![Visonic MCR-308 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/visonic/mcr-308/mcr-308_installation-instructions-manual_1032953003.webp)
DE3191
3
No. of
Clicks
Sub-
Zone Flashing Sequence of the Yellow LED
One
1
st
—
—
.......
Two
2
nd
—
—
......
Three
3
rd
—
—
......
Four
4
th
—
—
......
= Flash;
— =
Pause
/HDUQLQJ7UDQVPLWWHU,'V
A single transmission is required to register a transmitter ID
in the MCR-308 memory.
A. Preparations
( 1 ) Prepare all the transmitters and mark each one with the
desired target zone output and sub zone location.
Note: In case of PIR detectors in which batteries are already
installed, cover the detector’s lens to prevent accidental
transmission during the learning session.
( 2 ) Remove the MCR-308 cover. The buzzer will beep once
upon release of the tamper switch.
B. Transmitter Learning Procedure
( 1 ) Set DIP switch SW-8 to ON (LEARN mode). The yellow
LED will flash at a constant rate throughout the learn period.
( 2 ) Use DIP switches 1 through 5 to select the desired zone
output (see Table 1).
( 3 ) Click the MCR-308 tamper switch 1 or 2 or 3 or 4 times to
select the desired sub-zone (see Para. 3.4). Each click
advances to the next sub-zone. The status of the selected
sub-zone location will be shown by the red LED:
Status
Red LED Response
Location is free
LED Flashes
Location already contains an ID
LED Lights steadily
To clear a “busy” location, refer to Para. 3.7.
( 4 ) If the sub-zone location is free, initiate a transmission from
the transmitter you wish to enroll in the selected sub zone.
The red LED and the buzzer can respond as follows:
Red LED & Buzzer Response
Significance
Red LED: lights steadily;
Buzzer: “victory melody” (
)
Transmitter ID enrolled
Red LED: lights steadily;
Buzzer: “victory melody” (
)
twice
Transmitter ID enrolled
again (the same ID is
already saved in
another location)
Red LED: continues to flash;
Buzzer: remains silent
Transmitter ID not
enrolled
Note: You can not enroll a transmitter in a busy location.
However, if you try to enroll a transmitter in a busy location,
and the same ID is already enrolled in another location, the
buzzer will sound a long beep.
( 5 ) Repeat Steps 2 through 4 above for all the remaining
transmitters.
(
6
) When done, quit the LEARN mode by setting SW-8 to OFF.
Notes: 1. If the transmitter used is a wireless detector,
remove its battery to prevent accidental transmissions at a
later stage of the learning session
.
2. If you leave SW-8 in the ON position and no further
learning activity takes place for 5 minutes, the LEARN mode
will be automatically abandoned.
C. Memory Content Verification
To check whether a specific transmitter’s ID is programmed in a
certain zone, select the zone output and then the sub-zone in
question and initiate a transmission. If the saved and transmitted
IDs match, the buzzer will sound the victory melody (
).
If there is no match but the same ID is already enrolled in another
sub-zone location, the buzzer will sound a long beep. If the ID is
not recognized by the MCR-308, the buzzer will remain silent.
/HDUQLQJ([SDQGHU,'V
It is necessary to “teach” the MCR-308 which expander is related
to which group of zone outputs. The expander’s specific ID must
therefore be programmed into special expander locations in the
MCR-308 memory.
A. Preparations
(1)
Connect the expander (or expanders) to the expansion bus.
(2)
Remove the MCR-308 cover. The buzzer will beep once
upon release of the tamper switch.
B. Expander Learning Procedure
( 1 ) Set DIP switch SW-8 to ON (LEARN mode). The yellow
LED will flash at a constant rate throughout the learn period.
( 2 ) Use DIP switches 1 through 5 to select the desired expander
memory location as shown in Table 2 below:
Table 2. Expander Location Selection Chart
Expander
DIP Switches
Related Zone
Module
1
2
3
4
5
Outputs
1
st
ON
—
ON ON ON Zones 5 - 12
2
nd
—
ON ON ON ON Zones 13 - 20
3
rd
ON ON ON ON ON Zones 21 - 28
(3)
Click the MCR-308 tamper switch once. The status of the
selected expander memory location will be shown by the red
LED:
Status
Red LED Response
Location is free
LED Flashes
Location already contains an ID
LED Lights steadily
To clear a “busy” location, refer to Para. 3.7 below.
(4)
Click the expander’s tamper switch once. The red LED and
the buzzer will respond as follows:
Red LED & Buzzer Response
Significance
Red LED: lights steadily;
Buzzer: “victory melody” (
)
Expander ID enrolled
Red LED: flashes at a constant rate
Buzzer: remains silent
Expander ID not
enrolled
Note: If not enrolled, check the connections to the bus.
(5)
Repeat steps 2 and 3 above for all other expanders. When
done, quit the LEARN mode by setting SW-8 to OFF.
C. Expander ID Verification
To check whether a specific expander’s ID is properly program-
med, use DIP switches 1 through 5 to select the expander
location in question (see Table 2 above). Click the expander’s
tamper switch once to send its ID to the MCR-308. If the
programmed and transmitted IDs match, the buzzer will sound
the victory melody (
).
&OHDULQJ 6SHFLILF 7UDQVPLWWHU RU
([SDQGHU,'V
A. Set DIP switch SW-8 to ON (LEARN mode). The yellow LED
will flash at a constant rate throughout the learn period.
B. Use DIP switches 1- 5 to select the desired zone output (see
Table 1) or the expander module location (see Table 2).
Note: If you are clearing a transmitter ID, click the MCR-308
tamper switch 1 or 2 or 3 or 4 times to select the desired sub
zone location (see Para. 3.4). If you are about to clear an
expander’s ID, click the MCR-308 tamper switch only once.
The status of the selected sub-zone location will be shown by
the red LED:
Status
Red LED Response
Sub-zone or expander location is free
LED Flashes
Sub-zone or expander location already
contains an ID
LED lights steadily
C. Mount a jumper across the two CLEAR pins on the MCR-308
circuit board and remove it immediately. The red LED and the
buzzer will respond as follows: