background image

 

 

Vislink Technologies, Inc., Waterside House, Earls Colne Business Park, Colchester, Essex, CO6 2NS, UK 

Telephone: +44 (0)1442 431300 

 Facsimile: +44 (0) 1494 775356 

 Email: [email protected] 

 Website: www.vislink.com 

 

Company Registered in England & Wales no. 10523708 

 VAT registration no. GB 260 012 169 

Registered Office: Waterside House, Earls Colne Business Park, Colchester, Essex, CO6 2NS, UK 

 

 

 

 

 

IRD6200 Satellite IRD  

User Manual 

Содержание IRD6200

Страница 1: ...hone 44 0 1442 431300 Facsimile 44 0 1494 775356 Email sales vislink com Website www vislink com Company Registered in England Wales no 10523708 VAT registration no GB 260 012 169 Registered Office Waterside House Earls Colne Business Park Colchester Essex CO6 2NS UK IRD6200 Satellite IRD User Manual ...

Страница 2: ...ed by Vislink Technologies Inc Conventions NOTE Notes are used to convey additional information CAUTION Cautions highlight potential equipment damage WARNING Warnings highlight potential personal danger or death Ensure you read and understand all warnings before attempting to carry out any work on any equipment attached or related to the equipment in use The danger is real and not understanding th...

Страница 3: ...Issue No 1 Page iii Ref IRD6 ASUM 700X Copyright 2019 Vislink Technologies Inc Document History Version Date Modification FW Ver 1 24 10 19 First Issue ...

Страница 4: ...io Decode Standards 4 2 10 Physical 4 2 10 1 Size 4 2 10 2 Weight 4 2 10 3 Power 4 2 10 4 Environmental 4 2 11 Optional Licenses 5 2 12 Input Output Connections 5 2 12 1 Inputs and Outputs 5 2 13 Pinout Information 6 2 13 1 RF1 2 Inputs 6 2 13 2 ASI IN 6 2 13 3 Frame Lock Input 6 2 13 4 Video Outputs 6 2 13 5 ASI Output 6 2 13 6 Data 7 2 13 7 Audio 1 2 7 2 13 8 Ethernet Control 7 3 Controls 9 3 1 ...

Страница 5: ...nu 14 4 3 1 Presets 14 4 3 2 Control Interface 14 4 3 3 Defaults 14 4 3 4 Licenses 14 4 3 5 Time 15 4 4 Support Menu 15 4 4 1 Diagnostics 15 4 5 Menu Overview 15 4 6 Webserver Operation over RJ45 Port 15 4 6 1 How Do I Set Up a Basic Connection 15 4 6 2 Accessing the IRD6200 via Web Browser 16 4 6 3 Routing Page 16 5 Licenses and Upgrades 17 5 1 Licensing 17 5 2 Firmware Upgrades 17 ...

Страница 6: ... Inc Table of Figures Figure 2 1 Input Output Connections 5 Figure 3 1 IRD6200 Front Panel 9 Figure 4 1 Web Page Example 16 Table of Tables Table 4 1 Audio 12 Table 4 2 Presets Menu Overview 14 Table 4 3 Control Interface Menu Overview 14 Table 4 4 Defaults Menu Overview 14 ...

Страница 7: ...ety Information To ensure awareness of potential hazards all personnel concerned with the operation or maintenance of the equipment must study the information that follows together with local site regulations CAUTION We strongly recommended returning all RF equipment to Vislink for servicing WARNING GaAs BeO Hazard Certain components inside the equipment contain Gallium Arsenide and Beryllium Oxid...

Страница 8: ...ny of the supplied equipment as household waste The supplied equipment is not biodegradable in landfill sites For safe disposal of the supplied equipment take it to your local council authority environmental waste site For details contact your local authority recycling center NOTE In Europe dispose of all equipment in accordance with the European Environmental directive 1 3 Environmental CAUTION P...

Страница 9: ...10 bit HEVC HD dual decode DVBS2 Q 8PSK DVBS2 16 32APSK DVBS2X Q 8PSK 16APSK 2 1 Firmware Version See the Vislink ftp website for details of latest firmware revision ftp ftp vislink com 2 2 Demodulation DVB S QPSK DVB S2 QPSK 8PSK DVB S2X Up to 32APSK 2 3 Decoder Options HEVC H 265 dual decoder option AVC H 264 MPEG 2 2 4 Video Formats 480i 29 97 576i 25 720p 50 59 94 60 1080i 50 59 94 60 1080p 23...

Страница 10: ...annel interface on 15w D Type CTRL DATA 4 x 3G SDI SMPTE 424M UHD 1 x HD SDI SMPTE 424M HD 2 8 Video Decode Standards HEVC H 265 UHD HD MPEG 4 AVC H 264 HD MPEG 2 2 9 Audio Decode Standards Linear PCM MPEG 1 Layer I Layer II AAC 2 10 Physical CAUTION To avoid overheating keep all vents clear In particular ensure the front left and rear right side vents are clear to allow adequate airflow 2 10 1 Si...

Страница 11: ... HEVC HD dual decode DVBS2 Q 8PSK DVBS2 16 32APSK DVBS2X Q 8PSK 16APSK 2 12 Input Output Connections Figure 2 1 Input Output Connections 2 12 1 Inputs and Outputs Summary details in Section 2 13 2 x UHF input 950MHz to 2150MHz 1 x ASI input complies with ISO IEC 13818 2 188 burst byte mode 1 x Frame lock input Black Burst or Tri level 4 x Video outputs UHD or 1x HD 1 x confidence monitor output 1 ...

Страница 12: ...8 burst byte mode 2 13 3 Frame Lock Input 75Ω mini BNC chassis mounted socket Optional to genlock decoder output for both SD HD video SD Mode Composite Black and Burst input for timing reference HD Mode Supports HD tri level sync reference input NOTE Delay increases by up to 40ms 2 13 4 Video Outputs 75Ω mini BNC chassis mounted socket Output 1 4 Four 3G HDSDI for UHD SMPTE 292M 1 485Gbps One HDSD...

Страница 13: ... a major alarm 15W PIN Signal Description Remark 14 Status relay Relay contact opens on fault Internal link to swap NC NO 15 Status relay Relay contact opens on fault Internal link to swap NC NO 2 13 7 Audio 1 2 The audio channels one and two are not available 2 13 8 Ethernet Control Standard 10 100 Ethernet connection for control of the unit using Web Browser HTTP and Network Management SNMP If r...

Страница 14: ...IRD6200 IRD User Manual Introduction Issue No 1 Page 8 Ref IRD6 ASUM 700X Copyright 2019 Vislink Technologies Inc This page is intentionally unused ...

Страница 15: ... navigate around the menu tree The ENTER key initially selects an option or a choice Change the parameter value using the UP DOWN LEFT RIGHT arrow keys Pressing ENTER key commits the change or ESCAPE aborts the change The upper line in smaller font of the LCD shows the parameters available by means of a prompt Access to the next menu level or a summary of the status of the menu option Some menus d...

Страница 16: ...result in an Amber LED The ALARMS menu option lists the type of error Set the priority of each alarm from the web pages See Section 4 6 POWER Green Illuminates to indicate the unit has power Use the front panel USB port for software updates via a suitable USB stick For update information see the unit s firmware update notes available from the Vislink ftp site ftp ftp vislink com Vislink 20Products...

Страница 17: ...up screen press menu key to navigate to TUNER 2 Press ENTER and then select SETUP INPUTS Choices here are Input select Choose RF 1 or RF 2 The following parameters can be set for each RF input Frequency set the required receive frequency displayed in MHz If the LO frequency is zero then this is the direct L band frequency in the range 950 2150MHz Symbol Rate set the required symbol rate LNB 1 2 LO...

Страница 18: ...e transmitter UHD formats set the mode of the video outputs to either quad split 4 x 3G or 2SI NOTE When the unit is set to quad split output the delay is fixed Set the Monitor output to SDI or ASI With the monitor set to SDI with quad split output and decoding UHD formats the SDI monitor either displays individual selected quadrants or displays each quadrant in 15 second intervals Set the video o...

Страница 19: ...s tri level or composite sync to provide the timing reference NOTE Using ON external adds 40ms delay to the system internal or external ON internal references the video to an internal oscillator When ON the line pixel offsets are adjustable The line number is adjustable between 0 and 1124 For negative offsets use values between 0 and 540 for positive offsets use the formula 1124 minus the offset r...

Страница 20: ...n the unit s web page This helps to identify the unit in use when working with multiple units Ethernet Port Set the IP parameters for the Ethernet control port Status Pin The Status pin in the CC ALM connector see Section 2 13 8 is an open drain output that connects to Ground when active When active the default value is to active an Alarm You can choose whether it is active high or low It can also...

Страница 21: ...ork using a standard or crossover Ethernet cable 4 6 1 How Do I Set Up a Basic Connection To make individual IRD6200 configuration easier access the inbuilt menu system using the integrated webserver Use the following procedure to connect to the webserver over the RJ45 network port 1 Power up the unit and wait for the unit to fully boot 2 Connect the unit to a PC running a web browser either direc...

Страница 22: ...onfigured the IP ports and connected the RJ45 cable an LED illuminates on the RJ45 port to indicate a connection 4 6 2 Accessing the IRD6200 via Web Browser 1 From your chosen browser in the address bar enter the IP address for the unit The factory default address is http 192 168 000 90 2 After a short delay the menu displays on the webpage see Figure 4 1 3 Now make your required configuration cha...

Страница 23: ...Before ordering the license s you will need to provide the required ESN Electronic Serial Numbers and hardware serial numbers as requested from the webpage See Section 4 4 to locate electronic serial numbers Hardware serial numbers are located on the unit s chassis 5 2 Firmware Upgrades To upgrade the unit s firmware refer to the firmware release note for your unit Firmware update information is a...

Страница 24: ...IRD6200 IRD User Manual Licenses and Upgrades Issue No 1 Page 18 Ref IRD6 ASUM 700X Copyright 2019 Vislink Technologies Inc This page is intentionally unused ...

Отзывы: