background image

 

Set Relay Configuration 

The relay configuration sets the behavior of the output relay on activation. 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode 

*

 (Master Code) #

 

2. Pulse Mode 

 

OR 

 

2. Toggle Mode 

4 (1-99) #     

(factory default)

 

The relay time is 1-99 seconds. (1 is 500mS.) (Default 

is 5 seconds)

 

 

4 0 #   

Set the relay to ON/OFF Toggle mode 

3. Exit 

 

Set Doorbell 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode 

*

 (Master Code) #

 

2. Doorbell OFF 

OR 

2. Internal Doorbell ON 

OR 

2. External Doorbell ON 

OR 

2. Internal & External Doorbell ON 

5 0 # 

 

5 1 # 

 

5 2 # 

 

5 3 # (factory default)

 

3. Exit 

Remarks:

 

Press the doorbell on keypad, there will be 2 times ‘dingdong’ from mini controller. 

 
Set Safety Mode 

In safety mode, it can be set to deny access for 10 minutes after 10 failed PIN/card attempts in 10 minutes 

(Factory default is OFF).   

 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode 

*

 (Master Code) #

 

2. Strike-Out OFF 

OR 

2. Strike-Out ON 

6 0 # 0 #   

(factory default)

   

 

6 0 # 1 #   

3. Exit 

 

Set Anti-tamper Alarm 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode 

*

 (Master Code) #

 

2. Anti-tamper Alarm OFF 

  OR 

2. Anti-tamper Alarm ON 

6 1 # 0 #     

 

6 1 # 1 #   

(factory default) 

3. Exit 

Содержание VIS-8009

Страница 1: ...433MHz Outdoor Wireless Keypad Reader Access Control 500 Users Range of 165 Feet Delay and On Off Toggle Mode Battery Operated Standalone No Software VIS 8009 User Manual www visionistech com...

Страница 2: ...requency 244MHz Communication Distance 50m Maximum 165 feet Relay Contact Load 2Amp Maximum Environment Operating Temperature Operating Humidity Outdoor Wireless Keypad 40 C 60 C 40 F 140 F 0 86 RH Ph...

Страница 3: ...r into Program Mode Shines per 1 5 seconds One long beep Invalid PIN 3 beeps Exit from the Program Mode One beep Low battery reminding RED and GREEN alternately shines 2 times Wireless button ON Wirel...

Страница 4: ...Using Auto ID Allows VIS 3200 to assign Card to next available User ID number OR 2 Add Card Select Specific ID Allows Master to define a specific User ID to associate the card to 1 Read Card The cards...

Страница 5: ...e PIN 1234 to cards when adding Read Card Old PIN New PIN Repeat New PIN 2 Change PIN By PIN User ID Old PIN New PIN Repeat New PIN 3 Exit Delete Users Programming Step Keystroke Combination 1 Enter P...

Страница 6: ...N OR 2 External Doorbell ON OR 2 Internal External Doorbell ON 5 0 5 1 5 2 5 3 factory default 3 Exit Remarks Press the doorbell on keypad there will be 2 times dingdong from mini controller Set Safet...

Страница 7: ...ith an optional magnetic contact or built in magnetic contact of the lock if the door is opened by force the inside buzzer and external alarm if there is will both operate they can be stopped by valid...

Страница 8: ...lease repeat the setting To pair the wireless button and the controller Mini Controller Remove the back cover and press the button Pair Wireless Button Remove the back cover and press the button Pair...

Страница 9: ...sed and the LED will be in YELLOW if the wireless button has a low battery the LED will shine in RED and GREEN twice alternately then please replace the batteries for the keypad and the button within...

Отзывы: