Visonic TOWER CAM PG2 TOWER CAM PG2 Скачать руководство пользователя страница 1

 

D-304493 TOWER CAM PG2

 

Installation Instructions 

 

TOWER CAM PG2

TOWER CAM PG2

TOWER CAM PG2

TOWER CAM PG2    

PowerG, Outdoor Mirror PIR Motion Detector with Anti-
masking and Built-In Camera

 

 

Installation Instructions

 

1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION    

The TOWER CAM PG2 is a 2-way, wireless outdoor digital mirror PIR 
detector  with  built-in  camera.  Activated  upon  PIR  detection  or  upon 
demand, the TOWER CAM PG2 sends clear images to the Monitoring 
Station for alarm image verification. 

The PIR motion detector’s features are as follows: 

  Operates with PowerMaster control panels (version 18 and higher) 

 

  Patented  8  independent  quad  PIR  detectors  (Octa-QUAD

operating  in  true  Quad  configuration  (patented)  with  true  motion 
recognition (TMR) processing for each of the 8 PIR detectors. 

  Advanced Obsidian Black Mirror

TM

 optics (patent pending). 

  Optimum performance even in poor weather conditions such as snow, 

rain, dust, wind and direct sunlight 

  Tamper protection prevents opening and removal from wall 

  PowerG  two-way  Frequency  Hopping  Spread  Spectrum  FHSS-

TDMA technology - provides robustness and reliability 

  Built-in link quality indicators enable installer to check signal quality 

without physically approaching the control panel. 

  Robust housing with recessed window. 

  Smart anti masking distinguishes between masking spray and rain. 

  Alarm LED is visible in sunlight. 

  Automatic termination of walk-test after 15 minutes. 

  Microprocessor-controlled temperature compensation. 

  Immunity to pets weighing up to 18 Kg (40lb) – see Table 1 

  Built-in swivel bracket 

The camera’s features are as follows: 

  Up to 10 cameras can be enrolled 

  Images multiplexed from all enrolled cameras 

  Color and black & white images 

  Auto-setup 

  Camera tuning by simple walk-test 

  Day and night CMOS camera, with near IR illumination. This allows 

taking pictures in full darkness without letting the intruder know. 

  Instant capture: guarantees capture of fast moving intruder. 

  Optional AC power 

  An event records 2 images per second. 10-15 images total  

Notes:

  

1. For UL/ULC installation, the camera feature is not to be enabled in UL 

listed product. 

2. Pet immunity is not evaluated by UL/ULC. 

A.

 IR LEDs 

 

B.

 Indication LED 

C.

 Camera 

D.

 External power LED 

E.

 Alarm LED

 

Figure 1. External View

 

2

2

2

2. 

. INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION    

2.1 Installation 

A. 

Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as 
possible to the surveyed ground surface. 

B.

  Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator 

position for various installation height and coverage distance combinations is detailed in Table 1. (The information refers to a relatively flat 
surveyed area. Verify the correct installation by walk-test.) 

C. 

Fasten the detector to the bracket (see Figure 2 step 4). 

Table 1 - Vertical Adjustment Reference 

Mounting Height 

Coverage Distance

 

2m / 6.7ft

 

4m / 13ft

 

6m / 20ft

 

8m / 26ft

 

10m / 33

 ft 

12m / 39 ft 

3.0m / 10 ft 

2.5m / 8 ft 

2.0m / 7 ft 

1.5m / 5 ft 

2

 

3

 

4

 

5

 

5

 

-

 

 

Содержание TOWER CAM PG2 TOWER CAM PG2

Страница 1: ...rature compensation Immunity to pets weighing up to 18 Kg 40lb see Table 1 Built in swivel bracket The camera s features are as follows Up to 10 cameras can be enrolled Images multiplexed from all enr...

Страница 2: ...re the installation options recommended for reducing the probability of false alarms from pets Event counter One region Correct Installation Incorrect Installation A Mark drilling point B Screw hole f...

Страница 3: ...installation and application It is recommended that the intrusion detection unit is not to be connected to an alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips...

Страница 4: ...Dispose of used battery according to the manufacturer s instructions Caution The battery used in this device may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 66...

Страница 5: ...her or not to activate the alarm LED indication Optional settings ON default and OFF PIR SENSITIVITY Define if the detector operates at regular or high PIR sensitivity or that at least one detection z...

Страница 6: ...ignal strength is not acceptable If you receive a poor signal from the detector re locate it and re test until a Good or Strong signal strength is received Note For detailed Diagnostics Test instructi...

Страница 7: ...o an outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this unit not expressly...

Страница 8: ...RECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUC...

Отзывы: