Страница 1: ...h e a l t h a n d r e l a x a t i o n f o r l i f e GRAPHIC SERIES OWNER S MANUAL VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Страница 2: ......

Страница 3: ...____________________________________ TELEPHONE ___________________________________________ SERIAL ______________________________________________ MODEL _____________________________________________ To...

Страница 4: ......

Страница 5: ...16 F Cluster 16 G Tension Ease 16 H Air Control 17 I Waterfall Operation 17 J Aromatherapy Injector 17 VitAroma Therapy System 18 Water Purification System 19 Sparkle Clear 19 SPA MAINTENANCE Filter M...

Страница 6: ......

Страница 7: ...nance We suggest that you take some time to carefully review it Please keep this manual available for reference If you have any questions regarding your Vita Spa set up operations or maintenance pleas...

Страница 8: ...r attached to the wire connector on the terminal box that is provided for this purpose National Electrical Code ANSI NMFP A70 1993 DANGER RISK OF ELECTRICAL SHOCK Do not permit any electrical applianc...

Страница 9: ...than normal body temperature can result in a dangerous condition known as HYPERT HE RMIA The causes symptoms and effects of hyperthermia may be described as follows Hyperthermia occurs when the intern...

Страница 10: ...mended The wire size for the distance of the wire run must conform to NEC and local electrical codes 5 To ensure proper connections use copper conductors only DO NOT USE ALUMINUM WIRE 6 The spas power...

Страница 11: ...wn straps Utilizing the cover anytime the spa is not in use will reduce heat loss and thereby reduce the amount of running time required to make up that loss by the heating system Keep cover fastened...

Страница 12: ...f the newest a latest technological topside control for hot tub performance and personal comfort Before we start getting to know the operations of the topside control let s go over a few things The si...

Страница 13: ...to 30 seconds to be completed If at anytime you choose to change your viewing setting to the factory default merely press RESET to return to the default settings So now let s go back to the beginning...

Страница 14: ...p to view directions for this screen Press Back to return to Mood display Press LIGHTS to cycle through light sequences Use ON OFF button to activate lights Use ARROWS to select color The upper right...

Страница 15: ...GE 9 Press MEDIA to enter stereo mode Use BACK to return to MOOD display Use SOURCE to cycle through Line TV AM and FM Use SELECT to change from media to VOLUME to BASS Use ARROWS to adjust accordingl...

Страница 16: ...THERAPY to operate the pumps Press SOA K to operate Low Speed on pumps 1 and 2 Press JET 1 to operate high speed pump 1 Press JET 2 to operate high speed pump 2 Press JET 3 to operate high speed pump...

Страница 17: ...N LOCK SPA FEHRENHEIT CELCIUS COUNTRY CODE Press SETUP to enter section Use UP and DOWN arrows to cycle past the selections Use the SELECT key to choose your selection then adjust accordingly Press BA...

Страница 18: ...layed on main screen The name entered and all your own personal setting are saved on the system The set programming name setting will appear on screen in the WELCOME area The set programming name sett...

Страница 19: ...will flash RUN SELF TEST will flash on your screen You then press MAINT to enter the maintenance mode you will have to be in Press STATUS to view status of pump setting amp draw and other settings St...

Страница 20: ...Press MAINT to enter servicing section Press TEST to enter systems check Press BEGIN to start 4 00 minute countdown for testing Error Problem found will display ALL GOOD No problems found PAGE 14...

Страница 21: ...outer rim of the jet s clockwise for minimum pressure and counter clockwise for maximum pressure Pressure may also be varied by the use of the air control This jet can be removed for cleaning by turni...

Страница 22: ...rimary or secondary two speed pumps are operating Water may be diverted to two individual sections of jets or a combined operation of both sections Do not adjust when pump is set at high speed For the...

Страница 23: ...ed I WATERFALL OPERATIONS On the Nuage and Romance model spas This valve increases or decreases volume of water from the waterfall On the Nuage a second valve of this type increases or decreases the v...

Страница 24: ...nsert one of Vita Spa s exclusive aromatherapy scents and turn on the VitAroma Induction System The system is activated when the air blower button is depressed This system dispenses aromatherapy throu...

Страница 25: ...ines shock with a chlorine or bromine shock EVERY 4 MONTHS Drain and refill spa Replace SPARKLE CLEAR cartridge AS NEEDED If water looks hazy shock treat with 1 teaspoon of dichlor per 250 gallons NOT...

Страница 26: ...eaning while you continue to enjoy the use of your spa DRAINING YOUR SPA Detergent residues from bathing suits as well as soap film from your body may gradually accumulate in the water Foam inhibitors...

Страница 27: ...ay or with any glass cleaner DO NOT clean the surface with any type of abrasive as it will dull the surface and natural luster of the acrylic DO NOT use any type of oil based solvent Such products can...

Страница 28: ...filled or refilled a pump is operating but the water is not flowing from any of its jets This is a sign that the pump did not properly prime To correct please perform the following 1 Turn off the pow...

Страница 29: ...esirable A two part bromine system or granular chlorine Dichlor are also acceptable sanitizers pH CONTROL pH is a measure of acidity and alkalinity of the spa water The recommended pH for spa water is...

Страница 30: ...prevent calcium build up Calcium hardness 120 to 250 ppm Spray filter element to remove loose particles MONTHLY Four to six weeks Two to three months Inspect and clean the spa filter cartridge It is i...

Страница 31: ...sits from staining the finish of your spa If your water is known to contain high concentrationsofthesemetalsit may benecessary to add an additional quantity of Spa Metal Inhibitor 3 Use a 3 Way Spa Wa...

Страница 32: ...s sanitizer Check and adjust Chlorine level if Chlorine is used TOOALKA L INE SCALING ZONE COMFORTZONE TOO ACIDIC CORROSIVE ZONE ADD pH DECREASER TO LOWERpH IDEAL ADD pH INCREASER TO RAISE pH 8 4 8 2...

Страница 33: ...issolves very slowly is highly concentrated and was designed for concrete or plaster swimming pools It will cause damage to your spa CHEMICAL SAFETY INSTRUCTIONS When using chemicals read labels caref...

Страница 34: ...gent Overused or old water Excessive organics Body oils and dirt Inadequate filtration SOLUTIONS Clean filter with a filter cleaner or degreaser Shock the spa with POTASSIU M PEROXY MONOSULFATE Increa...

Страница 35: ...Y MONOSULFATE maintain sanitizer at recommended level Raise pH with PH UP Shock with POTASSIUM PEROXY MONOSULFATE Maintain recommended sanitizer residual at all times super chlorinate Allow chlorine b...

Страница 36: ...use 3 and then verify that the blower motor is plugged in Check that HEET pump is plugged in Check that current sensor board is plugged into circuit board Replace fuse 1 or fuse 2 Replace heater High...

Страница 37: ...____________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________...

Страница 38: ...___ _____________________________________________________ _____________________________________________________ _____________________________________________________ __________________________________...

Страница 39: ......

Страница 40: ...ES ALL RIGHTS RESERVED DM Industries Ltd 2320 Northwest 147th Street Miami Florida 33054 Phone 305 908 8187 Toll Free 877 240 9457 MIAMI FLORIDA Vita International Division of Is a Registered Trademar...