![VISTEK V1638 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/vistek/v1638/v1638_user-manual_1033871009.webp)
VISTEK V1638 analogue audio
distribution amplifier
HU-V1638
9
3.
OPERATION
3.1
Front Panel
3.2
LED Indications
The green
V
+
LED is lit whenever power is applied and the V1630’s internal power supply is operating
correctly.
The yellow
REM
LED flashes briefly to indicate a DARTbus access is in progress.
A red
CLIP
LED is provided for each channel. These indicators have a fast attack and 0.8s retriggerable
hold characteristic. The output signal is monitored and the LEDs will trigger at +28dBu, just before the
onset of clipping. The LED will be on continuously of sustained clipping occurs.
A yellow
LO I
/
P
LED is provided for each channel. These have a slow attack, 0.8s, and fast decay
characteristic. The input signal is monitored and the LEDs will trigger when the signal level falls below
approx -40dBu for longer than 0.8s. The LED will be on continuously if there is no input or the input has
very quiet passages of long duration.