: ...or in heating mode it will immediately restart running at low speed to filtrate and or heat the water This button controls the LED lights The first press turns the underwater light on Second press tur...

Страница 13: ...ry to run on AutoHeat mode every day of the week That means whenever the temperature of the water falls 1 F 0 5 C below the set temperature the ICSTM control will start the heating cycle and run it un...

Страница 14: ...to cycle through the program until the display shows hd A again Then repeat steps 1 through 3 to do the same for Wednesday hd 4 Tuesday hd 3 and Monday hd 2 NOTE If you programmed different temperatu...

Страница 15: ...o follow button commands incorrectly A3 POWER SERVICE LEVEL The Therapy side of the xStream Duo Pro should be set to S 0 ONLY This indicates that the heater will shut off when the pump is turned on hi...

Страница 16: ...ef description of each button is as follows Button Not active Pressing this button will cycle the therapy jets through a soothing soaking mode to an invigorating therapy mode and then off Not active P...

Страница 17: ...d creates a unique invigorating bubble bath effect It will also add additional resistance to swim against BADU STREAM II s adjustable flow nozzle enables swimmers to regulate the volume of water relea...

Страница 18: ...Colors Red Blue L 10 Music Stereo must be on to work The lighting system will automatically turn itself off after three 3 hours SURROUND STEREO OPTIONAL The stereo option allows you to listen to FM s...

Страница 19: ...how the heat day Press again until the desired heat day is selected 2 Press to display temperature for the day selected Press and hold to lower temperature to for instance to 80 F 27 C Press to increa...

Страница 20: ...ess to remove the Heat Lock of the heater Notice that the lock icon will disappear All spa functions including temperature adjustment will be accessible G PANEL LOCK The ICSTM controller also allows y...

Страница 21: ...uld be set to S 0 ONLY This indicates that the heater will shut off when any pump is turned on high speed except for the filtration circulation pump Warning Changes to this setting may cause inadverte...

Страница 22: ...For cleaning purposes these jet faces can be removed by grabbing outer face and pulling away from jet body Re install it by pushing the face back in place B DIRECTIONAL MASSAGE JETS When the pump is...

Страница 23: ...If you cannot pinpoint the cause Call Your Dealer for technical assistance C OVERHEAT PROTECTION If a malfunction occurs and the spa water temperature reaches 44 5 C 112 F the pump and heater will tu...

Страница 24: ...id the surface warranty of the spa COVER MAINTENANCE Your cover is manufactured from a durable marine grade UV resistant material Even so monthly cleaning and periodic con ditioning is recommended to...

Страница 25: ...s properly evacuated this is not nec essary 3 Loosen and remove the union connections to your spas heater and pumps this will allow standing water in these components to further drain 4 To further ens...

Страница 26: ...ll Electrician if it will not start Clean change filter element see page 4 for filter part numbers Check pump for flow on therapy side check low speed running On swim side check circ pump running If F...

Страница 27: ...k Programming Instructions or Prime cycle at startup P Yes No Notice When set to P Pr pumps run for 2 minutes every time power is fed to the spa U US E Europ e Switches clock between 12h and 24h Clock...

Страница 28: ...Rev Date 10 9 2008 Not Applicable should be set to b Power Service Level MUST BE S 0 DO NOT CHANGE Warning Changes to this setting may cause inadvertent breaker tripping and strain your power connect...

Страница 29: ......

Страница 30: ...JECT TO CHANGE WITHOUT NOTICE DM Industries Ltd 2320 Northwest 147th Street Miami Florida 33054 Email customercare dmindustries com and techhelp dmindustries com www dmindustries com MIAMI FLORIDA DM...

Отзывы: