background image

VISTEK V1626 digital to analogue 

converter 

 

 

 

 

Issue 1

 

2. 

INSTALLATION 

 

2.1 

Introduction  

 
This  section  gives  information  on  installing  the  V1626  DAC  modules  into  the  V1601  and  V1603  interface 
frames and details on the connections which can be made to it. Information is also supplied on the function 
of each Preset adjustment and switch which are made available to the user on the front panel. 
 

2.2 

Installing Modules  

 
The V1601 and V1603 frames are normally supplied with modules fitted. However, if further modules are to 
be fitted to a part loaded unit follow the instructions below. 
 

Rear (I/0) modules 

 
Remove  the  screws  from  the  blanking  plate  covering  the  spare  position  at  the  rear  of  the  equipment  and 
remove the plate. Place  the new rear module in frame and slide into the unit until the connector(s) mates. 
The connector panel on the rear module should be seated flush with the rear cross extrusions of the frame 
when inserted correctly. Screw the module to the rear cross extrusions with the screws provided. 
 

Front modules 

 
Withdraw the front panel of the frame and fold it down. Place the new front module in the card guides (take 
care  to  insert  the  circuit  board  into  the  runners  and  not  the  screen  plate)  and  slide  into  the  frame  until  it 
mates with the rear module. Close the front panel. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание V1626

Страница 1: ...1 VISTEK V1626 DIGITAL TO ANALOGUE CONVERTER USER GUIDE www pro bel com...

Страница 2: ...Controls 6 3 ON BOARD CONTROLS ADJUSTMENTS 7 3 1 Main Board 7 3 2 Matrix Sub board 9 4 CALIBRATION OF V1626 DAC MODULE 10 4 1 Introduction 10 4 2 Test Equipment 10 4 3 Environmental 10 4 4 Calibration...

Страница 3: ...hese may be configured as either an extra set of Y Pb Pr or three spare serial SDI outputs Remote control interface is available for communication between modules within the frame and others outside i...

Страница 4: ...unit follow the instructions below Rear I 0 modules Remove the screws from the blanking plate covering the spare position at the rear of the equipment and remove the plate Place the new rear module i...

Страница 5: ...y terminated with 75 Ohms The Serial Digital Input should be connected to this BNC Serial Digital Output SD1 OUT Active loop through output from SD IN Serial Digital Outputs SD2 OUT SD4 OUT Serial dig...

Страница 6: ...m communications link is accessing the module The 525 lamp indicates that the unit is working in 525 mode and is locked to 270 Mb s serial digital input signal The 625 lamp indicates that the unit is...

Страница 7: ...S 3 1 Main Board Locations of switches and Preset potentiometers are shown in the figure below To gain access to these controls and adjustments the board must be removed from the chassis If the adjust...

Страница 8: ...b c Sub module output if fitted YPbPr outputs from main board SW5 Up b c Down a b Spare Y N10 output Spare re clocked SDI output SW6 Up b c Down a b Spare Pb N10 output Spare re clocked SDI output SW...

Страница 9: ...evel Pb and Pr are not adjustable on the sub board VR5 adjusts the pedestal on the 525 Betacam signal VR2 VR3 and VR4 adjust the G B R output levels Switch Position Function SW1 b c a b Syncs on Green...

Страница 10: ...ment 100 MHz dual channel oscilloscope Tektronix TSG 422 10 bit serial test signal generator Tektronix WFM601i Serial signal analyser Tektronix 1781 test set Digital multimeter Standard RS trim tool 4...

Страница 11: ...pe adjust VR5 VCO centre frequency until lock is achieved without data errors A method for setting the VCO centre frequency is described in the Gennum 1994 Data book page 2 47 Tune the potentiometer V...

Страница 12: ...st the syncs amplitude pot VR7 for 300 mV p p of syncs Monitor the Pb output using the 1781 measurement set Adjust the front panel Pb gain control pot VR3 for an amplitude of 700 mV peak to peak Monit...