NEXT PG2, NEXT-K9 PG2
8
D-302758
3. ENROLLMENT
Refer to the PowerMaster-10 Installer Guide for the device enrollment procedure.
4. MODIFY DEVICE SETTINGS
This section describes how to configure the parameters of the PIR detector from the PowerMaster-10 control
panel.
To Modify the PIR Detector Device Settings
Refer to the PowerMaster-10 Installer Guide and perform the procedure for Adding A Wireless Device (section
4.5.2), or, Modifying a Device (section 4.5.5). Then continue below to modify the device settings.
1.
Here you determine whether or not the alarm LED indication will be
activated.
2.
3.
or
Select between "
LED ON
" and "
LED OFF
".
4.
5.
Here you determine whether an alarm will be activated upon continued
motion (low sensitivity) or upon a single alarm event (high sensitivity).
6.
7.
or
Select between "
LOW sensitive
" and "
HIGH sensitive
".
8.
9.
Here you set the activity time during disarm.
10.
11.
or
Select between "
NOT Active
", "
YES – no delay
", "
YES + 5s delay
",
"
YES + 15s delay
", "
YES + 30s delay
", "
YES + 1m delay
", "
YES + 2m
delay
", "
YES + 5m delay
", "
YES + 10m delay
", "
YES + 20m delay
" and
"
YES + 60m delay
".
12.
When exiting "
ZONES / DEVICES
" menu, the PowerMaster-10 system
displays the number of devices that need to be updated, as follows: DEV
UPDATING NNN.
For detailed instructions on Adding Devices, Deleting Devices, Replacing
Devices and Defining Defaults see the PowerMaster-10 Installer Guide.
Alarm LED
DISARM Activity
NOT Active
DISARM Activity
Event Counter
LED Sensitive
Event Counter
Alarm LED
DEV SETTINGS
LED ON