![Visionis VIS-3018 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/visionis/vis-3018/vis-3018_installation-manual_1032519009.webp)
3.3 Wiring Cables
Purpose:
Wire the cables between controller and card reader, thus to establish the communication between
them.
Steps for RS-485 communication mode:
1. Set the DIP switch of No. 6 as 0.
2. Set the DIP switch of No. 1 ~5 for RS-485 address and reading card mode. For details, please
refer to
3.2 Introduction for DIP Switch
.
3. Wire the cable between controller and card reader as shown below.
Figure 3-3 Wiring for RS-485 Communication Mode
Steps for Wiegand communication mode:
1. Set the DIP switch of No. 6 as 1.
2. Set the DIP switch of No. 5 and 7 for reading card mode and Wiegand protocol. For details,
please refer to
3.2 Introduction for DIP Switch
.
3. Wiring the cable between controller and card reader as shown below.