2.4. Setting the Coverage Range
The CLIP PG2 can be programmed to select one of three ranges,
according to the type of installation, for the curtain beams (see
Figure 15
and
Configuring the Detector Parameters
).
A.
Minimum range
B.
Medium range
C.
Maximum range
Figure 15. Range Setting Diagram
2.5. Walk Testing
A.
Mount the cover and tighten the screw. Wait for the detector to stabilize (the LED stops flashing approx. 1 minute after the cover is closed).
B.
Walk slowly across the far end of the curtain pattern in the opposite direction. The LED indicator lights for approximately 3 seconds whenever you
enter or exit a curtain beam.
Important!
Important: Perform walk test at least once a week to assure proper function of the detector.
Note:
After closing the cover the detector enters a 15 minute walk test mode. In this mode the LED flashes each time a detection occurs,
regardless of the LED jumper settings, and the detector transmits on the occurrence of each detection event.
2.6. Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A general
description of the procedure is provided in the following flow chart.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Enter the Installer menu
and select
"02:ZONES/DEVICES"
Select "ADD NEW
DEVICE" Option. See
Note [1]
Enroll the device or
Enter the device ID
Select the desired
Zone Number
Configure Location, Zone
Type & Chime Parameters
Configur
e the
Detector
02.ZONES/DEVICES
ð
ADD NEW DEVICES
6
MODIFY DEVICES
ð
ENROLL NOW
or
ENTR ID:XXX-XXXX
ð
Z03:Motion Sens
ID No. 122-XXXX
ð
Z03:LOCATION
Z03.ZONE TYPE
Z03:SET CHIME
Z03:DEV SETTINGS
ð
ð
means scroll
ww
and select
OK
.
See
Note [2]
Notes:
1.
If the detector is already enrolled you can configure the keyfob parameters via the “
Modify Devices
” option – see Step 2.
2.
Select the "
Device Settings
" option and refer to
Configuring the Detector Parameters
to configure the detector parameters.
2.7. Configuring the Detector Parameters
Enter the
DEVICE SETTINGS
menu and follow the configuration instructions for the CLIP PG2 curtain detector as described in the following table.
Option
Configuration Instructions
Alarm LED
Determine whether or not to activate the alarm LED indication.
Optional settings: LED ON (default) and LED OFF.
PIR RANGE
Select one of the three ranges, according to the type of installation, for the curtain beams. Select
"Maximum" for a range of 6 m, select "Medium" for a range of 4 m, or select "Minimum" for a range of
2 m.
Optional settings: Maximum (default), Medium and Minimum.
DISARM Activity
Define whether or not to set the activity time during disarm.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s
delay, YES + 1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and
YES + 60m delay.