Menu #21 -  IP

 

Adjustable list, displays the IP address of SNMP 

 

Menu #22 -  Sub

 

Adjustable list, displays the address of net mask 

 

Menu #23 -  GW

 

Adjustable list, displays the gateway address of SNMP 

 

Menu #24 -  TR1

 

Adjustable list, displays the TRAP1 address of SNMP 

 

Menu #25 -  TR2

 

Adjustable list, displays the TRAP2 address of SNMP 

 

 

3.1.3      Menu assistant manual

 

 

1.     Press up/down key to amend the IP address menu that should be 

amended, press „ to choose the amend place, push 

\

 

currently value 

+\-1, press 

 

  to enter into save and 

exit. 

 

For example, amend IP setup menu, IP: 192.168.000.015; if change 5 to 6, 

use 

 

 key to choose the place of 5, then press 

 key to change 5 to 

6, then press 

 

 to save amended IP:192.168.000.016 

 

2.     The manual for the control way of RF modulation 

 

The default control way is AGC. That is, when you use 

 

or 

 to switch 

the menu to the modulation control way, it shows: RF Mode = AGC. 
At this time, when you press 

 

, it shows: RF Mode =      ; when you 

press 

 

or 

, it shows:   RF Mode = MGC, press 

 

  to save, then the 

switch from the AGC to MGC is done. 

 

If you want to re-switch the modulation control way to the AGC, just press 

 

 when the menu shows RF Mode = MGC, it will show RF Mode =     , 

then click 

 

or 

, Press the 

 

 to save, it shows: RF Mode = AGC. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 6 of 7 

Содержание GS8510 Series

Страница 1: ...i is si io on n 1 15 55 50 0n nm m E Ex xt te er rn na al l M Mo od du ul la at ti io on n O Op pt ti ic ca al l T Tr ra an ns sm mi it tt te er r G GS S8 85 51 10 0 S Se er ri ie es s U US SE ER R MA AN NU UA AL L ...

Страница 2: ... INSTALLATION 1 2 1 Unpacking 1 2 2 Transmitter Mounting and Power Connection 1 2 3 RF connection 2 2 4 Optic connection 2 3 0 TRANSMITTER CONTROLS INDICATORS AND ALARMS 4 3 1 The operation of the panel 4 4 0 GUARANTEE AND REPAIR ITEMS 7 ...

Страница 3: ...rk management 1 1 back up power supply and casing temperature auto control All the optical port can be installed in the front panel The back panel is also available if needed 2 0 INSTALLATION 2 1 Unpacking Inspect the shipping boxes for any obvious damages Unpack the unit from all packaging boxes Inspect the appearance of the unit for any shipping damages Document and inform the shipping company a...

Страница 4: ...F connection Connect the RF cable the connector on TX rear panel RF connector is F type plug F Female F male Optional The resistance is 75Ω 2 4 Optic connection 1 Considering for protection safety all the fiber optic connector need protective cover during transportation 2 In order to ensure the insertion loss return loss the end interface of fiber optic connector should be cleaned Please don t dir...

Страница 5: ...acturer s pulling tension or bend radius specifications when removing fiber bulkhead connector plate To remove the transmitter optical connector plate remove the screw on the far left of the optical plate and remove the screw on the far right of the optical plate Do not remove the screws on the optical bulkhead connector Slowly remove the optical connector plate from the rear panel and disconnect ...

Страница 6: ...ply B Turn on power switch in the rear panel Front panel display KEY OFF Laser Status lamp Red Alarm Status lamp Green LAN With network management lamp shows green status indication C Press laser start up key switch Front panel shows KEY ON laser status lamp turns green from red and machine enters self checking After checking it enters working status and display Descriptor 3 1 2 Start up main menu...

Страница 7: ...OMI adjustable the range is betweent 7 3dBm 7 3dBm step 0 3 0 2 dBm Menu 11 RF Level Read only menu displays RF level and shows LOW NORMAL HIGH Menu 12 SBS SBS restrain 135 16 18dBm optional Menu 13 SBS State Read only menu tells the situation of SBS Menu 14 CSO State Read only menu tells the situation of CSO Menu 15 Date Read only menu tells the date Menu 16 Version Read only menu tells the versi...

Страница 8: ...d exit For example amend IP setup menu IP 192 168 000 015 if change 5 to 6 use key to choose the place of 5 then press key to change 5 to 6 then press to save amended IP 192 168 000 016 2 The manual for the control way of RF modulation The default control way is AGC That is when you use or to switch the menu to the modulation control way it shows RF Mode AGC At this time when you press it shows RF...

Страница 9: ...nduced factor If the Red lamp sparking Alarm please send the product back to manufacturer for repairing The user should not open the top cover for repair otherwise even within guarantee period maintain and material fee will be charged 3 Lifelong maintain and upgrade can be provided even though the guarantee period is expired 4 If component is damaged by man induced factor material fee will be char...

Отзывы: