1. INTRODUCTION

The CLIP PG2 is a small and elegant wireless curtain-pattern PIR detector for indoor use and designed for easy installation.

Modern technology is used to include 3 different detectors in a single case, each programmable for optimized performance at the specific mounting
location. This results in better catch performance and virtually no false alarms.

The superiority in performance of this detector is achieved by applying an improved version of the patented

True Motion Recognition™

(TMR)

algorithm. This advanced motion analysis method allows the CLIP PG2 to distinguish between the true motion of the human body and any other
disturbances that cause

false alarms

.

The CLIP PG2 includes the following features:

l

For use with all PowerMaster® control panels (version 13 and higher).

l

2-way PowerG protocol communication

l

Very low current consumption

l

Microprocessor-controlled temperature compensation

l

Sealed chamber protects the optical system

l

Front cover tamper switch

l

Optional back tamper switch

l

White light protection

l

Elegantly styled, sturdy case

l

RF Link quality indication

Detailed coverage patterns and mounting alternatives are illustrated in

Figures 2 through 6

.

Note:

The pet immunity feature was not evaluated by UL.

Figure 1. CLIP PG2 General View

Figure 2. Wall-Mount Curtain

Figure 3. Ceiling-Mount Curtain

Figure 4. Overhead Curtain

Figure 5. Curtain / Pet Alley

Figure 6. CLIP PG2 on Internal Doorframe

A.

This side up

B.

6 m (20 ft) max. distance

C.

1 m (3.3 ft) max. width

D.

0.5 m (1.65 ft) max. width

E.

3.6 m (12 ft) max. distance

F.

Detection curtain

G.

Option A

H.

Option B

CLIP PG2

PowerG Wireless, Curtain, PIR Motion Detector

Installation Instructions

Содержание CLIP PG2

Страница 1: ...ng features l For use with all PowerMaster control panels version 13 and higher l 2 way PowerG protocol communication l Very low current consumption l Microprocessor controlled temperature compensation l Sealed chamber protects the optical system l Front cover tamper switch l Optional back tamper switch l White light protection l Elegantly styled sturdy case l RF Link quality indication Detailed c...

Страница 2: ...ns of burglar and Holdup Alarm Systems 2 2 Regular Mounting Note Mount the detector so that its orientation is perpendicular to the expected intrusion path A Enroll button B Front tamper switch C RF Module D Sensor E LEDs F Back tamper switch optional G 3 Volt Lithium battery A Back tamper switch A back tamper alert is activated when the base is detached from the wall Figure 7 Internal View Figure...

Страница 3: ... used for EN installations Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to manufacturer s instructions 2 3 Bracket Mounting Note Mount the detector so that its orientation is perpendicular to the expected intrusion path Note When mounting using the bracket the back tamper becomes inoperative 1 Drill two 7 mm 1 4 holes at the marked locatio...

Страница 4: ... Securing Locking Plate to Base 1 Position the PCB correctly in the base 2 Insert the screw to secure the cover with the base Figure 13 Mounting Cover to Base A Window Note The CLIP PG2 can be mounted on either side of a window Figure 14 Mounting on Both Sides of a Window D 303370 CLIP PG2 Installation Instructions 4 ...

Страница 5: ...See Note 1 Enroll the device or Enter the device ID Select the desired Zone Number Configure Location Zone Type Chime Parameters Configur e the Detector 02 ZONES DEVICES ð ADD NEW DEVICES 6 MODIFY DEVICES ð ENROLL NOW or ENTR ID XXX XXXX ð Z03 Motion Sens ID No 122 XXXX ð Z03 LOCATION Z03 ZONE TYPE Z03 SET CHIME Z03 DEV SETTINGS ð ðmeans scroll wwand select OK See Note 2 Notes 1 If the detector is...

Страница 6: ...lares that the radio equipment type CLIP PG2 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address http www visonic com download center EN 50131 1 Security Grade According to EN 50131 1 2006 and A1 2009 this equipment can be applied in installed systems up to and including Security Grade 2 EN 50131 1 Environmenta...

Страница 7: ...thium battery type CR 123A or equivalent Notes 1 Use only the above battery type 2 For UL installations use Gold Peak GP or Panasonic CR123A only Nominal Battery Capacity 1450 mA h Low Battery Threshold 2 45 V Battery Life for typical use 7 years FUNCTIONAL Visual indications Red LED lights for about 2 seconds upon motion detection in the walk test mode and for about 0 2 sec for tamper messages Re...

Страница 8: ...ect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at the Seller s option THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS OR LIABILITIES WHETHER WRITTEN ORAL EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A P...

Страница 9: ...by their own warranty if any The Manufacturer shall not be liable for any damage or loss whatsoever whether directly indirectly incidentally consequentially or otherwise caused by the malfunction of the Product due to products accessories or attachments of others including batteries used in conjunction with the Products This Warranty is exclusive to the original Purchaser and is not assignable Thi...

Отзывы: