Visonic PowerMax Partitions II Скачать руководство пользователя страница 3

3

Using Partitions in the Workplace

• 

The area in this example has 2 offices (accountant’s and solicitor’s)

• 

Each office runs independently with different working hours

• 

The reception area is shared by both offices

• 

Each area has a NEXT motion detector installed

The reception area is explained later in the ‘common area’ section

Accountants

Solicitors

Reception

Partition 1

Partition 2

Common area

Содержание PowerMax Partitions II

Страница 1: ...A quick start guide to PowerMax Partitions II Product Management Team April 2010 R...

Страница 2: ...p to three independently controllable areas whereby each can be in the HOME AWAY or DISARM state Each independent area is called a partition and has its own defined zones user codes etc Partitions pro...

Страница 3: ...icitor s Each office runs independently with different working hours The reception area is shared by both offices Each area has a NEXT motion detector installed The reception area is explained later i...

Страница 4: ...rtitions II Visonic s new version of partitioning now provides enhanced partitioning capabilities of the PowerMaxPro including Common areas Simultaneous control over multiple partitions Intuitive LCD...

Страница 5: ...isabled The first step is to enable Partitions II feature From the INSTALLER MODE select PARTITIONING and press Select ENABLE and press twice To avoid confusion and to make installation simpler it is...

Страница 6: ...elect the PARTITION option follows CHIME The screen will display P1 P2 P3 Black squares indicate the partitions to which the current zone is assigned Assign the zone to its proper partition or partiti...

Страница 7: ...itions defined by the master user during setup After selecting and defining user codes select the ACCESS TO PART menu to associate the user code with a partition or a partition combination Keyfobs are...

Страница 8: ...ll partitions associated with the code or keyfob simultaneously or an individual partition When using MCT 234 keyfob or the MCM 140 remote commander a user can only control all the associated partitio...

Страница 9: ...itions All partitions associated with the user code are Armed or Disarmed Arming a specific partition 1 Press 2 LCD will show SELECT PARTITION 3 Press 1 2 or 3 to select the partition 4 Press Arm or D...

Страница 10: ...an individual partition Arms Disarms all defined partitions Arming a specific partition 1 Press 2 In the LCD display a digit P1 P2 P3 will light to indicate the currently selected partition 3 Repeate...

Страница 11: ...office partition is disarmed the reception area must be disarmed This is called a Common Area Common Areas are used as walkthrough zones to multiple partitions There may be more than one Common Area...

Страница 12: ...one or a group of zones Example Accountants detector is assigned to the first Partition Solicitors detector is assigned to the second Partition Reception area s detector is assigned to both partitions...

Страница 13: ...at least one partition to which they are assigned is disarmed Interior zones Armed when all partitions they are assigned to are AWAY Disarmed if at least one partition to which they are assigned is H...

Страница 14: ...nt When one partition is armed AWAY and another armed HOME common area zones are armed HOME i e Interior zones will NOT give an alarm HOME AWAY HOME AWAY AWAY AWAY When all Partitions are armed AWAY c...

Страница 15: ...15 How Zones in Common Area Behave cont When even one partition is DISARMED all zones assigned to it including those in common areas are also disarmed AWAY HOME DISARM DISARM...

Страница 16: ...rming any one of the partitions to which that zone is assigned cancels the alarm and stops the siren Concurrent Alarms in different partitions When several zones are alarmed and each zone is assigned...

Страница 17: ...a common area initiates an alarm disarming one of the Partitions in that common area cancels the alarm and stops the siren 1 Alarm from zone in reception area AWAY AWAY ALARM 2 The first Partition is...

Страница 18: ...rtitions When the siren sounds due to the initiation of simultaneous alarms in two or more partitions the siren will stop only when all partitions with alarmed zones are disarmed 1 While siren is soun...

Страница 19: ...ation of simultaneous alarms in two or more partitions it will stop only when all partitions with alarmed zones are disarmed 3 Siren stops only when BOTH partitions are disarmed DISARM DISARM SIREN ST...

Страница 20: ...X Where X is the partition s status R Ready N Not Ready A Away H Home D Disarm E Entry Exit delay This partition is not used does not have zones assigned to it In case of TROUBLE or MEMORY LCD altern...

Страница 21: ...ns are HOME and none are AWAY OFF all partitions are DISARMED Trouble LED Reflects a trouble in the entire system not per partition More information in Reviewing Trouble Information in the User Manual...

Страница 22: ...the system HOME or AWAY from the keypad or the control panel will arm ALL partitions since user is not identified It is still possible to arm one specific partition by selecting a partition using the...

Страница 23: ...23 Force Bypass Setting affects all partitions Manual bypass The user can bypass zones assigned to any partition with which he she is associated Bypass options...

Страница 24: ...Thank You...