background image

 

Technical Data 

 

Technical Manual 

Version 1.5 

 

4.1 

Dimensions (mm) 

 

X = 620 

  

4.2 

Pin Assignment 

 

 

M12 Male-Connector 4pin       
A-Coded 

  

Pin 

Signal 

Colour of Conductor 

+24 VDC 

brown 

— 

white 

0 V (GND) 

blue 

EXT 

black 

  

  

4.3 

Settings 

 

 

  

Switch Position 

Setting (MODE) 

internal dimming (Poti) 

luminosity fix 

external control 

  

  

Содержание 08K0008A

Страница 1: ...Technical Manual MDL600 LED module light white diffuse Article No 08K0008A Version 1 5 ...

Страница 2: ...se Systeme GmbH Heinrich Hertz Straße 7 68753 Waghäusel Germany Tel 49 7254 9351 0 Fax 49 7254 9351 200 www vision tools com info vision tools com Revision date April 2019 Version 1 5 Version change Attachment Technical data ...

Страница 3: ...ility 4 2 6 Copyright law 4 2 7 Guarantee and Liability 4 3 Safety 5 3 1 Appropriate use 5 3 2 Foreseeable misuse 5 4 Technical Data 6 4 1 Dimensions mm 7 4 2 Pin Assignment 7 4 3 Settings 7 5 Commissioning 8 5 1 Initial operation 8 5 2 Return to service 8 5 3 Assembly 9 6 Maintenance and repair 10 6 1 Recommended Spare Parts 10 7 Product versions 10 8 Disposal 11 9 Notes 12 10 Attachment 13 10 1 ...

Страница 4: ...nd instructions are to be carefully read before use The manual is a product component and must be kept accessible to the plant operator at all times 2 3 Documents enclosed Declaration of Conformity 2 4 Safety information In this manual icons acc to EN ISO 7010 are used to highlight correct text passages and relevant sections If the product is sold in a non EU country the warning symbols may need t...

Страница 5: ...ions In accordance with DIN EN ISO 7010 General warning sign In accordance with DIN EN ISO 7010 Warning of electrical voltage In accordance with DIN EN ISO 7010 Warning of hot surface In accordance with DIN EN ISO 7010 Warning of oxidising substances In accordance with DIN EN ISO 7010 ...

Страница 6: ... includes regulations and information that may not be duplicated distributed or transmitted in any other manner either in whole or in part Duplicating the manual within a company for the purposes of training by the operator is excepted Violations may have criminal consequences 2 7 Guarantee and Liability Our General Terms and Conditions apply Claims for a guarantee or for liability in case of pers...

Страница 7: ...will bear sole responsibility for any damages that may result from such use the company VisionTools accepts no liability In case of changes or unauthorized modifications to the system any liability or guarantee from VisionTools Bildanalyse Systeme GmbH will cease to exist The electromagnetic behaviour of the system can be impaired by additions or changes of any kind Therefore make no changes or ad...

Страница 8: ...A Power consumption 52 W Dimming external 0 10 V Dimming internal 0 100 Dimming fix 95 Trigger external 10 30 V Trigger Current approx 6 mA Perm ambient temperature 10 50 C Protection type IP40 Mean time between failures MTBF 100000 h Life span typ max 50000 h Luminous efficiency after 100h 98 Luminous efficiency after 50000h 95 Luminous efficiency after 100000h 90 Connection M12 Male Connector 4p...

Страница 9: ...imensions mm X 620 4 2 Pin Assignment M12 Male Connector 4pin A Coded Pin Signal Colour of Conductor 1 24 VDC brown 2 white 3 0 V GND blue 4 EXT black 4 3 Settings Switch Position Setting MODE 1 internal dimming Poti 2 luminosity fix 3 external control ...

Страница 10: ...rating voltage can be found in chapter Technical Data The MDL glows continuously because the slider is in the delivery status is at the second position see Settings 5 2 Return to service Specifically the following points should be noted The setting of the slide switch see Settings If necessary the surface of the MDL should be cleaned with a dry cloth to eliminate dust and other dirt ...

Страница 11: ... the help of slot nuts In order to rotate an MDL with a flange clamping piece by 90 it is advisable to install a dedicated adapter plate between the MDL and the flange clamping piece Fig 1 Flange clamping piece FK18 Fig 2 Aluminium joint 8 40x40 Fig 3 Adapter plate 90 for FK18 NOTE It is recommended that for MDLs with sizes larger than 300mm either two flange clamping pieces or two aluminium joint...

Страница 12: ...lange clamp FK 18 10A0008B Flange clamp FK 18 with elongated hole 08K0101A Adapter plate 90 for FK18 09E0003B Power cabel M12 4pos female connector 5m open end 09E0003C Power cabel M12 4pos female connector 10m open end 09E0003E Power cabel M12 4pos female connector 15m open end 09E0003D Power cabel M12 4pos female connector 20m open end 09E0003F Power cabel M12 4pos female connector 25m open end ...

Страница 13: ...collection stations Your responsible administrative authority can give you more specific information on where authorized collection stations can be found NOTE Observe national regulations and internal operational solutions Dispose of the packaging of production materials including in the product cycle of the system appropriately Ensure appropriate separation and disposal ...

Страница 14: ...Notes Technical Manual Version 1 5 12 9 Notes ...

Страница 15: ...Attachment Technical Manual Version 1 5 13 10 Attachment 10 1 Declaration of conformity Konformitätserklaerung ...

Страница 16: ......

Отзывы: