Introduction
Thanks for choosing the Vision
’s wireless PIR motion sensor of the home security device.
This sensor is a Z-Wave
TM
enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave
TM
enabled network. Every mains
powered Z-Wave
TM
enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes
which helps eliminate “RF dead-spots”.
Z-Wave
TM
enabled device displaying the Z-Wave
TM
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer
’s Z-Wave
TM
enabled networks. This sensor monitors movement, and send Z-Wave
TM
signal when
movement is detected inside the building.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave
™ (ZM3102N/ZM4102AH)
Frequency Range:
868.42MHz (ZP3102EU)
908.42MHz (ZP3102US)
921.42MHz (ZP3102BR)
920-928MHz (ZP3102JP)
865.22MHz (ZP3102IN)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15
°C
~ 40
°C
(5
°F
~104
°F
)
Battery: Panasonic CR123A * 1PC
Z-Wave Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_ALARM_V2
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_BATTERY
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_MULTILEVEL_V4
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_WAKE_UP_V2
1pc
1pc
1pc
1pc
ZP 3012 sensor
Adhesive tape for sensor
CR123A Lithium Battery
Installation & Operation Manual
Installation
Notice: If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing ZP3102.
1. Release cover tab to open the cover.
2. Insert a CR123A battery into the battery compartment and LED will start to flash slowly,
which means the sensor has not yet been
“inclusion”.
3. Close the cover back to sensor.
4.
For
“Inclusion”
in (adding to): Put the Z-Wave
TM
Interface Controller into
“inclusion”
mode, and following its instruction to add the ZP3102 to your controller. To get in the
“inclusion” mode, the distance between sensor and controller is suggested to be in one
meter. Press the program switch of ZP3102 once. The LED on the ZP3102 should
stop
flashing, if not, please try again.
For
“Exclusion”
from (removing from) a network: Put the Z-Wave
TM
Interface
Controller into
“exclusion” mode, and following its instruction to delete the ZP3102 to
your controller. Press the program switch of ZP3102 once to be excluded. The LED
on the ZP3102 should start to flash.
For
“Association”
: removing the cover of the ZP3102 to get into
“Awake” mode, then
put the Z-Wave
TM
Interface Controller into
“association”, and following its instruction to
associate the ZP3102 with other device. Close the cover back after
“association”
done, afterward the ZP3102 will get into
“Sleep” mode for power saving. Support one
association group (5 nodes).
Note:
“Awake
” mode: it is to leave the “Sleep” mode by removing the cover of ZP3102,
to allow the Z-Wave
TM
Interface Controller to do
“Association”.
5. Using adhesive tape to mount ZP3102 at 2 meters above surface. To enhance
proper operation, place ZP3102 on the angle which can detect the room widely. The
solid area means the detector
’s coverage range.
NOTE: The user needs to get the controller for receiving the current temperature except
when the tempe1 or -1 degree then the sensor will automatically report to
the controller.
-1-