Visonic AMBER SELECT Скачать руководство пользователя страница 4

D-301438 AMBER SELECT / AMBER SELECT

X

 USER’S GUIDE 

Special Functions:

 

 

-   Calling for help by using an emergency pendant 

transmitter 

-  Speakerphone (hands-free) when communicating 

with Monitoring Center or when answering an 
incoming call by pressing the pendant 

-  The system supports up to 29 users (pendant 

transmitters and smoke detectors). 

   -   Two-way voice communication 

-  Computer control and data download/upload 
-   Remote control by telephone 

-   Remote diagnostic and event log 
-   Visual and audible announcements 

Physical Properties 

Operating Temperature:

 32

F to 104

F (0

C to 40

C) 

 

Storage Temperature: 

-4

F to 140

F (-20

C to 60

C) 

Size:

 9-13/16 x 7-1/4 x 2-5/16 in. (248 x 185 x 55 mm). 

Weight: 

3 lb (1.35 kg)

 

Color:

 Off-white 

Note:

 The product supports all standard monitoring 

center receivers such as Osborne-Hoffman. 

SYSTEM SETUP 

To set up your system, follow the steps below.  

Step 1 

Select Unit Location 

If possible, select a central location in your home for the 
Unit. This location should be in the area where you 
spend most of your time. The location should also 
enable an optimal signal reception for pendants and 
smoke detectors.  
The Unit can be placed on a table, desk, or counter. It 
also can be mounted on a wall. 
Make sure that the location you have selected is near 
an electrical outlet and a phone jack. 

Step 2 

Connect the Unit to your 

Telephone Line (Figures 3a and 

3b)

*

 

The AMBER SELECT / AMBER SELECT

X

 

communicates with your Monitoring Center through 
your telephone line. 

1.

  Locate the phone jack on your wall where you want 

to connect your AMBER SELECT / AMBER 
SELECT

X

. If a phone is already plugged into that 

jack, unplug it and connect it to the "PHONE" 
connector on the back of the AMBER SELECT / 
AMBER SELECT

X

. Your telephone will still function 

normally. 

2.

 Connect the wide end (RJ-45) of the phone cord to 

the "Wall Jack" on your AMBER SELECT / AMBER 
SELECT

X

. Plug the narrow end (RJ-11) of that 

phone cord into the phone jack on your wall. The 
AMBER SELECT / AMBER SELECT

X

 is now 

connected to your telephone line.  

Note: 

Be aware of other phone line services such as 

DSL. If DSL service is present on the phone line, you 
must install a filter. See Figures 3a and 3b for proper 
installation. 

                                                 

*

 

For advanced phone connections see Customer Information.

 

POWER CORD

SAFETY CATCH

TURN THE SAFETY CATCH

SCREW IN THE DIRECTION

SHOWN

Phone Line

RS232

AUX

(optional)

 

Figure 3a 

12 VAC 1 A

120 VAC

120 mA AC

Voltage output:

 9.6 V

Max. current output:

 1 A

Max. charge currents

       

Fast charge:

 160 mA

       

Trickle charge: 

90 mA

Battery capacity: 

1.8 Ah

Battery

Pack

 

Figure 3b

 – Installation: Power, Telephone and Tel. line 

battery Connection

 

Note: 

It is recommended that the AC power input, the 

RS-232, and the telephone be interconnected within the 

same room. 

Step 3 
Program the panel: 

Local setup

  

1.

  Install the HHCPC software on your PC.  

2.

  Enter all the desired programming information into 

the HHCPC. Connect one end of the special cable 
(supplied by Visonic) to one of the computer's COM 
ports and the other end to the AMBER SELECT / 
AMBER SELECT

X

 unit. 

Содержание AMBER SELECT

Страница 1: ...D 301438 AMBER SELECT AMBER SELECTX USER S GUIDE 1 AMBER SELECT AMBER SELECTX Wireless Emergency Response System User s Guide ...

Страница 2: ...120VAC to 12VAC transformer type OH 48109AT Input 120VAC 60 Hz Output 12VAC 1000 mA Pendant transmitters supplied with necklace Additional Accessories Optional Battery operated smoke detector MCT 425 Waterproof arm disarm security activation pendant transmitter MCT 201 WP Fully supervised indoor PowerCode gas detectors MCT 440 MCT 441 and carbon monoxide gas detector MCT 442 Fully supervised indoo...

Страница 3: ...y with 3 LED indicators UL Compliant AMBER SELECTX only Battery Pack NI MH 9 6 V 1 8 Ah type GP 0 9912 G Supply Voltage 12 VAC 1 A via 120VAC 60Hz transformer Non UL Compliant AMBER SELECTX only Battery Pack NI MH 7 2 V 1 3 Ah type 103 301179 Supply Voltage 9 VAC 750 mA Compliance Complies with FCC part 68 and part 15 and UL 1637 Home Health Care Signaling Equipment MCT 425 is designed to comply w...

Страница 4: ...nicates with your Monitoring Center through your telephone line 1 Locate the phone jack on your wall where you want to connect your AMBER SELECT AMBER SELECTX If a phone is already plugged into that jack unplug it and connect it to the PHONE connector on the back of the AMBER SELECT AMBER SELECTX Your telephone will still function normally 2 Connect the wide end RJ 45 of the phone cord to the Wall...

Страница 5: ...ou complete the steps above your AMBER SELECT AMBER SELECTX will automatically call your Central Station provided that your unit was programmed to report to Central Station and not to private telephones The central station operator will begin a two way voice session Once this feature has been tested the operator must disconnect by pressing DTMF 99 Note Certain remote areas of your residence may li...

Страница 6: ...1WP Direct Link Speed Dial The AMBER SELECT AMBER SELECTX includes 3 buttons for unique direct link Using your Pendant Transmitter The pendant transmitter can be used to initiate an emergency call and also to answer incoming calls Pendant Activation Your pendant transmitter lets you signal to the AMBER SELECT AMBER SELECTX from anywhere in your home when you need emergency assistance You should we...

Страница 7: ...iates two way communication To return the status to HOME mode hold down the CHECK button for 5 seconds The unit s speaker will announce and display AMBER SELECT only HOME REMINDERS ON The status LED will turn on System status conditions are indicated by the yellow LED Yellow LED Definition Off Away mode On Home mode Flashes Active reminder Clock Adjustment Announcement To Set the Clock AMBER SELEC...

Страница 8: ...ay AMBER SELECT only shows CALL WAS PRESSED you do not need to press the button again A representative will begin speaking to you shortly Remote two way voice communication access You can access the AMBER SELECT AMBER SELECTX system from a remote telephone for 2 way voice communication as follows 1 Dial the AMBER SELECT AMBER SELECTX tel No 2 Wait for 2 4 rings then hang up 3 Wait 12 30 sec 4 Redi...

Страница 9: ...ion Tel 1 and or Central Station Tel 2 and a Staff escalation event is recorded in the event log Warden Mode Warden mode enables the HHCPC software program to divide the reporting of events between the Central Station and private telephones in the following order 1st and 2nd private telephone numbers the first private telephone number is dialed then the second private telephone number is dialed an...

Страница 10: ...heduled time the unit will announce and display AMBER SELECT only Please Test Your Pendant The panel will also display AMBER SELECT only Press Your Pendant along with the pendants name You must then press the pendant transmitter whereby the unit will announce and display AMBER SELECT only Test Complete MAINTAINING YOUR SYSTEM The transmitter may get dirty if touched with greasy fingers Clean it on...

Страница 11: ...ct your Monitoring Center The display AMBER SELECT only shows AMBER SELECT AMBER SELECTX LOW BATTERY The AMBER SELECT AMBER SELECTX s batteries are low The AMBER SELECT AMBER SELECTX informs your Monitoring Center Batteries will be recharged when AC power is restored If after 48 hours of charging the AMBER SELECT still displays LOW BATTERY the batteries should be replaced The display AMBER SELECT ...

Страница 12: ... disabilities make sure that someone is assigned to assist them in the fire drill and in the event of a real life emergency Agree on an outside meeting place where everyone can meet once safely out of the house premises Remember to get out of the house first and then to call for help Never go back inside the house until authorized by the fire department Ensure that all members of the family memori...

Страница 13: ...e to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected...

Страница 14: ...th Part 68 rules and requirements adopted by ACTA and properly installed RJ31X connector See Installation Instructions for details 3 If the AMBER SELECT AMBER SELECTX causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required If advance notice is not practical you will be notified as soon as possible Also you will ...

Страница 15: ...twork Service Provider s Facilities Telephone Line Network Demarcation Point Telephone Answering System Telephone Unused RJ 11 Jack Telephone Computer Unused RJ 11 Jack Alarm Dialing Equipment Customer Premises Equipment and Wiring Fax Machine RJ 31X JACK ...

Страница 16: ...l be fixed as liquidated damages and not as a penalty and shall be the complete and exclusive remedy against the Manufacturer When accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may ...

Отзывы: