Visonic KF-235 PG2 Скачать руководство пользователя страница 2

D-303486 KF-235 PG2 User's Guide / Guía del usuario / Guia do utilizador 

Step 

Functions 

User Actions 

ARM/DISARM LED Indication 

Disarm (OFF) 

 

Blue LED above DISARM button lights 

 

2

 

LATCHKEY

 

 

Blue LED above AWAY button lights 

 

3

 

PANIC alarm*

 

Press the 

 and 

 buttons simultaneously (

 2 sec.) 

-

 

4

 

AUX

 

 

According to the state of the alarm system, see section 2.2 

“ For UL Listed product, “PANIC” is for Ancillary Use only. 

3.2 Keyfob Response 

When  executing  a  command,  the  keyfob's  Transmission  LED  blinks  red  once  to  indicate  transmission  of  the  command  to  the  control  panel.  If  the 

operation  is 

successfully  completed

,  the  green  LED  lights  momentarily  and  a 

"happy  tune"

  is  heard.  If  the  operation 

fails  or  cannot  be 

completed

, for example, when the system is "not ready", the red LED lights steadily and a 

"sad tune"

 is heard. When executing a command and 

there is a communication failure between the keyfob device and the control panel, the keyfob's Transmission LED remains off and no tune is heard. 

3.2.1 Primary LED and Buzzer Response to Keyfob Commands 

Panel Response 

Buzzer Indication 

Transmission LED Indication 

Success:

 Operation is successfully completed 

 

Happy (

success

) beep

 

Momentary GREEN

 

Fail:

 Operation 

failed 

 

 

Sad (

failure

) beep 

Momentary RED

 

No communication:

  For example, control panel is out of range.

 

None

 

None 

Keyfob low battery: 

Note: 

If transmission is still possible despite the battery condition, 

the unit will send a low battery signal to the control panel.

 

Depends on the operation that is performed

 

Blinks yellow 2 sec. 

Trouble in system:

 

Depends on the operation that is performed

 

Lights yellow 2 sec. 

When forced arming (bypass zones) is performed, the keyfob buzzer “protests” by emitting a continuous tone during the exit delay for 5 seconds (for 

more details, see the PowerMaster Installer Guide, section 5.5.2). 

3.2.2 Arming LED indication 

When executing a command using the keyfob device, the status of the control panel is indicated by the status LEDs that light blue. 

System State 

ARM/DISARM LED Indication 

Exit from DISARM to AWAY

 

AWAY lights

 

Exit from DISARM to HOME

 

HOME lights

 

Entry from HOME

 

DISARM blinks

 

Entry from AWAY

 

DISARM blinks

 

Exit from HOME TO AWAY 

 

AWAY lights

 

Exit from AWAY TO HOME 

 

HOME lights

 

Installer mode, Sync mode or when the system is otherwise reachable but unavailable

 

AWAY, HOME, DISARM all blink twice, wait, then blink twice again  

4. MAINTENANCE 

4.1 Replacing the Battery 

When the keyfob device stops operating due to low battery and until the time the battery is completely depleted, all LEDs will light blue.

 

A replacement 3V battery, VARTA CR-2032, is available from hardware and electrical supply stores. Replace the battery as shown in Figure 2. 

Caution!

 Battery may explode if replaced by incorrect type or if mistreated. Do not recharge, disassemble, or dispose of the battery in fire.

 

4.2 Cleaning 

Clean the keyfob only with a soft cloth or sponge moistened lightly with a mixture of water and mild detergent, and wipe it dry immediately. 

The use of abrasives of any kind is strictly forbidden. Also never use solvents such as kerosene, acetone or thinner.

 

4.3 Periodic Test 

Wireless equipment should be tested regularly to determine whether there are sources of interference and to protect against faults. 
Refer to the PowerMaster Installer Guide, Chapter 6 Periodic Test, for instructions on how to conduct a periodic test. 

5. TROUBLESHOOTING 

Problem  

Diagnosis 

Proposed actions 

Keyfob does not enroll 

1. Keyfob was pre-enrolled

 

1. Enroll the keyfob again in the vicinity of the control panel. 

 

2. The wrong ID number was 

entered

 

2. Reenter the ID number

 

3. No free location

 

3. If the maximum number of keyfobs has already been enrolled the alarm system 

will not allow enrolling any more keyfobs.

 

4. Unknown device

 

4. Make sure the frequency used for the device is the same as the control panel 

frequency.

 

Keyfob LED does not light when 

button is pressed 

Low battery condition

 

Replace the battery 

 

 

CAUTION!

 

Wireless control panels may be blocked by radio signals occurring on or near their operating frequencies

.

 

 

Содержание KF-235 PG2

Страница 1: ...nabled in the panel Enter PARTITIONS See Note 2 Assign partitions by pressing the and buttons Select Device Settings and see below to configure the AUX button means scroll and select 2 2 Configuring t...

Страница 2: ...indicated by the status LEDs that light blue System State ARM DISARM LED Indication Exit from DISARM to AWAY AWAY lights Exit from DISARM to HOME HOME lights Entry from HOME DISARM blinks Entry from...

Страница 3: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...

Страница 4: ...ntras el retardo de salida est en progreso har que el sistema se arme instant neamente el retardo de entrada es cancelado S lo se aplica a los paneles de control que admiten la opci n de voz 3 USANDO...

Страница 5: ...alrma no permitir memorizar m s mandos 4 Dispositivo desconocido 4 Aseg rese de que la frecuencia usada para el dispositivo es la misma que la frecuencia del panel de control El LED del mando no se il...

Страница 6: ...orrer e seleccionar Notas 1 Se o dispositivo j estiver registado pode configurar os par metros do dispositivo e atribuir parti es atrav s da op o Modif Dispos veja o Passo 2 2 PARTI ES s ser vis vel s...

Страница 7: ...r de DIST para DIST INIC acende se Modo do instalador modo de sincroniza o ou quando de outro modo o sistema pode ser contactado mas est indispon vel DIST INIC DESARM piscam todos duas vezes pausa e d...

Страница 8: ...M CHAVE ARM B IN CIO ARM C DESARMAR D AUX E LED de transmiss o F LED de estado Fig 1 External View Vista Externa Vista Externa Fig 2 Battery Replacement Reemplazo de la bater a Substitui o da bateria...

Отзывы: