1. INTRODUCTION 

 
This UPS is specially designed for personal computers with multi-functions.  Its light weight and compact design fits perfectly 
into limited workspaces.  The UPS-input is equipped with automatic voltage regulation (boost and buck AVR) to stabilize 
input voltage range.  It has also a built-in cold start function, which enables the UPS for start-up without mains supply.  
Although it’s a small UPS, it disposes the main features listed below: 

 

control by microprocessor guarantees a high reliability; 

 

equipped with automatic voltage regulation (boost and buck AVR); 

 

green power function for energy saving; 

 

cold start function; 

 

automatic restart while mains supply recovery; 

 

compact size, light weight; 

 

provides mains supply overload protection. 

 
 

2. SAFETY INSTRUCTIONS 

 

 

This UPS uses voltages that may be dangerous.  Do not attempt to disassemble the unit; it contains no user 
serviceable parts.  Repairs should only be executed by plant service. 

 

The battery voltage is 12Vdc.  These are internal, sealed, maintenance-free, 6 cells lead-acid batteries.

 

 

The UPS must be connected to a mains socket with circuit-breaker.  Connect the appliance only to a mains socket 
with grounding.

 

 

In case of an emergency, press the OFF-button and pull the mains plug for interrupting completely the power 
supply to the UPS. 

 

Do not let attain any liquids or foreign objects into the UPS appliance; that’s why no beverage or other liquid-
containing vessels should be placed on or near the appliance. 

 

This unit is intended for installation in a controlled environment (temperature and humidity).  Do not install it in 
locations with standing or flowing water or excessive humidity. 

 

Do not plug the input cable of the UPS in its own output. 

 

Do not connect multiple plugs or surge protections to the UPS unit. 
 

Содержание BP650

Страница 1: ......

Страница 2: ...ergy saving cold start function automatic restart while mains supply recovery compact size light weight provides mains supply overload protection 2 SAFETY INSTRUCTIONS This UPS uses voltages that may be dangerous Do not attempt to disassemble the unit it contains no user serviceable parts Repairs should only be executed by plant service The battery voltage is 12Vdc These are internal sealed mainte...

Страница 3: ...he batteries When the batteries are replaced utilize the same quantity and type of sealed lead acid battery The ambient temperature may not exceed 40 C For maintaining the battery lifetime we advise an ambient operating temperature of 20 C to 25 C Ensure during the installation of the appliance that the sum of the residual current of the UPS and of the connected load does not exceed 3 5mA Caution ...

Страница 4: ... left green LED is lighting the 1st to 4th green LED are gradually lighting and in line with the load level 1600 2200VA Battery mode The yellow LED is flashing 650 1300VA The left green LED is flashing the 1st to 4th green LED are gradually lighting and in line with the autonomy level 1600 2200VA Fault mode The red LED is lighting LCD 4 2 Back panel Input mains power supply Output receptacles USB ...

Страница 5: ...PS unit in a protected environment that provides adequate ventilation around the unit and that s free from excessive dust corrosive vapours and conducting polluting substances Do not operate your UPS in an environment where the ambient temperature or humidity is high Furthermore maintain a minimum distance of 20 cm between UPS unit and a monitor for avoiding harmful interference 5 4 Connection Plu...

Страница 6: ...onnected load is in accordance with the denoted performance see specifications When the power failures back up time is shorten 1 Overload of the UPS 2 The battery voltage is too low 3 Battery fault because of too high operating temperature or because of malfunction of the battery 1 Remove some non critical loads 2 Charge the battery during 8 hours or more 3 Replace the battery with a new one of sa...

Отзывы: