2.5 SWITCH

 

SETTINGS 

 
This table shows the use of the DIL switches, SW1 and SW2.  SW1 is exclusively for channel A and 
SW2 for channel B.  Note that to turn a parameter ON the switch should be pushed toward the front of 
the boards.  Ignore the ON indication on some of the actual switches which might imply the opposite. 
 

SWITCH 

TITLE 

ON (Front) 

OFF (Rear) - Default 

1 Std. 

Select  625/50 

 PAL N 

525/60 

 PAL M 

625/50 

 PAL I 

525/60 

 NTSC 

VI Blank 

Blank Vert. Interval on CVBS 

Pass Vertical Interval to CVBS 

DR Off 

Dynamic Rounding disabled 

Dynamic Rounding ON 

NTSC - Japan 

NTSC JAPAN for 525/60 i/ps 

Standard NTSC for 525/60 i/ps 

5 unused 

 

 

6 unused 

 

 

PLUGE Disable  PLUGE not selectable 

PLUGE available 

YC on Output 

Analogue O/Ps 

 Y and C 

Analogue O/Ps  

 CVBS 

 
For normal operation all switches should be OFF, i.e. set towards the rear. 

3. OPERATION 

 

3.1 FRONT

 

PANEL

 

LAYOUT 

 
The V1629 front panel layout is as shown here. 
 

REM

+V

Local

Rem

V1629

Dual Monitoring
DAC

Remote Control Access and Power indicators

Operating Standards for A and B (green)

REMOTE/ LOCAL control selection

PAL I

PAL N

NTSC

PAL M

YC

Test Signal

ON

OFF

A

B

A

B

A

B

A

B

A

B

Analogue Output Type (CVBS or YC) (amber)

Local Selection & Global Indication of PLUGE

 

 

 

Содержание V1629

Страница 1: ...AL MONITORING ENCODER INSTALLATION and OPERATION Vistek Electronics Ltd Filename V1629om doc Issue A Date December 2000 VISTEK Electronics Ltd Wessex Rd Bourne End Buckinghamshire SL8 5DT ENGLAND Tel...

Страница 2: ...M Which standard is used can be set locally on a DIL switch on the PCB or remotely over the DART remote control system The two channels are quite independent and can be operating in either the same or...

Страница 3: ...RCE COMMENTS POWER The Rack 7 5W SDI A I P SD IN Sourcing cable length up to 200m SDI A O P Reclocked version of SDI A Driving cable length up to 200m CVBS A1 Colour Composite or Y Channel A CVBS or Y...

Страница 4: ...e FLEX device U20 FRONT PANEL REAR CONNECTOR PROM SW1 U27 FS1 1 8 U16 uP A SW2 1 8 U28 uP B VR1 VR2 VR3 VR4 VR5 VR6 on off off on 2 4 ADJUSTMENTS The drawing in section 2 3 shows 6 variable resistors...

Страница 5: ...to CVBS 3 DR Off Dynamic Rounding disabled Dynamic Rounding ON 4 NTSC Japan NTSC JAPAN for 525 60 i ps Standard NTSC for 525 60 i ps 5 unused 6 unused 7 PLUGE Disable PLUGE not selectable PLUGE avail...

Страница 6: ...nt panel indication whether it is standard NTSC or the Japanese variant which has no setup 3 2 4 TEST SIGNAL The normal Test Signal available is PLUGE and this is used in all other parts of this manua...

Страница 7: ...60 NTSC 2 VI Blank 625 623 5 22 311 335 625 623 5 6 311 320 525 1 20 263 5 19 525 1 9 263 5 9 3 DR Off Dynamic Rounding disabled Dynamic Rounding ON 4 NTSC Japan 625 no effect 625 no effect 525 NTSC...

Страница 8: ...uch as the V1608 The DART map of all available controls is shown in section 3 12 3 7 PLUGE PLUGE is a monochrome test signal to assist in the setting up of picture monitors It contains two parts low l...

Страница 9: ...there will be no output All analogue outputs are switched off to a dc level For the Coder outputs this is in the region of the sync tips approximately 300mV For the YC outputs if selected the dc volt...

Страница 10: ...ng at the C output with the unit set to YC Wrong colour standard Set incorrectly on the DIL switch or over DART Wrong level in NTSC Probably caused by the unit being set to Japanese NTSC on the intern...