Vista Dental Products Terms and Conditions of Warranty

The operator assumes all risk and liability for damages arising out of the 

improper use of the VALIANT™ curing light. In the event of a defect in material 

or workmanship, Vista Dental Products is limited, at its option, to replace of 

the defective product, a part thereof, or reimbursement of the actual cost of 

the defective product. In order to take advantage of this limited warranty, the 

defective product must be returned to Vista Dental Products.

The VALIANT™ handpiece is warranted to be free from defects under normal 

usage conditions for 3 years of its date of delivery; the batteries for 1 year. 

There is no warranty, expressed or implied, of merchantability or fitness. The 

manufacturer’s sole obligation under this warranty is to opt to either repair 

or replace the defective part(s) or product. If service must be performed to 

correct a defect, then the manufacturer will provide the service at its factory 

according to the mutual agreement made in advance. The manufacturer and 

its distributors will not accept the return of the product unless the return is 

authorized and shipped in accordance with the manufacturer’s instructions. 

Contact the local representative of the distributor or if purchased directly 

from the manufacturer for shipping instructions, a return authorization 

number, and ARS shipping label. There is no warranty, remedy or condition, 

expressed or implied, except as provided herein. The warranty and remedies 

contained herein are made by the manufacturer to the first buyer for dental 

use and are in lieu of all other agreements (expressed or implied), liabilities or 

remedies for breach of warranty. Vista Dental Products shall not be liable for 

consequential or incidental damages. No person or distributor is authorized 

to modify the terms of this warranty.

This warranty is void if any defect is caused by conditions beyond the 

manufacturer’s control, including acts of God, damage resulting from 

mishandling, neglect, misuse, improper maintenance, accident or alteration/

repair by anyone other than the manufacturer. The buyer assumes all liability 

for any damage caused by improper use of the product. The manufacturer 

assumes no liability for the user’s failure to follow the instructions contained 
in this manual. 

18

Содержание Valiant 601000

Страница 1: ...ly and understood prior to using theVALIANT Curing Light 601000 601000 I V 17 ENG 6 Inter Med Inc 2200 South St Racine WI 53404 2500 U S A Tel 1 262 636 9755 Fax 1 262 636 9760 Toll Free 1 877 418 4782 www vista dental com Emergo Europe Prinsessegracht 20 2514 AP The Hague The Netherlands ...

Страница 2: ...y Pack 7 VALIANT Operation 8 Curing Modes 8 Quick Curing Guide 8 Transillumination Mode 9 Disinfection Sterilization 9 Infection Control Measures 9 Routine Maintenance 10 Troubleshooting Guide 10 Technical Data 11 Symbol Identification 12 Battery Pack Disposal 13 Safety Notes Warnings and Precautions 13 16 Operating Conditions and Safety Consideration 17 Heat generation 17 Safety Eyewear 17 Advers...

Страница 3: ... materials making it one of the most versatile curing lights on the market The VALIANT will greatly enhance the way you cure polymerized light cured dental materials and is lightweight easy to use and most importantly clinically effective The Vista Dental Products website www vista dental com also provides information on new products accessories and educational assistance for you and your professi...

Страница 4: ...d be inspected upon arrival for evidence of shipping damage Damaged packaging may indicate the presence of an unsafe product and the product should not be used until carefully inspected If the package or product is damaged please contact Vista Dental Products at 877 418 4782 Toll Free as well as the delivery service to file a complaint Introduction to the VALIANT Please reference the image below t...

Страница 5: ...cap in the wrong orientation The battery pack should be easy to insert To ensure proper mating of the battery pack with the handpiece the anti roll bumps on the battery pack should be on the same side as the ON OFF button Attaching and Removing the Barrier Sleeve 1 Insert the head of the VALIANT Curing Light into the opening on the bottom of the barrier sleeve 2 Slide the barrier sleeve onto the V...

Страница 6: ...ith the unit s neck and pressing firming until the shield clicks on see image below 2 To easily remove the shield peel the shield towards the tip head of the unit The shield should easily pop off 6 Area to snap on off the curing light shield Press firmly on the shield until it snaps onto the unit Peel towards head Shield will easily disengage itself ...

Страница 7: ...pulsate Once charging is complete the light on the charging base stop pulsating and remains lit The handpiece is designed to display the battery state to the user via the battery indication ring When the battery pack is greater than 50 the indication lights will blink Green during use When the battery pack is between 20 50 the indication lights will be solid Red during use It is advised to charge ...

Страница 8: ...llustrates the various curing settings on the rotation knob NOTE Curing time may need to be adjusted due to composite shade depth of layer if over 2mm NOTE These are default curing durations for the VALIANT curing light Follow composite dental material manufacturer s guidelines for required curing durations and irradiance values NOTE Software will automatically turn the VALIANT handpiece off if le...

Страница 9: ... use abrasive material such as scouring powder organic solvents or solvent based cleaning fluids In case of severe contamination gently clean the device by using diluted alcohol Store the device in the box if it is not to be used for an extended period of time Disassembly is not required when cleaning the handpiece and charging base Infection Control Measures CAUTION To prevent cross contamination...

Страница 10: ...battery pack and inspect for any defects if none are found reconnect the battery pack A beep should be heard when the battery pack is inserted 1 Verify the unit provides adequate optical power using a radiometer 2 Verify that the appropriate curing mode is selected 3 With the handpiece turned off and battery pack removed inspect the lens for residual cured composites resins 4 Check expiration date...

Страница 11: ... been designed solely for short term operation Typical operating time at room temperature 23 C 3 20 sec depending on mode per layer of composite Temperature 10 C 40 C 59 F 104 F Atmospheric Pressure 697hPa 1013hPa 10 C 40 C Transport and Storage Conditions Temperature 20 C 40 C 4 F 104 F 20 C 40 C Relative Humidity 30 90 non condensing 30 90 max Atmospheric Pressure 500hPa 1400hPa 500 hPa 1400 hPa...

Страница 12: ... Protected Class II Electrical Insulation Type BF Applied Part Keep Dry Part Number CE Marking Warning Caution Temperature Limitation Humidity Limitation Atmospheric Pressure Limitation Batch Code Lot Number Authorized European Representative Do Not Dispose Of Follow instructions for use Perscription Only ...

Страница 13: ...nly be used as indicated in this manual Saftey Notes The VALIANT Curing Light is a medical device which is subject to IEC 60601 1 EN 60601 1 and EMC directives IEC 60601 1 2 EN 60601 1 2 Edition 3 0 as well as the 93 42 EEC Medical Device Directive The curing light complies with the relevant EU regulations The curing light has been shipped from the manufacturer in a safe and technically sound cond...

Страница 14: ...available DO NOT look directly into the light output The light attenuating shield should always be used Additional eye protection is suggested DO NOT expose soft oral tissues at close proximity Maintain a safe distance between the lens and the soft tissue If using the VALIANT curing light in the Standard Mode and in close proximity of the gingival tissue DO NOT expose tissue for more than 20 secon...

Страница 15: ...s and accessories listed in the instructions associated with the device Failure to do so will void the warranty may decrease the performance and may lead to unsafe operation In order to avoid electric shock do not introduce any objects into the device or remove the device enclosure Should you have any reason to suspect the safety of the device to be compromised the device must be taken out of oper...

Страница 16: ...frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference with other devices which can be determined by turning the device off and on the user is encouraged to try to cor...

Страница 17: ...uring light extremely carefully and comply with all the necessary safety precautions including wearing suitable light filtering safety glasses Anyone who has had a cataract operation may be especially sensitive to light and should be advised against undergoing treatment with a VALIANT curing light unless adequate safety precautions are taken such as wearing suitable light filtering safety glasses ...

Страница 18: ...ibutors will not accept the return of the product unless the return is authorized and shipped in accordance with the manufacturer s instructions Contact the local representative of the distributor or if purchased directly from the manufacturer for shipping instructions a return authorization number and ARS shipping label There is no warranty remedy or condition expressed or implied except as provi...

Страница 19: ...e date Return Stock Policy Any equipment returned within 30 days from the date of the original shipment from Vista Dental Products may not be assessed a restocking fee as long as the merchandise has current labeling and unopened non soiled packaging Unopened equipment returned within 31 60 days from the date of the original shipment from Vista Dental Products requires a restocking fee of 25 of the...

Страница 20: ...turer s Declaration Electromagnetic Immunity The VALIANT Curing Light is intended for use in the electromagnetic environment specified below The customer or the user of the VALIANT Curing Light should assure that it is used in such an environment HP MGMGH H I5 J8G8 2 8 3 8 0 J MGMGH H I8 08 8 7 HH H 2 2 8 5 2 0 2 2 2 8 HH 5 2 0 0 2 0 MHGGG J I MHGGG J J 7 MGMGH H I5 J8G8 3 8 08 8 B B 7 MHGGG K I X...

Страница 21: ...ects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broad cast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strengt...

Страница 22: ...nded Separation Distances Between Portable and Mobile RF communications equipment and the VALIANT Curing Light The VALIANT is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the VALIANT can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipme...

Страница 23: ...__________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Страница 24: ......

Отзывы: