IMPORTANT SAFEGUARDS 

 
1.   READ AND RETAIN INSTRUCTIONS 

      Read the instruction manual before operating the equipment.   
 

Retain the manual for future reference. 

2.   CLEANING     

Turn the unit off and unplug from the power outlet before cleaning. Use a damp cloth 
for cleaning. Do not use harsh cleansers or aerosol cleaners. 

3.   ATTACHMENTS     

Do not use attachments unless recommended by manufactured as they may affect 
the functionality of the unit and result in the risk of  fire, electric shock or injury. 

4.   MOISTURE   

     

      Do not use equipment near water or other liquids. 

5.   ACCESSORIES     

Equipment should be installed in a safe, stable location. Any wall or shelf mounting 
accessory equipment should be installed using the manufacture's Instructions.  Care 
should be used when moving heavy equipment. Quick stops, excessive force, and 
uneven surfaces may cause the equipment to fall causing serious injury to persons 
and objects. 

6.   VENTILATION 

Openings in the equipment, if any, are provided for ventilation to ensure reliable 
operation of the unit and to protect if from overheating. These openings must not be 
blocked or covered 

7.   POWER SOURCES 

The equipment should be operated only from the type of power source indicated on 
the marking label. If you are not sure of the type of power supplied at the installation 
location, contact your dealer. For equipment designed to operate from battery 
power, refer to the operating instructions. 

8.   GROUNDING OR POLARIZATION 

Equipment that is powered through a polarized plug (a plug with one blade wider 
than the other) will fit into the power outlet only one way. This is a safety feature. If 
you are unable to insert the plug fully into the outlet, try reversing the plug. Do not 
defeat the safety purpose of the polarized plug. 

Alternate Warning:

  If the equipment is powered through a three-way grounding-

type plug, a plug having a third (grounding) pin, the plug will only fit into a grounding-
type power outlet. This is a safety feature. Do not defeat the safety purpose of the 
grounding-type plug. If your outlet does not have the grounding plug receptacle, 
contact your local electrician. 

9.   CORD AND CABLE PROTECTION 

Route power cords and cables in such a manner to protect them from damage by 
being walked on or pinched by items places upon or against them. 

10. LIGHTNING   

For protection of the equipment during a lightning storm or when it is left unattended 
and unused for long periods of time, unplug the unit from the wall outlet. Disconnect 
any antennas or cable systems that may be connected to the equipment. 

 

This will prevent damage to the equipment due to Lightning or power-line surges. 

11. OVERLOADING     

Do not overload wall outlets and extension cords as this can result in a risk of fire or 
electric shock. 
 

Содержание VFD28V12CM960H

Страница 1: ...Set up and user manual for the VFD28V12CM960H U VFD28V12DN960H Cameras Installation Manual MManualManual...

Страница 2: ...i...

Страница 3: ...maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions please contact Norbain Technical Support and Sales Norbain SD Ltd...

Страница 4: ...eeled bin mark symbolizes that within the European Union the product must be collected separately at the product end of life This applies to your product and any peripherals marked with this symbol Do...

Страница 5: ...pplied at the installation location contact your dealer For equipment designed to operate from battery power refer to the operating instructions 8 GROUNDING OR POLARIZATION Equipment that is powered t...

Страница 6: ...rmance 14 REPLACEMENT PARTS When replacement parts are required be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the origina...

Страница 7: ...E OF CONTENTS INTRODUCTION 7 CONTENTS OF PACKAGE 8 BASIC INSTALLATION 8 TACT SWITCH OPERATION SERVICE JACK 11 OSD MENU STRUCTURE 12 DEAD PIXEL CORRECTION 20 LENS ADJUSTMENT 20 DIMENSIONS 21 SPECIFICAT...

Страница 8: ...onochrome OSD On Screen Display via tact switch ATR Adaptive Tone Reproduction AGC Auto Gain Control NR function 2DNR Digital Noise Reduction Auto and manual white balance modes BLC Back Light Compens...

Страница 9: ...ipment The content of the package includes 1 Camera 2 Fixings 3 Instruction manual 4 Template sheet 5 DC Jack BASIC INSTALLATION 1 Make mounting holes and cable hole in the place ceiling to which this...

Страница 10: ...r cables are properly arranged in the cable notch 6 Insert the camera module remove the liner 7 Adjust the camera module to the area you want to view then adjust the zoom and focus to suit 8 Carefully...

Страница 11: ...10 Ceiling Wall Mounting Template sheet Plastic anchor Dome Base Mounting Screw Camera Module Liner Dome Cover Tapping screw...

Страница 12: ...centrally on the joystick and navigate using the up down left and right actions If there is an arrow to the right of the menu function this denotes that there is an accessible sub menu function The wh...

Страница 13: ...ALL LENS AUTO IRIS MANUAL RETURN WHITE BALANCE ATW PUSH USER 1 USER 2 ANTI CR MANUAL PUSH LOCK RETURN BACKLIGHT BLC HLC RETURN PICTURE ADJUST MIRROR BRIGHTNESS CONTRAST SHARPNESS HUE GAIN RETURN SHUT...

Страница 14: ...E ALL PRIVACY AREA SEL COLOUR TRANSP MOSAIC RETURN DAY NIGHT AUTO COLOUR B W RETURN RETURN NR NR MODE Y LEVEL C LEVEL RETURN RETURN CAMERA ID titling RETURN RETURN LANGUAGE ENGLISH GERMAN FRENCH RUSSI...

Страница 15: ...High Luminance Mode Shut Shut Auto Iris Auto Iris Shut can only be selected if the lens is set to Manual mode Brightness 0 to 255 increments of 1 Adjusts the brightness of the image Low Luminance Mod...

Страница 16: ...ications B Gain 0 to 255 increments of 1 R Gain 0 to 255 increments of 1 Anti CR When shut auto iris mode used this setting can reduce but may not eliminate colour roll caused by fluorescent lighting...

Страница 17: ...4 areas of motion to be set up note there is no output Detect Sense 0 127 increments of 1 Sets the motion detection sensitivity 0 low sensitivity 127 high sensitivity Block Disp Off On Enable Applies...

Страница 18: ...s switch to a non adjustable mosaic tile distortion effect For full mosaic Transp needs to be set to 0 00 DAY NIGHT Day Night make changes to the camera operation Modes Auto colour B W Ext1 Ext2 Auto...

Страница 19: ...e from the image in low light conditions when AGC is applied NR mode Off Y C Y C Sets the 2D NR filter mode Y Level 0 15 increments of 1 Sets the Y filter Luminance strength C Level 0 15 increments of...

Страница 20: ...English EN German DE French FR Russian RU Portuguese PT Spanish ES CAMERA RESET CAMERA RESET Returns the camera to the factory default settings EXIT SAVE ALL EXIT Exits the menu and does not save chan...

Страница 21: ...s then cover the lens and push ENTER central push on the OSD tact switch then follow the instructions on the screen Please note If there are over 65 dead pixels the camera will not run the DPC functio...

Страница 22: ...e Window Spec Thick t 0 05 in 2 0 mm Material Polycarbonate Diameter 3 15 in 80 0 mm Bottom Case Thick t 0 18 in 3 0 mm Material Polycarbonate Diameter 3 98 in 101 2 mm Cable Entry One 1 opening hole...

Страница 23: ...L LM M MH H Backlight Off BLC HLC PWI Day Night Auto Colour B W with IR optimizer White Bal ATW Push AWB User1 User2 Anti CR Manual Pushlock Motion Det 4 areas Privacy 8 zones with 8 selectable colou...

Страница 24: ...23 VFD960H_U Manual V1 0 2013 02 22 subject to change without notice...

Отзывы: