Introduction 

 

Thanks for choosing the Vision’s wireless CO detector

 

of the home security device. This 

detector is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking 
technology) and is fully compatible with any Z-Wave™ enabled network. Every mains 
powered Z-Wave

  enabled device acts as a signal repeater and multiple devices result 

in more possible transmission routes which helps eliminate “RF dead-sports”. 
Z-Wave

  enabled devices displaying the Z-Wave

  logo can also be used with it 

regardless of the manufacturer, and ours can also be used in other manufacturer’s 
Z-Wave

  enabled networks.    This detector is designed to sense CO

 

that comes into 

the detector chamber and send Z-Wave

  signal when the detector detects a certain 

density of CO, the horn of CO detector will sound. 

 

Product Description and Specification 

 

*** For indoor use only *** 

 

 

Specification:   

Package Content:   

Protocol: Z-Wave™ (ZS6301N) 
Frequency Range:   

868.42MHz (ZS6301EU) 
908.42MHz (ZS6301US) 
921.42MHz (ZS6301BR) 

Operating Range: Up to 100 feet line of sight 

Operating Temp.: -10

°C

~ 50

°C

 (14

°F

~122

°F

Battery: Panasonic CR123A * 3PC 
Z-Wave

  Command Classes:   

COMMAND_CLASS_ALARM 

 

COMMAND_CLASS_ASSOCIATION_V2 

 

COMMAND_CLASS_BATTERY 

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

 

COMMAND_CLASS_SENSOR_ALARM 

 

COMMAND_CLASS_VERSION 

 

COMMAND_CLASS_WAKE_UP_V2 

 

* COMMAND_CLASS_SENSOR_ALARM Mapping 

1pc 
1pc 
2pcs

 

 
 
3pc 
1pc 

 

ZS 6301 CO 
Detector 
Bracket Holder 
Plastic Anchor & 
Screw 
Double    A    Battery 
Installation & 
Operation Manual

 

 

Installation 

 

Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to 
the installation guide of Z-Wave™ Interface Controller before installing ZS6301.

 

 

1. 

Remove the bracket from the detector by rotating it counter-clockwise. 

 

2. 

Place  the  bracket  where  you  are  going  to  install  the  detector.  In  each  of  keyhole 
slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill 
bit, drills two holes at the marks and insert plastic anchor, and attached the bracket 
by using the screws. 

3. 

Open the battery cover to insert the batteries, and then replace the cover. Fix the 
detector with bracket by rotating it clockwise. 

 

4.

 

For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into 
“inclusion” mode, and following its instruction to add the ZS 6301 to your controller. 
To get in the “inclusion” mode, the distance between detector and controller is 
suggested to be in one meter. Press the program switch of ZS 6301 for 1 second at 
least to be included.   

 

For “Exclusion” from (removing from) a net work: Put the Z-Wave™ Interface 
Controller into “exclusion” mode, and following its instruction to delete the ZS 6301 
from your controller. Press the program switch of ZS6301 for 1 second at least to be 
excluded.

 

Please note: LED setting light will flash (red) continuously in Exclusion condition.   

 

For “Awake” mode: it is to leave the “Sleep” mode by pressing the program switch 
for 1 sec. at least to allow the Z-Wave™ Interface Controller to do “Inclusion”, 
“Exclusion”, “Association” and to reply and receive the commands from controller. It 
will take about 5 sec. and the red LED light on for awaking the system. LED light will 
be off after setting.       

 

For “Association”: After “Awake” mode, then put the Z-Wave

  Interface 

Controller into “Association”, and following its instruction to associate the ZS6301 
with other device. Afterward the ZS6301 will get into “Sleep” mode for power saving.   
One association group supports 5 nodes.   

 

For “Auto Wake-up” mode: The users could set Auto Wake-Up mode in min. 10 
minutes to max. a week. Default setting is based on 1 hour, each increment in 200                                                                                           
sec.

 

 

5.

 

Suggestion of the Smoke Detector Location:

 

       

         

 

         

 