Introduction
Thanks for choosing the Vision’s wireless CO detector
of the home security device. This
detector is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network. Every mains
powered Z-Wave
™
enabled device acts as a signal repeater and multiple devices result
in more possible transmission routes which helps eliminate “RF dead-sports”.
Z-Wave
™
enabled devices displaying the Z-Wave
™
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave
™
enabled networks. This detector is designed to sense CO
that comes into
the detector chamber and send Z-Wave
™
signal when the detector detects a certain
density of CO, the horn of CO detector will sound.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave™ (ZS6301N)
Frequency Range:
868.42MHz (ZS6301EU)
908.42MHz (ZS6301US)
921.42MHz (ZS6301BR)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10
°C
~ 50
°C
(14
°F
~122
°F
)
Battery: Panasonic CR123A * 3PC
Z-Wave
™
™
™
™
Command Classes:
COMMAND_CLASS_ALARM
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SENSOR_ALARM
COMMAND_CLASS_VERSION
COMMAND_CLASS_WAKE_UP_V2
* COMMAND_CLASS_SENSOR_ALARM Mapping
1pc
1pc
2pcs
3pc
1pc
ZS 6301 CO
Detector
Bracket Holder
Plastic Anchor &
Screw
Double A Battery
Installation &
Operation Manual
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZS6301.
1.
Remove the bracket from the detector by rotating it counter-clockwise.
2.
Place the bracket where you are going to install the detector. In each of keyhole
slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill
bit, drills two holes at the marks and insert plastic anchor, and attached the bracket
by using the screws.
3.
Open the battery cover to insert the batteries, and then replace the cover. Fix the
detector with bracket by rotating it clockwise.
4.
For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into
“inclusion” mode, and following its instruction to add the ZS 6301 to your controller.
To get in the “inclusion” mode, the distance between detector and controller is
suggested to be in one meter. Press the program switch of ZS 6301 for 1 second at
least to be included.
For “Exclusion” from (removing from) a net work: Put the Z-Wave™ Interface
Controller into “exclusion” mode, and following its instruction to delete the ZS 6301
from your controller. Press the program switch of ZS6301 for 1 second at least to be
excluded.
Please note: LED setting light will flash (red) continuously in Exclusion condition.
For “Awake” mode: it is to leave the “Sleep” mode by pressing the program switch
for 1 sec. at least to allow the Z-Wave™ Interface Controller to do “Inclusion”,
“Exclusion”, “Association” and to reply and receive the commands from controller. It
will take about 5 sec. and the red LED light on for awaking the system. LED light will
be off after setting.
For “Association”: After “Awake” mode, then put the Z-Wave
™
Interface
Controller into “Association”, and following its instruction to associate the ZS6301
with other device. Afterward the ZS6301 will get into “Sleep” mode for power saving.
One association group supports 5 nodes.
For “Auto Wake-up” mode: The users could set Auto Wake-Up mode in min. 10
minutes to max. a week. Default setting is based on 1 hour, each increment in 200
sec.
5.
Suggestion of the Smoke Detector Location:
COMMAND_CLASS_BASIC
-1-