background image

 

 

3.1.8 Application   

 

 

FTP server configuration means connecting to the server designated by customers by 

setting the FTP server parameters. For example, photos captured by MDVR can be configured to 

upload to the FTP server. The user can upload photos to a corresponding server according to the 

parameter configuration.   

 

 

Firstly, the auto download function should be used in combination with the CEIBA2 

platform. The user can create the auto download task via the CEIBA2 platform and the platform 

Содержание VT5500-G-LTE

Страница 1: ...ithout notice No liability will be accepted by VisionTrack for any errors or omissions in this information VT5500 G LTE 5 CHANNEL FULL HD 1080P MOBILE DVR The VT5500 G LTE is a full HD 1080p ruggedised 5 channel mobile digital video recorder MDVR designed for vehicle surveillance and monitoring with built in connectivity advanced video compression and GPS positioning technology for live tracking T...

Страница 2: ...ut Total Resource Video Signal Standard Control Mode OS Linux 3 18 20 Easy check network VT CP4 mouse 3G 4G 4 channels AHD 1080P 1 channel IPC LTE 1080P 1 channel 4x720P 30fps 1x1080P 30fps 4x1080P 15fps 1x1080P 30fps Electrical level 1Vpp Impedance 75Ω Optional PAL 5 channels 1 channel IPC audio input Electrical level 2Vpp Input impedance 4 7kΩ GPS information alarm vehicle no speed date time Sem...

Страница 3: ...VT CP4 Monitor 1 MIC interface DC8 36V ignition signal 5V 1A Max Power Consumption 32W Standby Power Consumption Operating Temperature Operating Relative Humidity 0W 400 C 700 C With heater or 100 C 700 C 8 90 No Condense RS232 x 1 8 inputs 2 outputs 1 channel pulse speed detection Playback Network Sensor Storage Interface Power Environment Locating Specifications Physical dimensions VisionTrack C...

Страница 4: ...ith the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following...

Страница 5: ...d guide us to better use its functions Please note the operation is for professionals only 2 Main Menu 2 1 Business Menu Click Business Menu and the following screen is displayed The user doesn t need to enter the password to go into Business Menu and common users and drivers all have access to it ...

Страница 6: ...e numbers on the device is not allowed Like the cellphone Records all call records including received calls missed callas and dialed calls 2 1 2 Short Message Short message is divided into read mailbox and unread mailbox Short message can only be sent by the business platform 2 2 User Login Click Login on the preview screen and the user needs to select his username and enter the password to log in...

Страница 7: ... screen then he doesn t need to re enter the username and password the next time he enters the settings screen If the user clicks Logout then he needs to re enter the username and password the next time he enters the settings screen 3 Main Functions 3 1 Basic Functions 3 1 1 Recording Search Click REC search to enter the recording search screen The user can search primary sub stream recording at a...

Страница 8: ...cording search depends on recording types instead of the storage way Recording is classified as all alarm recording and regular recording To select all search eligible channels to select alarm recording only search alarm linkage recording to select regular recording search all recording other than alarm recording ...

Страница 9: ...ording To export recording the user can select time period drag the timeline or directly enter the time Then he can click Start time to set the start time for export and switch to end time set by the following photo Click End time to confirm the time period for export and the size of exported files Click Export recording and select the format to export recording Integrated data package and export ...

Страница 10: ...me periods Log is classified as operation log alarm log locked log and P2 operation log When selecting the alarm log if the log has recording to link with then the Play button corresponding to the log can be selected Otherwise it is not optional The user can directly play back and export the alarm log with video ...

Страница 11: ...ultiple choices the device follows the order of satellite NTP sync and central server When time synchronization by satellite fails resort to NTP If NTP also fails turn to central server for time synchronization Time synchronization by central server is performed by the CEIBA2 server For the cause of time zones the user needs to set Daylight Saving Time DST He can ...

Страница 12: ...ter the car key is off If the operation screen is still the settings screen then countdown is not started The description mentioned above also applies to timed shutdown Timed shutdown is impossible in the settings screen The function won t be available until the user exits the preview screen Light off time the function is to set the light off function for CP4 and be applied for driving at night Si...

Страница 13: ...estored Car key is off low voltage protection is enabled When detecting the current voltage is below the protection voltage the device enters the off mode the device doesn t work The device won t be awaken after the voltage is restored when the low voltage protection function is not enabled 7V is taken as the criteria for low voltage protection by default low voltage protection will be triggered w...

Страница 14: ...of operation timeout the time users wait to exit to the preview interface after entering the settings screen 3 1 7 Network For vehicles to go online three network access ways are optional local connection WIFI connection and 3G 4G connection Server configuration means the server configured for device report Up to 6 configurations can be supported by the server Please note that 3 configurations can...

Страница 15: ...ample photos captured by MDVR can be configured to upload to the FTP server The user can upload photos to a corresponding server according to the parameter configuration Firstly the auto download function should be used in combination with the CEIBA2 platform The user can create the auto download task via the CEIBA2 platform and the platform ...

Страница 16: ... enters the sleep mode and waits for the reboot and tries to download again after returning to the depot and failing to connect to the service When the download tasks are full or the set AP reaches the upper limit the platform notifies the device to enter the sleep mode and simultaneously informs the device when to reboot this function helps vehicles avoid resources waste when waiting for the upgr...

Страница 17: ...2x2 and 3x3 They respectively indicate single screen 4 screens and 9 screens For each screen the user can set which channels to display Likewise he she can set the staying time for each switch Live view OSD The user needs to distinguish live view OSD and recording OSD live view OSD means OSD information of the preview screen However for OSD information of AHD recording it needs to select recording...

Страница 18: ...2 Mirror recording completely back up the HDD data to the SD card 3 Alarm recording backup the recording will be stored only when an alarm is generated 4 None it is loop recording for the dual SD card Check the channel that requires sub stream settings The user can set the sub stream recording by the click The use can click to make recording settings of sub stream Recording OSD The user can choose...

Страница 19: ...s into parameters and IP address will be reassigned after the re plug 2 MDVR with POE interface IP address of IPC requires quick settings since the device needs to connect to the switch MDVR will automatically search IPC and configure the searched IPC with IP address after connecting to the switch IP address starts from 10 100 100 100 and skips the IPC network segment address For IPC searched by q...

Страница 20: ...irectly checks and views IP address 2 the user adopts ONVIF protocol then he clicks the IPC setup button and fills in information related to IP address Support to configure the IPC network segment address If the device IP assigns a certain address this address will be skipped when the device automatically searches and configures IP IPC search screen If IPC is searched on this screen then its IP ad...

Страница 21: ...se note that modifying IP address here is not to modify IP address of IPC but rebind other IPC For intelligent IPC channels such as DSM ADAS and BSD channels calibration mode and normal recording mode are optional 3 2 4 PTZ Operation mode serial port ONVIF and N9M ONVIF and N9M protocols are applied to control IPC using different protocols ...

Страница 22: ...ata Collection 3 3 1 General Device sensor connection cable For IO cables IO1 IO8 parameters can be set on this screen Voltage and pulse are optional for the signal source IO purpose can be chosen according ...

Страница 23: ...eripherals Each standard peripheral of Streamax has a fixed code When 485 bus connects several peripherals of the same standard like an extra temperature humidity sensor how the user can tell which sensor the temperature comes from In this case the user must write an address code for each peripheral by the tool offered by Streamax For example to connect to three sensors these sensors shall be numb...

Страница 24: ...are optional Mileage basic value calibration and Auto calibration are supported Mileage basic value calibration function Calibration means the user sets an initial value for the total mileage The flow limit function The user can limit the transmission speed of uploading data to the platform by this function ...

Страница 25: ... 3 2 Advanced Connected to the passenger counter named P2 and temperature humidity sensor 3 3 3 Snapshot Settings Snapshot includes timed snapshot and triggered snapshot manual trigger and alarm linkage ...

Страница 26: ...to playback 3 3 4 ECO Driving There are two ways of calibration remote calibration and local calibration Details are shown below Remote calibration 1 The platform sends a piece of vehicle information to MDVR such as license plate number engine model and OBD upgrade file engine model and OBD upgrade file need to be bound in advance 2 MDVR compares OBD upgrade file version in GDS 6 axis sensor and t...

Страница 27: ... screen 4 The program automatically compares license plate number of the vehicle and license plate numbers in the vehicle information sheet one by one until finds records of the same license plate number Likewise the program acquires the OBD upgrade file version number and compares it with version numbers in OBD If version numbers are different then upgrade the OBD version to the required version ...

Страница 28: ...3 3 5 Maintenance Operation and maintenance configuration the user can set a fault range Once data falls out of the range an alarm will be given 3 4 Intelligent Alarm ...

Страница 29: ...g the alarm can last before being off Alarm duration indicates the alarm is recorded as effective alarm only once after being repeatedly given in a certain period of time IO alarm Linkage settings are offered to each IO alarm Speed alarm once the speed is higher than the set speed real time alarm log will be generated and uploaded to the platform ...

Страница 30: ...mon trigger condition namely Effective alarm time Effective alarm time means that one alarm is regenerated in the set time after the previous alarm is off These two alarms are regarded as the same alarm Therefore the processing result is one piece of log is recorded and alarm is reported to the platform only once ...

Страница 31: ...nsor can set alarm for collision or changes in the position as well as link with the screen for settings Geo fence support switch on and off of the Geo fence Temperature humidity alarm settings the user can set trigger conditions and linkage screen ...

Страница 32: ...the alarm Channel recording will be marked as alarm recording Post recording the time recording continues after the alarm is off Lock the user can set whether to lock the alarm recording Linkage screen the user can set to display the preview screen after the alarm ...

Страница 33: ...can be set according requirements of users The user needs to check alarm snapshot in linkage settings to upload evidence photos and then set in Data collection Snapshot settings After determining the ADAS calibration height the user can set the ADAS algorithm height cm and inch are optional ...

Страница 34: ......

Отзывы: