Operation
1.
Power-on Mode: 1) Install the battery into the module 2) The detector will emit a
beep in 0.5 second and the three LEDs will flash once quickly. 3) Close the bracket.
The CO detector will alarm once remove the bracket.
2.
Stand-by Mode: The Green LED flashes one time every 60 seconds.
3.
Alarm Mode (It’s the status when the alarm is triggered.): If a certain density of
CO is detected, an audible alarm with 4 beeps, pause 5 seconds and 4 beeps will
occure. The red LED will flash continuously and rapidly. Meanwhile, the CO
detector will send an alarm sensor report (type: CO alarm, state: alarm) to the
user’s controller and also the CO dectecor will send an alarm sensor report (type:
CO alarm, state: No alarm) while the alarm off.
4.
Error Mode: If the CO detector beep once and yellow LED flash three times every
minute, it indicates the CO detector is not working properly. Please require to
repaire or service.
5.
Low battery warning Mode: The yellow LED will flash once every minute with a
“beep” sound.
6.
Low sensitivity Mode: The yellow LED will flash twice every minute with a “beep”
sound. It indicates the CO detector has internal problem, please replace the unit.
7.
Tamper Mode: The yellow LED will go solid and the detector will emit a short beep
every minute untill the CO detector is mounted back to the bracket properly.
8.
End of life signal Mode: The yellow LED will flash four times every minute with a
short “beep” sound. It indicates the CO detector is reaching to the end of useful life,
please replace with a new unit.
9.
Testing Mode: Test the alarm by pushing test switch until the user hear 4 short
beeps and three LEDs flash synchronously in five senconds. Then, the CO detector
will send an alarm sensor report (type: CO alarm, state: alarm) to the user’s
controller and also the CO dectecor will send an alarm sensor report (type: CO
alarm, state: No alarm) while the alarm off. Please note if the CO detector only beep
once and yellow LED falsh three times every minute, it indicates the CO detector is
not working properly. Please require to repair or service.
10. Battery Power indicator: The detector will report the current status of battery
capcity to the user’s contorller.
11. Self-Protection Mode: If the cover of detector removed from bracket after 8 sec,
the detector will send an alarm report (type:0*02, level:0*FF) to the Z-Wave
Interface Controller , and the Yellow LED will on contiuously and the detector will
sound.
-3-
12. Silence Mode: The user could press the test switch to get into silence mode to turn
off the alarm temporarily when the CO detector alarm. Meanwhile, the red LED will
flash continually. The silence function will automatically turn into normal operation if
the CO concentration around the CO detector is still at alarming level after 4
minutes of silence mode.
Federal Communications Commission Statement
This equipment has been followed to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interferene by one of the following measures:
-- Reorient or relocate the receiving antenna,
-- Increase the separation between the equipment and receiver,
-- Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless CO detector is free from physical defects in
material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. Vision does not issue any refunds. This warranty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to:
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent
use; (2) units which have been subject to unauthorized repair, opened, taken apart, or
otherwise modified; (3) units not used in accordance with instruction; (4) damages
exceeding the cost of the product; (5) transit damage, initial installation costs, removal
cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Install second-floor alarms at the top of first-to-second floor stairwell.
Install basement alarms at the bottom of the basement stairwell.