Mounting the Device

For mounting the device with a bracket, refer to the BR-1, BR-2 or BR-3 Installation Instructions. Note that you can also mount the device without a BR
bracket.

1. Fasten the breakaway segment to the wall.

A. Mounting holes

B. Break-away base segment

C. Fastening screw

Figure 7. GB-502 PG2 Internal View

Attention!

The GB-502 PG2 has a back tamper switch under the PCB. As long as the PCB is seated firmly within the base, the switch is pressed

against a special break-away base segment that is loosely connected to the base. Be sure to fasten, using screw C, the break-away segment to
the wall. If the detector unit is forcibly removed from the wall, this segment will break away from the base, causing the tamper switch to open!

2. Put back the cover on the base and secure with screw.

Figure 8. Closing the Cover

Enrollment of the Device

Refer to the PowerMaster panel's Installer Guide and follow this procedure under the "02:ZONES/DEVICES" option of the Installer Menu.

1. Enter the Installer menu and select “02:ZONES/DEVICES”.

02.ZONES/DEVICES

ð

2. Select "ADD NEW DEVICE". Option.

ADD NEW DEVICES

ð

3. Enroll the device or Enter the device ID.

ENROLL NOW or
ENTR ID:XXX-XXXX

ð

4. Select the desired Zone Number.

Z04:Glass Break
ID No. 160-XXXX

ð

(with panels PowerG V.19.1 & lower)

ID No. 161-XXXX

ð

(with panels PowerG V.19.2 & higher)

5. Configure Location & Zone Type Parameters.

Z06.LOCATION
Z06.ZONE TYPE

ð

means scroll

ww

and select

OK

.

Содержание GB-502 PG2

Страница 1: ...mni directional providing fullcoverage Coverage is measured from the sensor to the point on the glass farthest from the sensor The sensor can be mounted as close as 1 5 m 5 ft from the glass Figure 2 Typical Range Measurement When mounted on opposite walls on adjoining walls or on the ceiling the range is 7 6 m 25 ft for plate tempered laminated wired coated and sealed insulating glass The coverag...

Страница 2: ...ur loop applications where the sensor is armed allday and allnight the false alarm prevention technology willbe pushed to its limit Some sounds can duplicate the glass break pattern the acoustic sensor detects Installthe GB 502 PG2 on a perimeter loop which is armed whenever the door and window contacts are armed NOTE GB 502 PG2 shallbe installed in accordance with the Standard for Installation an...

Страница 3: ... reflection off the opposite wall Inserting the Battery 1 Press in the snap and separate the cover from the base A Snap Figure 4 Opening the Unit 2 Get to know the items indicated in Figure 5 they are allrelevant to the steps you willhave to take in the course of installation A Battery B Enroll button C Tamper contact Figure 5 Inside View 3 Insert the battery into the battery clips Observe Polarit...

Страница 4: ...egment to the wall Ifthe detector unit is forcibly removed from the wall this segment willbreak away from the base causing the tamper switch to open 2 Put back the cover on the base and secure with screw Figure 8 Closing the Cover Enrollment of the Device Refer to the PowerMaster panel s Installer Guide and follow this procedure under the 02 ZONES DEVICES option of the Installer Menu 1 Enter the I...

Страница 5: ...lex signaland simulate a glass breaking sound by using one of the following methods l Simulator in manualmode Hold the simulator close to the protected glass Thump the glass and immediately start the simulator manually to create the sound of break ing glass Examples of such simulators are AFT 100 or 5709C l Simulator with automatic activation Hold the simulator close to the protected glass Thump t...

Страница 6: ...0 2 sec Green 0 2 sec Red 30 sec OFF Self test failure Normalmode Compliance With Standards The GB 502 PG2 complies with the following standards Europe EN 300220 EN 301489 EN50130 4 EN60950 EN50130 5 EN 50131 2 7 1 EN 50131 1 Grade 2 Class II This device complies with the essentialrequirements and provisions of Directive 1999 5 ECof the European Parliament and of the Councilof 9 March 1999 on radi...

Страница 7: ... MHz Operating Temperature 10 Cto 50 C 14 F to 120 F indoors Storage Temperature 20 Cto 60 C 4 F to 140 F Humidity 5 to 95 with no condensation ACOUSTIC SENSOR Microphone Omni directional Maximum Detection Range 7 6 m 25 ft if glass size is minimum 40 x 40 cm 15 x 15 6 m 20 ft if glass size is 30 x 30 cm 12 x 12 to 40 x 40 cm 15 x 15 Glass Types Plate tempered wired laminated covered and sealed in...

Страница 8: ...anty willbe credited or replaced at the Seller s option THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS OR LIABILITIES WHETHER WRITTEN ORAL EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF T...

Страница 9: ... any images photographs and text incorporated into the Software the accompanying printed materials and any copies of the Software are owned by Tyco and or its suppliers The Software is licensed not sold Allrights not expressly granted under this EULA are reserved by Tyco and its suppliers 2 GRANT OF LICENSE This EULA grants you the following rights on a non exclusive basis a General This EULA perm...

Страница 10: ...ing your Tyco representative g Trademarks This EULA does not grant you any rights in connection with any trademarks or service marks of Tyco its affiliates or its suppliers h Rental You may not sublicense rent lease or lend the Software You may not make it available to others or post it on a server or web site or oth erwise distribute it i Software Keys The hardware software key where applicable i...

Страница 11: ... RECORDS OR DATA OR LIABILITIES RELATED TO A VIOLATION OF AN INDIVIDUAL S PRIVACY RIGHTS OR III INDIRECT INCIDENTAL SPECIAL CONSEQUENTIAL PUNITIVE RELIANCE OR COVER DAMAGES INCLUDING WITHOUT LIMITATION LOSS OF PROFITS BUSINESS INTERRUPTION LOSS OF DATA OR BUSINESS INFORMATION AND LOST SAVINGS IN EACH CASE EVEN IF TYCO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES YOU ARE SOLELY RESPONSIBLE A...

Отзывы: