Introduction 

 

Thanks for choosing the Vision’s wireless siren & strobe alarm

 

of the home security device. 

This siren is a Z-Wave

  enabled device (interoperable, two-way RF mesh networking 

technology) and is fully compatible with any Z-Wave™ enabled network. Every main 
powered Z-Wave

  enabled device acts as a signal repeater and multiple devices result in 

more possible transmission routes which helps eliminate “RF dead-sports”. 
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it 
regardless of the manufacturer, and ours can also be used in other manufacturer’s 
Z-Wave™ enabled networks. This product will sound a loud siren and flash a strobe light 
when an alarm message or alert is received on any Z-Wave

  enabled network.   

 

Product Description and Specification 

 

*** For indoor use only *** 

 
 
 
 
 
 
 
 
 

Specification:   

Package Content:   

Protocol: Z-Wave

  (ZM3102N) 

Frequency Range:   

868.42MHz (ZM1602EU) 
908.42MHz (ZM1602US) 
921.42MHz (ZM1602BR) 

Operating Range: Up to 100 feet line of sight 
Loud Audible Alarm: > 105Db@1meter 
LED Strobe Lighting 
Operating Temp.: -15

°C

~ 60

°C

 (5

°F

~140

°F

Battery: 4pcs x AA Energizer Batteries 

Z-Wave

  Command Classes:   

COMMAND_CLASS_BASIC 

 

COMMAND_CLASS_BATTERY 

 

COMMAND_CLASS_CONFIGURATION 

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

 

COMMAND_CLASS_SWITCH_BINARY 

 

COMMAND_CLASS_VERSION 

Note: 

COMMAND_CLASS_BASIC Mapping

                                   

1pc 

1pc 

2pcs 

4pcs 

1pc 

ZM 1601 Siren 

Adhesive tape 

Screw 

AAEnergizer Batteries 

Installation & Operation 

Manual 

Installation 

 

Note: If you are installing the entire Z-Wave™ system for the first time, please refer to the 
installation guide of Z-Wave™ Interface Controller before installing ZM 1601. 

 

1.

 

Remove the bracket from the siren by press the locking tab, and then gently slide 
up the siren. Observe the correct polarity before insert the batteries. 

 

2. 

Using the screws or adhesive tape to affix the bracket on the chosen location. 

3.

 

Slide back the cover and screw fastening with the front cover, the LED should go off.

 

 

 

 

4. 

For “Inclusion” in (adding to) a network: Put the Z-Wave

  Interface Controller 

into “inclusion” mode, and following its instruction to add the ZM 1601 to your 
controller. To get in the “inclusion” mode, the distance between siren and controller 
is suggested to be in one meter. Open the bracket and press the program switch of 
ZM 1601 for 1 second at least & release to be included. After setting, the LED 
Setting Lighting should go off, if not, please try again. 

 

For “Exclusion” from (removing from) a network: Set up the Z-Wave

  Interface 

Controller into “exclusion” mode, and following its instruction to delete the ZM 1601 
from your controller. Press the program switch of ZM 1601 for 1 second at least & 
release to be excluded. 
Note: LED setting light will flash (orange color) continuously in Exclusion condition.   

5. 

Configuration command class:   

Parameter 0: Siren/ Strobe Mode, 1 Byte Value: 0=siren and Strobe enable   

(default), 1=siren only, 2= Strobe only. 

Parameter 1: Alarm auto stop time command, 0=30 seconds (default), 1= 60 secs,   

2= 120 secs, 3= siren will not automatically stop. 
 

Operation 

 
 

1. 

Normal operation, the LED light will not on.

 

2. 

Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will enter 
Self-Protection  Mode.    If the  back cover  is  opened  will  trigger  the Self-Protection 
Mode. The alarm time is default 30 seconds. 

3. 

User’s controller should support Z-wave FLiRS technology. 

4. 

Alarm Mode (It’s the status of alarm triggered): It’s based on the user’s 
configuration setting of LED flash ON/OFF and Siren ON/OFF. 

Note: for Default setting-Siren/Strobe Mode-Parameter will be All enable; Alarm   
Auto Stop Time-Parameter will be 30 sec. 

5. 

For safety reason, replace new battery whenever ZM 1601 is triggered. 

 

 

     

 

 

LED setting light 

-2- 

-1- 

COMMAND_CLASS_SWITCH_BINARY

 