![Visonic KF-235PG2 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/visonic/kf-235pg2/kf-235pg2_user-manual_1032957002.webp)
2
D-303486 KF-235 PG2 User's Guide
Stop Beeps:
Pressing the AUX button will cause the control panel and other devices in the system (such as keyfobs,
keypads, sirens etc.) to stop beeping (for example during exit or entry delays).
Skip exit delay:
Pressing the AUX button will immediately stop the exit delay and cause the system to arm instant.
PGM:
Pressing the AUX button will activate the PGM output. The functions of the PGM output is configured at the
corresponding sections of the control panel’s Installer Guide (see “OUTPUTS” menu) and User Guide (see
“SCHEDULER ” menu).
Arm instant:
Pressing the AUX button while the exit delay is in progress will cause the system to arm “instant” - the
entry delay is canceled.
* Applicable only to control panels that support the voice option.
•
3
3
3
3.
.
.
. USING THE KEYFOB
USING THE KEYFOB
USING THE KEYFOB
USING THE KEYFOB
3.1 Keyfob Functionality
Step
Functions
User Actions
ARM/DISARM LED Indication
1
Arm AWAY
Blue LED above AWAY button lights
Arm HOME
Blue LED above HOME button lights
Disarm (OFF)
Blue LED above DISARM button lights
2
LATCHKEY
Blue LED above AWAY button lights
3
PANIC alarm
Press the
and
buttons
simultaneously (
≈
2 sec.)
-
4
AUX
According to the state of the alarm system, see section 2.2
3.2 Keyfob Response
When executing a command, the keyfob's Transmission LED blinks red once to indicate transmission of the command to the control panel. If
the operation is
successfully completed
, the green LED lights momentarily and a
"happy tune"
is heard. If the operation
fails or cannot
be completed
, for example, when the system is "not ready", the red LED lights steadily and a
"sad tune"
is heard. When executing a
command and there is a communication failure between the keyfob device and the control panel, the keyfob's Transmission LED remains off
and no tune is heard.
3.2.1 Primary LED and Buzzer Response to Keyfob Commands
Panel Response
Buzzer Indication
Transmission LED Indication
Success:
Operation is successfully completed
Happy (
success
) beep
Momentary GREEN
Fail:
Operation
failed
Sad (
failure
) beep
Momentary RED
No communication:
For example, control panel is out of range.
None
None
Keyfob low battery:
Note:
If transmission is still possible despite the battery condition,
the unit will send a low battery signal to the control panel.
Depends on the operation that
is performed
Blinks yellow 2 sec.
Trouble in system:
Depends on the operation that
is performed
Lights yellow 2 sec.
When forced arming (bypass zones) is performed, the keyfob buzzer “protests” by emitting a continuous tone during the exit delay for 5
seconds (for more details, see the PowerMaster Installer Guide, section 5.5.2).
3.2.2 Arming LED indication
When executing a command using the keyfob device, the status of the control panel is indicated by the status LEDs that light blue.
System State
ARM/DISARM LED Indication
Exit from DISARM to AWAY
AWAY lights
Exit from DISARM to HOME
HOME lights
Entry from HOME
DISARM blinks
Entry from AWAY
DISARM blinks
Exit from HOME TO AWAY
AWAY lights
Exit from AWAY TO HOME
HOME lights
Installer mode, Sync mode or when the system is otherwise reachable but
unavailable
AWAY, HOME, DISARM all blink twice, wait, then blink twice
again