6  INSTRUCTIONS FOR THE MERTIK MAXITROL GV60

 WARNING

Ensure the fuel supplied to the unit is clean and free.
The unit must not be turned on if the glass pane(s) is not 
present and/or is broken.

Ensure the fuel supplied to the unit is clean and free 

from particles and moisture.

Before a gas supply pipe (new or existing) is connected to the 
main gas pipe at the gas meter and to the gas control block 
of the unit, clean and dry compressed air needs to have been 
blown through it. Copper and aluminium pilot light pipes that 
have been cut must be deburred and blown clean before they 
are connected.

Heat, moisture and dust are a threat to all electronic 

components.

Protect the electronic gas control 

until

 all construction, 

plastering and paintwork has been completed. If you cannot 
avoid this work, then protect the control against dirt and 
moisture penetration by covering it with plastic film for 
instance.

 WARNING

Electronic components become permanently faulty when 
they are exposed to temperatures higher than 60°C. Normal 
AA batteries will crack open at temperatures >54°C and 
the battery contents will damage the electronic switches 
below. Batteries have the longest life span at <25°C. At 
temperatures >50°C this life span will only be approximately 
23 weeks, which would make the use of the gas fireplace 
unnecessarily expensive. 

Only install the gas control block 

and receiver as pre-installed at the factory.

Remember that components may have to be replaced or 
that repairs may have to be performed at a later date. This 
may prove to be more difficult if the control is installed in a 
different way to how we have described in instructions.

Only insert the batteries after the receiver, gas control block 
and pilot light set have been wired.

 Premature connection to 

the power source can damage the electronics. 

Ensure the ignition cable is not near the antenna wire and 
that they do not cross each other.

 The high voltage released 

during ignition may damage the sensitive receiver circuit of the 
antenna. This could mean the unit becomes less responsive or 
totally unresponsive to commands from the handset.

 NOTE

Do not tighten the contact breaker and the thermocouple 
connection too tightly on the gas control block! It is 
sufficient to tighten by hand and add a half a turn with 
an open-end spanner. Tightening too much will break 
the connection to the magnetic coil below and/or the 
insulation around the aluminium contact pin in the contact 
breaker. This may cause the magnetic coil to not open 
the gas supply to the pilot light and prevent the unit from 
functioning.

Prevent leakage of ignition spark to parts of the installation 
other than the ignition rod on the pilot light. Ensure the ignition 
cable is not in contact with the body or other metal parts. 
If a cable extension is used, ensure the connections have 
additional silicone insulation.

The receiver and the control units on the gas control block 
should be switched on to ensure automatic start-up via the 
manual transmitter.
The oval disc on the gas control block should be turned to 
the ON position. The 

I/0

 witch should be set to 

‘I’

. The ignition 

cable should be connected to the 

‘SPARK’

 connection point on 

the receiver box.

The system’s thermostat sensor is located inside the manual 
transmitter.
The manual transmitter operates best at a distance of 2 or 3 
metres away from the unit. Although communication occurs 
via shortwave radio signals, it is recommended that you place 
the hand-held transmitter in the line of sight of the gas unit, 
in a place where the user wishes to experience a pleasant 
temperature. Do not place the manual transmitter in direct 
sunlight or other warm locations. The thermostat measures 
the temperature and, accordingly, regulates the flame size of 
the gas unit.

 NOTE

Sealed parts must not be adjusted, to do so would void 
the warranty.

A waiting time of 5 minutes between each start attempt 
must be observed.

Содержание TL70SL

Страница 1: ...INSTALLATION INSTRUCTIONS FOR MODELS TL70SL ...

Страница 2: ...INSTALLATION INSTRUCTIONS FOR MODEL TL70SL ...

Страница 3: ...TECHNICAL SPECIFICATIONS 11 8 CONCENTRIC PATHWAYS 13 9 CONCENTRIC FLUE SYSTEM 14 9 1 Components of the concentric flue system 14 9 2 Indirect direct façade connection if applicable See Chapter 8 14 9 3 Installation instructions regarding existing flues See Appendix 2 14 9 4 Parts 15 9 5 Installation 15 10 PASS THROUGH POSITIONS AND FUNCTION CORRECTLY 16 11 CLEANING AND MAINTENANCE 17 12 QUICK REFE...

Страница 4: ...fter installation of the unit the glass surface is considered to be an active zone The glass surface can become very hot Note Therefore you should take care by for example keeping children and those requiring help away from the immediate vicinity of burning fires Gas fires must not be placed on or against flammable materials curtains etc Never install the unit against or within a flammable wall NO...

Страница 5: ... the glass pane is important because otherwise the deposit will burn on it and it will not be possible to clean it properly This also applies when working with Black glass wandset and or AR glass Remove the cover frame First remove the frame with glass pane There are then four Allen bolts to be loosened Slide the frame forward to release it 2 3 Installing the unit The unit can now be put into plac...

Страница 6: ...ess to the flue gas outlet is now available There are two Parker screws at the flue gas outlet where the restriction plate can be mounted in case of a longer pathway 70mm restriction Connecting the gas There is a separate removable panel at the front of the unit to ease the installation of the gas pipe The unit has a fixed point to which the gas pipe must be connected There are break plates in the...

Страница 7: ...ce has been technically connected and checked the installation can be completed Replacing the batteries There is a battery holder in the battery box with cover plate This includes 4 x AA batteries When the batteries are fully discharged the cover plate can be disassembled and the batteries replaced NOTE Do not connect a 9 Volt block This will cause the electronics to fail There are 2 AAA batteries...

Страница 8: ...you put the wood set in place 3 1 Mounting instructions for the optional high gloss black glass set 4 INSTALLING THE CERAMIC WOOD SET Place the glow material on the burner Place the ceramic blocks in sequence such as shown in images 1 through 8 NOTE No glow materials on the grid see Figure 1 In Figure 3 the pins are located in the logs Always ensure the pilot light remains free of any material Pin...

Страница 9: ...8 Trimline 70 SL 1 5 2 6 3 7 4 8 Pin Pin ...

Страница 10: ...combustion air inlet Concentric Ø100 Ø150mm Adjustment screw burner pressure Main gas control knob Inlet pressure Outlet pressure Gas exhaust Gas intake Thermocouple connection Piezo connection Adjustment screw burner pilot light Main adjustment Pilot Burner G30 ZP2M Receiver B6R R8 9 P Thermocurrent Cable SW with ON OFF Switch G60 ZSKS L S Thermocurrent Cable TC G60 ZKIRS 8 Wire Cable G6R C Inter...

Страница 11: ... not near the antenna wire and that they do not cross each other The high voltage released during ignition may damage the sensitive receiver circuit of the antenna This could mean the unit becomes less responsive or totally unresponsive to commands from the handset NOTE Do not tighten the contact breaker and the thermocouple connection too tightly on the gas control block It is sufficient to tight...

Страница 12: ...W 2 7 2 8 2 2 2 8 2 8 NOx Hs mg kWh 75 5 83 75 83 83 Efficiency class NE613 1 1 1 1 Useful return NCV system For nominal heat output 83 7 83 7 81 4 83 7 83 7 For minimal heat output 81 3 80 5 79 5 80 5 80 5 Supplementary electricity consumption Nominal kWh 0 0 0 0 Stand by kWh 0 0 0 0 Energy efficiency Energy efficiency index EEI 78 77 8 75 77 8 77 8 Energy label C C D C C NOx Hi class 5 5 5 5 Hea...

Страница 13: ...1 1 Useful return NCV system For nominal heat output 82 4 82 4 For minimal heat output 77 5 77 5 Supplementary electricity consumption Nominal kWh 0 0 Stand by kWh 0 0 Energy efficiency Energy efficiency index EEI 76 3 76 3 Energy label C C NOx Hi class 5 5 Heat output type room temperature control Indirect heat functionality No Single stage heat release no room temperature control No 2 or more ma...

Страница 14: ... slope D 3 9 0 4 from X total Y 6 metres 50mm Roof pass through with 90º slope E 3 9 0 2 from X X1 Y 6 metres 50mm 45 bend calculation length 1 metres 90 bend calculation length 2 metres length including roof or exterior wall outlets Always adhere to a starting length of 1 metre Ratio vertical horizontal X X1 X2 Y 2 1 Ration vertical horizontal X X1 Y 2 1 Restriction provisions all gas types Verti...

Страница 15: ... a non fire resistant façade The flue should be encased if necessary Even if the flue is to be installed along non refractory materials sufficient fire resistant measures must be taken Determine the position of the unit and outlet and begin construction of the flue with the connection on the unit paying attention to the direction of installation and connecting the elements by means of clamp strips...

Страница 16: ...o the flexible hose on the roof 8 clamp it with a hose bracket Stainless steel round 90 to 165 secure the whole with Parker screws Attach the mounting plate to the chimney coping watertight on the roof 8 using silicone sealant and stainless steel screws Install the roof pass through 9 and secure it in place using the supplied clamping strip 10 The slider 5 will protrude approximately 100mm underne...

Страница 17: ...tlet pipes below here 500 E Under the eaves 500 F Under a carport roof or balcony inside and outside corners 500 G From vertical ground pipes or drain pipes 300 H Inside and outside a corner 500 I Above an external gas pressure regulator 1000 Side of a gas pressure regulator 500 J Conflict distance façade outlet Room K Roof drain centre to centre 1000 L From the centre of both roof drains 450 M Tw...

Страница 18: ...urner support on the left is then visible There is a Parker screw here Partly loosen it and then slide the burner to the left The glow material can therefore remain on the burner We see the base upon which the technical equipment is located There are Parker screws on the outer edge These must be unscrewed the base plate can then be removed Left side up first and then remove the entire thing with a...

Страница 19: ...is access has been made available to aid checking the pre pressure and the burner pressure after installation The burners are tuned and sealed by the factory If a correction is necessary the burner base will have to be disassembled in order to reach the adjusting screw Explosion hatch Thermocouple Adjustment screw burner pressure ...

Страница 20: ...frame with glass pane See Paragraph 2 2 Preparation and placement on page 3 Important After the first use there will be a white haze on the inside of the glass pane this white haze must be removed immediately after the first use when the unit has cooled down The higher the frequency of use the more often cleaning is required After more frequent use more frequent cleaning of the glass will be neces...

Страница 21: ...for fractures replace if necessary Distance of sparkling candle to pilot light head Check distance is approximately 4mm 6 Pilot light difficult to ignite Gas supply pressure too high nervous flame Adjust gas supply pressure or adjust the pilot light pressure using the gas valve Gas supply pressure too low short flame Adjust gas supply pressure check gas pipes or adjust pilot light pressure using t...

Страница 22: ...gs Check and clean with a vacuum cleaner or similar device Logs etc in wrong position Check and correct see instructions 12 Low main flame Gas supply pressure too low Check gas supply pressure and corrections Burner pressure too low Check burner pressure check instructions for correct values 13 No or little difference between high low settings for main flame Low position setting incorrect Check an...

Страница 23: ...22 Trimline 70 SL 629 406 706 931 88 134 17 546 661 155 177 195 673 100 150 839 Appendix 1 DIMENSIONAL DRAWINGS ...

Страница 24: ...ate flat K Floor support F Floor support Material Stainless steel AISI 316 L Allow number 1 4404 Diameter inner pipe outer pipe Ø 100mm Ø 150mm Application for the discharge of flue gases and the supply of combustion air from gas fired fireplaces or stoves with a closed combustion system 8 Chimney mounting plate Renovation package 7 Existing flue 9 Clamping strap 10 Roof pass through 1 Clamping st...

Отзывы: