D-302415 

4. ENROLLMENT 

Refer to the PowerMaster-10 Installer Guide for the device enrollment procedure. 
 

5. CONFIGURATION AND OPERATION

5.1 Service Messages 

Five kinds of event codes are automatically included in a service 
transmission in addition to the repeater’s: 

O

 AC fail 

O

 Low Battery 

O

 End of life 

O

 Tamper 

O

 Supervision.  

Upon power failure, recharging stops and the backup battery takes 
over. It is therefore correct to assume that without power input the 
battery is gradually weakening and may be reported as “low”. 

Power / battery restore

 is reported only in the following test report. 

 

End of life 

is reported when battery power is depleted and device is 

about to shut down. 

Tamper restore

 is reported immediately upon occurrence. 

If the

 tamper

 or 

power failure

 condition persists long enough, 

respective alerts will be sent out again with each test report.

 

B

C

D

A

E

F

 

A.

 Siren. 

B.

 Motion detector. 

C.

 Door or window open/close detector 

D.

 Keyfob 

E.

 RP-610 PG2 Repeater 

F.

 PowerMaster-10 Control Panel 

Figure 3: Repeater Configuration

 

6. MAINTENANCE

Note:

 Battery replacement should be done by a service man. 

B

C

D

A

E

F

H

G

 

A.

 Turn & push battery 

B.

 Battery pack connector 

C.

 Connect the wires to the terminal block 

D.

 Self-Test button 

E.

 Enroll button 

F.

 AC connector terminal block 

G.

 Battery cable 

H.

 Battery 

Figure 4 - Battery Pack Insertion