TVP-B/TVP-P Price Computing Scales Operation Manual
- 8 -
14. PARAMETER
PARAMETER SETTING
Enter into the Menu
Turn on the scale. Press and hold
key during the self test.
Display will show
“
Pn
”
briefly PIN is activated. Press the PIN number to get
into the parameter menu.
The default PIN number is “0000”
Press numeric key 0 four times , display will be shown
Pn - - - -
Press
key to confirm, It will enter into the parameter settings and will to show
“
menu unit kg
”
.
Enter to Selected Menu
Press
, it can confirm which will be shown displayed.
Select the Menu
Press
or
. It can choose menu block one by one.
Return to Weighing Mode
Press
escape from the menu and exit to weighing mode
Active Parameter
F11 rS232
ModE
PC-100
Protocol Type :CAS
printr
The scale RS232 protocol will be
determined by the Baud & Pr settings
EP50
accumulation
function
enable,and
press M+ key to send data to receipt
printer
Lp50
accumulation function enable, and press
M+ key to send data to printer
POS
Protocol Type :POS
oFF
RS232 function disable
Cont
Continues data transmission
StC
Stable data sending continues
Toledo
Protocol Type 1: Toledo
nciecr
Protocol Type 2: NCI-ECR