www.vissonic.com
42 VISSONIC ELECTRONICS LIMITED
Chinese,
English,...(104
languages)
Auto floor
-
On/Off
On-The interpreter close the MIC on a channel, the
audio in this channel is switched to floor audio.
Off-The interpreter switch off the MIC and keep the
same audio output on the channel.
Channel lock
On/Off
On-The interpreter unit cannot be changed the
output channel.
Off-The interpreter unit can be changed the output
channel.
Booth setup
Max. booth
Start set
02 to 64
On/Off
Max. booth--set the booth quantity.
On--All interpreter units will show the booth
number for options. Press the MIC on interpreter
unit to select the booth no. The interpreter units in
the same booth should be the same.
Off--finish setting.
Note: The speakers of the interpreters will be off, if
turn on the MIC of interpreter in the same booth
6.1.5 Camera Auto-tracking Setup & Application
Use the menu items in 'Camera' sub-menu to set the Camera auto tracking relative setting.
Menu item
Parameter
Value
Description
Protocol
-
SAMSUNG,PELCO-D,V
ISCA,CUSTOM,
VCA-UDP
Select the protocol according to the camera model,
The value 'CUSTOM' mean the processor connect
the camera tracking controller
VIS-MSDI
and
the preset information is saved on the camera
controller and don't need to set the sub-menu '
Camera map
' and '
Start Set'
Camera map
(Note: If you use
the cameras using
SAMSUNG
or
PELCO-D protocol
need to set this
menu. Use VISCA
protocol, no need to
set this menu)
Camera select
Camera addr.
Video channel
UDP addr
001 to 016
Off,001to 255
Off,001 to 255
Off,001 to 255
Camera select
--select the camera to setup, there
totally support 16 cameras.
Camera addr.
--set the camera address for the
camera selected on submenu 'Camera select'.(if
SAMSUNG,PELCO-D need to set the
address, VISCA is not need
to set as Off)
Video channel
--Bind the camera(which set on
submenu 'camera select') to the video channel
number of video switcher, .(There are no video
switcher connected to the main unit for camera
tracking by RS232, just set as Off.)
Note:
To set next camera, we just repeat the same
Содержание CLEACON
Страница 14: ...www vissonic com 14 VISSONIC ELECTRONICS LIMITED Figure 2 5 Top view of wired and wireless unit 1 ...
Страница 15: ...www vissonic com 15 VISSONIC ELECTRONICS LIMITED Figure 2 6 Top view of wired and wireless unit 2 ...
Страница 34: ...www vissonic com 34 VISSONIC ELECTRONICS LIMITED ...
Страница 35: ...www vissonic com 35 VISSONIC ELECTRONICS LIMITED ...
Страница 36: ...www vissonic com 36 VISSONIC ELECTRONICS LIMITED ...