![Vista 6216 Landscape Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/vista/6216-landscape-series/6216-landscape-series_installation-instructions_1033556002.webp)
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
SPRING LOADED
LOCKING PIN
FIXTURE TOP
LOCKING RING
MALE CONNECTOR
FIXTURE BASE
FIELD REPLACEABLE
LED ENGINE
FEMALE CONNECTOR
SPT-1 CABLE
LOCKING PIN IN UNLOCKED POSITION.
ROTATE 90° CLOCKWISE TO LOCK.
PRISMATIC HIGH-IMPACT
POLYCARBONATE LENS
The operating voltage range for this LED luminaire
is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the first fixture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating
voltage range for each Vista luminaire, always consult factory’s specification sheet and/or installation instructions before installation.
6216 (07/14)
Stem
Main supply cable
Ground stake
Shade
Silicone filled safety
connectors
36” Pigtail
Path & Spread Lights
Landscape Series
6216
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING:
Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING:
Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE:
Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
See Reverse for Fixtures with
T3-LED or T3-Halogen
INSTALLATION INSTRUCTIONS -
For Integrated LED Module
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Disengage spring loaded locking pins.
3. Remove shade and lens assembly to expose LED engine.
4. Remove stainless steel locking/expansion ring.
5. Pull up field replaceable LED engine assembly.
6. Disconnect connector assembly.
7. Connect new field replaceable LED engine to connector assembly.
8. Reinstall LED engine and secure with stainless steel locking/expansion ring.
9. Reinstall shade assembly and secure spring loaded locking pins.
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until flange of stake is
flush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE:
Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
NOTE:
All luminaires orientation must be so that every part of the lampholder