Input Configuration Recall
This command loads a previously saved input configuration onto the video source of
a specified layer ID.
•
Command:
ICR
•
Argument 1:
Configuration ID. This is the ID number to store the layer ID’s
current input configuration to. Set the Configuration ID to -1 to force auto sync.
•
Argument 2:
The layer ID to apply the specified input configuration to.
Input Config Learn
This command saves the input configuration for a specified layer ID, to a specified
input configuration ID for later recall.
•
Command:
ICL
•
Argument 1:
Input configuration ID to save to.
•
Argument 2:
Layer ID to save configuration information from.
Restart Spyder Server
This command allows the user to remotely restart the server application remotely.
•
Command:
SDN
•
Argument 1:
0 = Power Off, 1 = Restart
Force Server Save
This command forces the remote Spyder frame to flush all configuration and user
data changes to non-volatile storage.
•
Command:
SAV
Recall Script Cue
This command recalls an existing script at a specified cue. Use ‘Vista Advanced’
software interface to build script.
•
Command:
RSC
•
Argument 1: Script ID to recall
•
Argument 2: Script Cue to recall
Transition Layer(s)
This command transitions layers on and off of their currently assigned PixelSpace.
•
Command: TRN
•
Argument 1: 0 = Mix Off - 1 = Mix On
•
Argument 2: Transition Duration (in frames)
•
Argument 3 ~ XX: Layer ID to transition
Layer Size Change
This command sets the horizontal size of one or more specified layers. Vertical size
adjusts automatically to ensure the layer’s aspect ratio.
•
Command:
KSZ
•
Argument 1: Horizontal Size (in pixels)
•
Argument 2 ~ XX: Layer ID to set size