![Vislink AJ-RC10 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/vislink/aj-rc10/aj-rc10_user-manual_1032720011.webp)
User Manual Focal Point
General Information
Issue No: M
Page: 3
Ref: FOCL-ASUM-8xxx
Copyright © 2017 Vislink plc
To be safe:
1.
Do not touch the radiating element when the unit is switched on.
2.
Operators should not operate any RF transmitter or power amplifier with any of its
covers removed or without appropriate antenna(s) fitted, nor should they allow
anyone else to do so.
3.
Operators should adhere to a minimum separation between the Operator and the
radiating element for the frequency range 435 – 490 MHz and the transmit power of
5W. Table 1-2 gives some recommendations.
Frequency (MHz) @
5W Transmit Power
Distance in mm
435
330
440
332
445
334
450
335
455
337
460
339
465
341
470
343
475
345
480
346
485
348
490
350
Table 1-2
Safe Working Distance
WARNING: Operators should maintain a safe working distance and ensure they do not
stand or walk in front of any antennas or allow anyone else to do so.
WARNING: Operators should not operate any RF transmitter or power amplifier with any of
its covers removed or applicable antennas fitted or allow anyone else to do so.
WARNING: DO NOT allow the antenna to come close to or touch the eyes, face or any
exposed body parts while the equipment is transmitting.
WARNING: DO NOT operate the equipment near electrical blasting caps or in an explosive
atmosphere.